(2)
AMM 24-22-00/201, Manual Control
(3)
WDM 21-31-13, WDM 21-31-21, WDM 21-31-22
(4)
SSM 21-31-02, SSM 21-31-04
D. Access
(1) Location Zone
151 Area Aft of Bulk Cargo Compartment, LH
152 Area Aft of Bulk Cargo Compartment, RH
E. Procedure
S 824-014
(1) Put the outflow valve assembly (1) in its position on the skin opening.
EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. ú
21-31-01
ALL ú ú 01 Page 405 ú Oct 18/00
BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details.
A
747-400
MAINTENANCE MANUAL
S 434-035
(2) Install the washers (11) and bolts (10). Tighten the bolts by hand.
S 824-015
(3) From outside of the airplane, make a mark on the outflow valve frame at each bolt hole location. Make a mark on the outflow valve frame in 24 locations for the 1/4-inch holes and in 8 locations for the 5/16-inch holes.
S 324-016
(4) Remove the outflow valve assembly (1) from the airplane and drill the holes for the 1/4-inch (6.4 mm) and the 5/16-inch (8 mm) bolts.
S 394-017
(5) Apply the sealant to the outflow valve frame and the skin mating surfaces.
S 424-018
(6) Put the outflow valve assembly in its position on the skin opening.
S 434-019
(7) Install the 24 bolts (15), washers (16), and nuts (17).
S 434-020
(8) Install the 8 bolts (12), washers (13), and nuts (14).
S 434-021
(9) Attach the gearcase to the bracket with the bolts (10) and washers (11).
S 434-022
(10) Attach the bonding jumper (6) to the structure with the screw (7), washer (8) and nut (9).
S 434-023
(11) Install the electrical connectors (3, 4, and 5) on the valve (1).
(a) The DC motor electrical connector (3),
DV90C-right or DV91C-left
(b) The AC motor electrical connector (4),
DV90A-right or DV91A-left
(c) The position potentiometer electrical connector (5),
DV90B-right or DV91B-left.
S 414-025
(12) Install the safety screen (2). Make sure the actuator arm is free of the safety screen.
EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. ú
21-31-01
ALL ú ú 03 Page 406 ú Jun 18/00
BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details.
A
747-400 MAINTENANCE MANUAL
S 864-026
(13) Remove the DO-NOT-CLOSE tags and close these circuit breakers:
(a)
P6 Main Power Distribution Panel
1) 6J28 CABIN PRESS AUTO A
2) 6J29 CABIN PRESS AUTO B
3) 6J30 CABIN PRESS CONT L ICU
4) 6J31 CABIN PRESS CONT R ICU
5) 6L6 CABIN PRESS MAN L
6) 6L7 CABIN PRESS MAN R
(b)
P414 Main Power Distribution Panel
1) 414M8 CABIN PRESS ICU LEFT
2) 414B8 CABIN PRESS ICU RIGHT
(c)
P83 in aft equipment center
1) OUTFLOW VALVE-R
2) OUTFLOW VALVE-L
S 864-027
(14)
Apply electrical power (AMM 24-22-00/201).
S 864-033
(15)
中国航空网 www.aero.cn
航空翻译 www.aviation.cn
本文链接地址:747-400 AMM 飞机维护手册 空调 AIR CONDITIONING 1(114)