 The 'ON' light of the 'TMR RESET' pushbutton switch 13WR on the maintenance panel 50VU does not go off if:
 -The electrical circuit for the oxygen system does not reset to the correct condition.
 The 'REGUL SYS 1' and/or 'REGUL SYS 2' indicator light on the POXIP come(s) on if:


 -the oxygen regulator 910WR1 and/or the oxygen regulator 910WR2 is/are defective.
 An internal pressure sensor integrated in the oxygen regulators operates the 'SYS ON' indicator light 12WR. If the pressure in the system decreases less than 0.045 bar (0.65 psi) the 'SYS ON' indicator light 12WR goes off. If no masks are pulled, a max. time of 25 minutes is necessary to decrease the pressure of the system.
 The 'REGUL SYS 1' and/or 'REGUL SYS 2' indicator light on the POXIP come(s) on if:
 -the oxygen regulator 910WR1 and/or the oxygen regulator 910WR2 is/are defective.


 OXYGEN STORAGE - DESCRIPTION AND OPERATION
__________________________________________
 1. General_______
 The passenger oxygen is supplied from chemical oxygen generators that are installed in emergency oxygen containers. The emergency oxygen containers are installed:
 -above the passenger seats,
 -at the cabin attendant stations,
 -in the lavatories,
 -at the cabin attendant working areas.
 2. Component Location__________________
 -------------------------------------------------------------------------------FIN | FUNCTIONAL DESIGNATION | PANEL|ZONE|ACCESS | ATA | | | | DOOR | REF. -------------------------------------------------------------------------------Oxygen Container 200 35-23-00
 3. Component Description_____________________
 **ON A/C 001-049, 051-099, 101-149, 151-199, 211-299, 301-399,
 **ON A/C 001-049, 051-061, 101-105, 151-199, 301-399,
 (Ref. Fig. 001)
 **ON A/C 062-099, 106-149, 211-299,
 (Ref. Fig. 001A)
 **ON A/C 001-049, 051-099, 101-149, 151-199, 211-299, 301-399,
 (Ref. Fig. 002)


 Emergency Oxygen Container - Stowed

 Figure 001
 EFF :  001-049, 051-061, 101-105, 151-199, 35-21-00 Page 2 
201-207, 301-399,  Config-1 Aug 01/05
 CES 

 

 Emergency Oxygen Container - Stowed
 Figure 001A

 CES


 Chemical Oxygen Generator

 Figure 002
 EFF :  001-049, 051-099, 101-149, 151-199, 35-21-00 Page 4 
201-299, 301-399,  Config-1 Aug 01/05
 CES 

 

 A. Emergency Oxygen Container
 (1) Chemical Oxygen Generator The chemical oxygen generator is a sodium-chlorate core installed in a stainless-steel housing. A thermal insulating material is used between the core and the housing. The actuator of the chemical generator is a spring-loaded striker and a percussion cap installed at one end of the housing. A release pin holds the striker away from the cap. A lanyard connects the release pin to the oxygen mask. A filter assembly is installed in the outlet end of the housing to prevent the contamination of the oxygen supply. A flexible hose connects the oxygen mask to the outlet manifold and the outlet valve supplies oxygen to the oxygen mask. The outlet is installed on the housing. A relief valve is installed at the outlet end of the housing. This will prevent a high-pressure build-up, if a failure of the outlet valve occurs. An indicator on the housing will change color (from yellow to black) when the chemical oxygen generator is used and the generator is not more usable.
 **ON A/C 201-210,
 **ON A/C 201-207,
 (Ref. Fig. 001)
 **ON A/C 208-210,
 (Ref. Fig. 001A)
 **ON A/C 201-210,
 (Ref. Fig. 002) A. Emergency Oxygen Container


 (1) Chemical Oxygen Generator The chemical oxygen generator is a sodium-chlorate core installed in a stainless-steel housing. A thermal insulating material is used between the core and the housing. The actuator of the chemical generator has a spring-loaded striker and a percussion cap installed at one end of the housing. A release pin holds the striker away from the cap. A lanyard connects the release pin to the oxygen mask. A filter assembly is installed in the outlet end of the housing to prevent the contamination of the oxygen supply. A flexible hose connects the oxygen mask to the outlet manifold supplies oxygen to the oxygen mask. The outlet is installed on the housing. A relief valve is installed at the outlet end of the housing. This will prevent a high-pressure build-up, if a failure of the outlet valve occurs. An indicator on the housing will change color (from pink to blue) when the chemical oxygen generator is used and the generator is no more useable.