(2)
Make sure that a warning notice is in position in the cockpit to tell persons not to operate the emergency oxygen system.
(3)
Make sure that the access platform is in position at the AFT cargo-compartment door 826.
(4)
Make sure that the AFT cargo-compartment door 826 is open (Ref. TASK 52-30-00-860-001).
(5)
Make sure that the CARGO COMPT LIGHT switch 8LU is in the ON position.
(6)
Make sure that the related lining panel is removed (Ref. TASK 25-55-12-000-003).
(7)
Make sure that the manual shut-off valves of the emergency oxygen cylinders are close.
(8)
Obey the special precautions when you do this task (Ref. TASK 35-00-00-860-001).
Subtask 35-22-65-865-051
B. Make sure that this(these) circuit breaker(s) is(are) open, safetied and tagged
-------------------------------------------------------------------------------PANEL DESIGNATION IDENT. LOCATION -------------------------------------------------------------------------------49VU OXYGEN/PASSENGER/CTL AND WARN 2WR HA03 49VU OXYGEN/PASSENGER/CTL AND WARN 1WR HA02
4. Procedure
_________
WARNING : KEEP ALL HYDROCARBONS (FUELS, LUBRICANTS, ETC.) AWAY FROM ALL
_______
SOURCE OF OXYGEN. OXYGEN BECOMES EXPLOSIVE WHEN IT TOUCHES
HYDROCARBONS.
WARNING : CLEAN THE TOOLS AND MAKE SURE YOUR HANDS ARE CLEAN TO PREVENT
_______
CONTAMINATION OF THE OXYGEN SYSTEM.
Subtask 35-22-65-420-050
A. Installation of the Oxygen Test Port (7504WR1/7504WR2)
(Ref. Fig. 401/TASK 35-22-65-991-001)
(1)
Do an inspection of the component interface and/or the adjacent area.
(2)
Remove the vinyl bags from the disconnected line ends.
(3)
Remove the blanking plugs from the disconnected line ends.
(4)
Put the oxygen test port (1) in position and tighten the nut (2) with your fingers.
(5)
TORQUE the nut (2) to between 1.92 and 2.03 m.daN (14.15 and 14.97 lbf.ft).
NOTE : You must hold the fitting tightly in the correct position.
____ Subtask 35-22-65-865-052
B. Remove the safety clip(s) and the tag(s) and close this(these) circuit breaker(s): 1WR, 2WR.
Subtask 35-22-65-790-050
C. Do these tests
(1)
FOR 7504WR1
Do this leakage check (Ref. TASK 35-23-00-790-001).
(2)
FOR 7504WR2
Do this leakage check (Ref. TASK 35-23-00-790-002).
Subtask 35-22-65-614-051
D. Pressurize the Emergency Oxygen System
(1)
Slowly open the manual shut-off valves of the emergency oxygen cylinders 3.5 to 4 turns.
(2)
Let the pressure become stable.
NOTE : This occurs after approximately 90 seconds.
____
(3)
Fully open the manual shut-off valves of the emergency oxygen cylinders.
(4)
If necessary, fill the emergency oxygen cylinders (Ref. TASK 35-21-00-614-002).
Subtask 35-22-65-942-050
E. Remove the warning notice(s).
5. Close-up
________ Subtask 35-22-65-410-050
A. Close Access
(1)
Make sure that the work area is clean and clear of tool(s) and other items.
(2)
Install the related lining panel to close access to the oxygen storage (Ref. TASK 25-55-12-400-003).
(3)
Set the CARGO COMPT LIGHT switch 8LU to the OFF position.
(4)
Remove the access platform(s).
(5)
Close the AFT cargo-compartment door 826 (Ref. TASK 52-30-00-860-002).
Subtask 35-22-65-862-050
B. De-energize the aircraft electrical circuits
(Ref. TASK 24-41-00-862-002).
TASK 35-22-65-000-002
Removal of the Oxygen Test Port (7504WR3)
1.
Reason for the Job
__________________
Self Explanatory
2.
Job Set-up Information
______________________
A. Fixtures, Tools, Test and Support Equipment
-------------------------------------------------------------------------------REFERENCE QTY DESIGNATION -------------------------------------------------------------------------------
No specific circuit breaker(s) safety clip(s) No specific 1 BAG - VINYL No specific 1 PLUG - BLANKING No specific 1 WARNING NOTICE