 F. Failure Indications on the POXIP
 The indication 'CYLINDER FAULT' comes on:
 -
When the manual shut-off valve of a minimum of one cylinder assemby is not fully open.

 The indication 'REGUL LO PR' comes on:

 -
When the pressure in the intermediate line is too low.

 -
When the low pressure switch does not operate.


 The indication 'REGUL SYS1' and 'REGUL SYS2' come on:
 -There is no electrical power supply.
 -
The signal OPEN is active and the oxygen regulator is fully closed.

 -
The signal OPEN is not active and the oxygen regulator is not fully closed.


 -There is an internal error of the oxygen regulator.
 The indication 'CHECK' comes on:
 -
When the pressure in the cylinder assembies is less than 1600 psi (110.3161 bar).

 The indication 'LO' comes on:

 -
When the pressure in the cylinder assembies is less than 200 psi (13.7895 bar).


 7. Ground Test
___________
 The quantity calculation and control unit 960WR has a power up test and a continuous test. It checks:
 -
The pressure transmitters


 -
The temperature transducer 975WR


 -
The QCCU 960WR.
 There is a warning light on the QCCU for each of the faults. The related
 light (PRESSURE, COMPUTER OR TEMPERATURE) comes on when a fault occurs.
 If the fault is corrected, the light stays on until the QCCU is reset or the
 power is switched off.
 The QCCU 960WR has a 'TEST' pushbutton to make the lighttest on the unit.

 

 NOTE : Before you do a test, you must pull out the door-stops and turn them
____ through 90 degrees. This makes sure that the oxygen masks do not fall out.


 To make sure that a door latch assembly releases the door you can do a
 ground test with the manual release tool.
 To make sure that the pneumatic latches operates correctly you can do a
 functional test with the MAN ON pushbutton switch.
 After a functional test you must also release the pressure from the system
 through the bleed/vent valve.
 After a test you must close the doors turn the door-stops through 90 degrees
 and release them.
 After a functional test you must push the 'RESET' pushbutton switch to set
 the system back to normal.

 

 CONTROL AND INDICATING - DEACTIVATION/REACTIVATION__________________________________________________
 TASK 35-23-00-040-001
 Check of the MAN MASK pushbutton when the HI ALT system does not operate
 1. Reason for the Job__________________
 Refer to the MMEL TASK: 35-23-01-C)a) Passenger Oxygen Control and Indicating HI ALT LANDING Pb Sw High Altitude Control
 2. Job Set-up Information______________________
 A. Fixtures, Tools, Test and Support Equipment
 -------------------------------------------------------------------------------REFERENCE QTY DESIGNATION -------------------------------------------------------------------------------
R  No specific No specific 98A35207599000  vacuum source 1 ACCESS PLATFORM 3M (10 FT)- ADJUSTABLE2 HOSE - ADAPTER, ALTITUDE SWITCH
 B. Referenced Information
 -------------------------------------------------------------------------------REFERENCE DESIGNATION -------------------------------------------------------------------------------
R  24-41-00-861-002 24-41-00-862-002 35-23-15-000-001  Energize the Aircraft Electrical Circuits from the External PowerDe-energize the Aircraft Electrical Circuits Supplied from the External Power Removal of the Altitude Switch (16WR) 
R  **ON A/C 401-499, 
R  35-23-00-991-006  Fig. 401 

R EFF : 052-055, 057-057, 401-499, 35-23-00Page 401

 

R  **ON A/C 052-055, 057-057, 401-499,
 3. Job Set-up__________
 Subtask 35-23-00-865-058
 A. Make sure that this(these) circuit breaker(s) is(are) closed:
 -------------------------------------------------------------------------------PANEL DESIGNATION IDENT. LOCATION -------------------------------------------------------------------------------49VU OXYGEN/PASSENGER/ACTUATION 7WR HA08 49VU OXYGEN/PASSENGER/ACTUATION 6WR HA07 49VU OXYGEN/PASSENGER/ACTUATION 5WR HA06 49VU OXYGEN/PASSENGER/ACTUATION 4WR HA05 49VU OXYGEN/PASSENGER/CTL AND WARN 3WR HA04 49VU OXYGEN/PASSENGER/CTL AND WARN 2WR HA03 49VU OXYGEN/PASSENGER/CTL AND WARN 1WR HA02 
R  **ON A/C 401-499, 
R  Subtask 35-23-00-865-061 
R  B. Make sure that this(these) circuit breaker(s) is(are) closed: 
 
中国航空网 www.aero.cn