-the oxygen HP indication stays green.
4. On the panel 21VU: On the DOOR/OXY page:
-push the OXYGEN/CREW SUPPLY - the REGUL LO PR indication is not pushbutton switch. shown,
-The OFF legend goes off. - OXY changes from amber to green,
-the oxygen HP indication stays green.
5. On the panel 21VU: - the OFF legend comes on.
-release the OXYGEN/CREW SUPPLY
pushbutton switch.
R **ON A/C 106-149, 303-399, 401-499,
Subtask 35-12-00-710-050-A
A. Operational Test
(1) On the lower ECAM display unit, the DOOR/OXY page is shown automatically on the ground unless there is a failure in another aircraft system. If there is a failure: - on the ECAM control panel, on the center pedestal, push the DOOR
key, the DOOR/OXY page is shown with the oxygen indication.
If the pressure is less than 1500 PSI a half box (advisory) is
shown only for information.
Do not do this test if the HP oxygen pressure is less than 400 PSI,
or if the HP information is not available (XXXXPSI). In this
condition, do a trouble shooting procedure (Ref. TSM 35 PB 101).
EFF : ALL
35-12-00Page 503
R (2) Do this test:
R -------------------------------------------------------------------------------R ACTION RESULT R -------------------------------------------------------------------------------
R 1. On the panel 21VU:
R - push the OXYGEN/CREW SUPPLY
R pushbutton switch.
R The OFF legend goes off.
R 2. On the panel 21VU:
R - release the OXYGEN/CREW SUPPLY
R pushbutton switch.
R The OFF legend comes on.
R 3. In the cockpit, on one of the
R oxygen mask stowage-boxes :
R - push the PRESS TO TEST AND
R RESET control slide many times.
R
R 4. On the panel 21VU:
R - push the OXYGEN/CREW SUPPLY
R pushbutton switch.
R - The OFF legend goes off.
R
R 5. On the panel 21VU:
R - release the OXYGEN/CREW SUPPLY
R pushbutton switch.
R **ON A/C ALL
5. Close-up________
Subtask 35-12-00-860-051
On the DOOR/OXY page:
-OXY is shown white
-the oxygen HP indication stays green.
On the DOOR/OXY page:
-OXY changes from white to amber
-
the oxygen HP indication stays green.
On the DOOR/OXY page:
-
the REGUL LO PR message is shown amber
-OXY stays amber
-
the oxygen HP indication stays green.
On the DOOR/OXY page:
-
the REGUL LO PR indication is not shown
-OXY changes from amber to white
-
the oxygen HP indication stays green.
-
the OFF legend comes on.
A. Put the aircraft back to its initial configuration.
(1)
De-energize the aircraft electrical circuits (Ref. TASK 24-41-00-862-002)
(2)
Do the EIS stop procedure (Ref. TASK 31-60-00-860-002).
EFF : ALL
35-12-00Page 504
Feb 01/05
MASK - FULL FACE/QUICK DONNING, OXYGEN (10RN1,10RN2,10RN3,5757HM,5758HM,5759HM,
_______________________________________________________________________________
5760HM,5774HM) - REMOVAL/INSTALLATION_____________________________________
TASK 35-12-41-000-001
Removal of the Oxygen-Mask Stowage-Box
WARNING : KEEP ALL HYDROCARBONS (FUELS, LUBRICANTS, ETC.) AWAY FROM ALL SOURCE_______ OF OXYGEN. OXYGEN BECOMES EXPLOSIVE WHEN IT TOUCHES HYDROCARBONS.
WARNING : CLEAN THE TOOLS AND MAKE SURE YOUR HANDS ARE CLEAN TO PREVENT_______ CONTAMINATION OF THE OXYGEN SYSTEM.
CAUTION : PUT DRY, CLEAN, METAL OR PLASTIC PLUGS ON ALL PIPES OR UNITS REMOVED_______ TEMPORARILY. PUT EACH PIPE OR UNIT IN A SEALED VINYL BAG.
1. Reason for the Job__________________
Self Explanatory
2. Job Set-up Information______________________
A. Fixtures, Tools, Test and Support Equipment
-------------------------------------------------------------------------------REFERENCE QTY DESIGNATION -------------------------------------------------------------------------------
RR R R R R No specific No specific No specific No specific No specific No specific circuit breaker(s) safety clip(s) 1 ACCESS PLATFORM 2M (6 FT) 1 BAG - VINYL 1 CAP - BLANKING 1 PLUG - BLANKING 1 WARNING NOTICE
中国航空网 www.aero.cn
航空翻译 www.aviation.cn
本文链接地址:A320飞机维护手册 AMM OXYGEN 氧气(36)