No specific vacuum source 98A35207599000 1 HOSE - ADAPTER, ALTITUDE SWITCH
 B. Referenced Information
 -------------------------------------------------------------------------------REFERENCE DESIGNATION -------------------------------------------------------------------------------
23-73-00-861-001 Energize the Cabin Intercommunication Data System (CIDS) 24-41-00-861-002 Energize the Aircraft Electrical Circuits from the External Power 24-41-00-862-002 De-energize the Aircraft Electrical Circuits Supplied
 from the External Power 35-21-00-920-001 Discard Oxygen Generators 35-21-41-000-001 Removal of the Emergency Oxygen Containers 35-21-41-400-001 Installation of the Emergency Oxygen Containers 35-23-00-550-001 Packing of the Oxygen Masks


 3. Job Set-up__________ 
R  **ON A/C 001-049, 051-099, 101-105, 151-199, 201-299, 301-399,
 Subtask 35-23-00-860-050
 A. Aircraft Maintenance Configuration
 (1) Energize the aircraft electrical circuits (Ref. TASK 24-41-00-861-002).
 (2) Energize the CIDS system (Ref. TASK 23-73-00-861-001). 
R  **ON A/C 106-149, 
R  Subtask 35-23-00-860-050-B 
R  A. Aircraft Maintenance Configuration 
R R  (1) Energize the aircraft electrical circuits (Ref. TASK 24-41-00-861-002). 
R  **ON A/C 001-049, 051-099, 101-149, 151-199, 201-299, 301-399,
 Subtask 35-23-00-865-054
 B. Make sure that this(these) circuit breaker(s) is(are) closed:
 -------------------------------------------------------------------------------PANEL DESIGNATION IDENT. LOCATION -------------------------------------------------------------------------------49VU OXYGEN/PASSENGER/ACTUATION 7WR HA08 49VU OXYGEN/PASSENGER/ACTUATION 6WR HA07 49VU OXYGEN/PASSENGER/ACTUATION 5WR HA06 49VU OXYGEN/PASSENGER/ACTUATION 4WR HA05 49VU OXYGEN/PASSENGER/CTL AND WARN 3WR HA04 49VU OXYGEN/PASSENGER/CTL AND WARN 2WR HA03 49VU OXYGEN/PASSENGER/CTL AND WARN 1WR HA02

 

R  **ON A/C 001-049, 051-099, 101-105, 151-199, 201-299,
 Subtask 35-23-00-865-055
 C. Make sure that this(these) circuit breaker(s) is(are) closed:
 -------------------------------------------------------------------------------PANEL DESIGNATION IDENT. LOCATION -------------------------------------------------------------------------------2000VU CAB COM SYSTEM - PRAM 2RX 07 F 
R  **ON A/C 001-049, 051-099, 101-149, 151-199, 201-299, 301-399,
 Subtask 35-23-00-010-052
 D. Get Access to the Avionics Compartment
 (1) Open the access doors 812 and 824.
 Subtask 35-23-00-480-052
 E. Connect a Vacuum Source
 (1) Connect the vacuum source to the altitude pressure switch 16WR with the HOSE - ADAPTER, ALTITUDE SWITCH (98A35207599000).
 4. Procedure_________
 **ON A/C 001-049, 051-061, 101-105, 151-154, 201-207, 301-399,
 Subtask 35-23-00-210-054-A 
R R  A. Detailed Inspection of Masks and Visual Check of Chemical Oxygen Generators
 CAUTION : DO NOT PULL THE GENERATOR-END OF THE LANYARD._______
 (1) Remove the oxygen container from its position (Ref. TASK 35-21-41-000-001). 
R R  (2) Push the test lever back to the initial position and open all emergency-oxygen container doors.

 

R  (3) Examine the chemical oxygen generators: 
R  (a) Make sure that: - The condition indicator is yellow.
 NOTE : A replacement of the chemical oxygen generator is____ necessary, if the condition indicator is black (Ref. TASK 35-21-00-920-001).
 - There are no damages, corrosion, cracks or tension on the outlet fittings. 
R R R R  (b) Serviceability check of the oxygen generator: - Read the manufacturing date on the label of the oxygen generator. - Obey the manufacturer's instructions.
 (4) Examine the oxygen masks: - For cracks - For color changes - For dirt.
 (5) Examine the flexible supply hoses: - For correct attachment to the reservoir bag and the generator - For kinks - For color changes.
R  (6) Examine the reservoir bags: - For correct connection to the mask and the supply hoses - For tears - If you can read the inscription.
 (7) Examine the elastic head band: - For over extension - For elasticity - For correct attachment to the mask. 
R  (8) Do a check of the lanyards:
 CAUTION : DO NOT PULL THE GENERATOR-END OF THE LANYARD._______
R R  - Give the lanyard to mask connection a strong, short pull to make sure that the connection is satisfactory. - Make sure that the lanyards are free and do not catch any part in the emergency oxygen container.

 

R  (9) Close the door of the emergency oxygen container: 
 