(2)
Put the access platform below the AFT cargo-compartment door 826.
(3)
Set the CARGO COMPT LIGHT switch 8LU to the ON position.
(4)
Remove the related lining panel to get access to the oxygen storage (Ref. TASK 25-55-12-000-003).
Subtask 35-23-55-614-050
E. Depressurize the Emergency Oxygen System
(1)
Close the manual shut-off valves of the emergency oxygen cylinders.
(2)
Put the TEST TOOL - MANUAL RELEASE on the oxygen test port 7504WR1 to release the pressure from the system.
4. Procedure
_________
WARNING : KEEP ALL HYDROCARBONS (FUELS, LUBRICANTS, ETC.) AWAY FROM ALL
_______
SOURCE OF OXYGEN. OXYGEN BECOMES EXPLOSIVE WHEN IT TOUCHES
HYDROCARBONS.
WARNING : CLEAN THE TOOLS AND MAKE SURE YOUR HANDS ARE CLEAN TO PREVENT
_______
CONTAMINATION OF THE OXYGEN SYSTEM.
CAUTION : PUT DRY, CLEAN, METAL OR PLASTIC PLUGS ON ALL PIPES OR UNITS
_______ REMOVED TEMPORARILY. PUT EACH PIPE OR UNIT IN A SEALED VINYL BAG.
Subtask 35-23-55-860-050
A. Obey the special precautions when you do this task (Ref. TASK 35-00-00-860-001).
Subtask 35-23-55-020-050
B. Removal of the Pressure Relief Valve (7000WR)
(Ref. Fig. 401/TASK 35-23-55-991-001)
(1)
Loosen the nuts (2) and (4) and disconnect the hoses (1) and (3).
(2)
Put PLUG - BLANKING on the disconnected line ends.
(3)
Put the disconnected line ends into a sealed BAG - VINYL.
(4)
Record the location of the bonding screw.
(5)
Remove the screws (5), the washers (6) and carefully remove the pressure relief valve (7).
Pressure Relief Valve (7000WR)
Figure 401/TASK 35-23-55-991-001
EFF : 401-499, 35-23-55 Page 404
Aug 01/05
CES
TASK 35-23-55-400-001
Installation of the Pressure Relief Valve (7000WR)
1. Reason for the Job
__________________
Self Explanatory
2. Job Set-up Information
______________________
A. Fixtures, Tools, Test and Support Equipment
-------------------------------------------------------------------------------REFERENCE QTY DESIGNATION
-------------------------------------------------------------------------------
No specific access platform 1.6 m (5 ft. 3 in.)
No specific Torque Wrench : range 0.20 to 3.60 m.daN
(2.00 to 26.00 lbf.ft)
B. Consumable Materials
-------------------------------------------------------------------------------REFERENCE DESIGNATION -------------------------------------------------------------------------------
Material No. 07-001D D 75-T-2-5721-3-1 ELECTRICAL BONDING COATING (BLUE COLOR) (Ref. 20-31-00)
Material No. 09-016B USA MIL-PRF-81733D TYPE II CORROSION INHIBITING FILLET CONSISTENCY (Ref. 20-31-00)
C. Referenced Information
-------------------------------------------------------------------------------REFERENCE DESIGNATION -------------------------------------------------------------------------------
24-41-00-861-002 Energize the Aircraft Electrical Circuits from the External Power 24-41-00-862-002 De-energize the Aircraft Electrical Circuits Supplied from the External Power 25-55-12-000-003 Removal of the Sidewall Panels in the AFT Cargo Compartment - FR59/FR65 25-55-12-400-003 Installation of the Sidewall Panels in the AFT Cargo Compartment - FR59/FR65
-------------------------------------------------------------------------------REFERENCE DESIGNATION -------------------------------------------------------------------------------
35-00-00-860-001 Special precautions when working on a Gaseous Oxygen
System 35-21-00-614-002 Filling of the Passenger Oxygen Cylinders 35-23-00-790-001 Leak Check of Components in the Intermediate Line of
the Oxygen System 52-30-00-860-001 Open the FWD or AFT Cargo-Compartment Door with the Yellow Electric Pump 52-30-00-860-002 Close the FWD or AFT Cargo-Compartment Door with the Yellow Electric Pump 35-23-55-991-001 Fig. 401
3. Job Set-up
__________
Subtask 35-23-55-860-051
A. Aircraft Maintenance Configuration
(1)
中国航空网 www.aero.cn
航空翻译 www.aviation.cn
本文链接地址:A320飞机维护手册 AMM OXYGEN 氧气(158)