35-13-15Page 406
May 01/05
R **ON A/C ALL
TASK 35-13-15-400-001
Installation of the Oxygen Pressure Regulator/Transmitter (4HT)
1. Reason for the Job
__________________
Self Explanatory
2. Job Set-up Information
______________________
A. Fixtures, Tools, Test and Support Equipment
-------------------------------------------------------------------------------REFERENCE QTY DESIGNATION -------------------------------------------------------------------------------
No specific blanking cap
No specific sealed vinyl bag
No specific access platform 2 m (6 ft. 7 in.)
No specific Torque Wrench : range 1.00 to 10.00 m.daN
(8.00 to 75.00 lbf.ft)
B. Consumable Materials
-------------------------------------------------------------------------------REFERENCE DESIGNATION -------------------------------------------------------------------------------
Material No. 05-003B USA MIL-G-27617
OXYGEN SYSTEM LUBRICANT (Ref. 20-31-00)
Material No. 05-004 USA MIL-L-25567 TYPE I
OXYGEN LEAK DETECTOR (Ref. 20-31-00)
C. Expendable Parts
-------------------------------------------------------------------------------FIG.ITEM |DESIGNATION |IPC-CSN -------------------------------------------------------------------------------
2 bush 35-11-01 02 -020
R 2 bush 35-11-01 02A-020 4 bush 35-12-01 01 -010 7 bush 35-12-01 01 -010
EFF : ALL
35-13-15Page 407
D. Referenced Information
-------------------------------------------------------------------------------
REFERENCE DESIGNATION
-------------------------------------------------------------------------------
24-41-00-862-002 De-energize the Aircraft Electrical Circuits Supplied from the External Power
R **ON A/C 001-049, 101-149, 151-199, 201-299, 301-399, 401-499,
35-13-15-991-001 Fig. 401
**ON A/C 051-099,
35-13-15-991-001-A Fig. 401A
**ON A/C ALL
3. Job Set-up
__________
Subtask 35-13-15-860-051
A. Aircraft Maintenance Configuration
(1)
Make sure that the access platform is in position at the access door
812.
(2)
Make sure that the access door 812 is open.
(3)
Make sure that the parts retained from the removed component are clean and in the correct condition.
Subtask 35-13-15-865-051
B. Make sure that this(these) circuit breaker(s) is(are) open, safetied and tagged
-------------------------------------------------------------------------------
PANEL DESIGNATION IDENT. LOCATION
-------------------------------------------------------------------------------
49VU OXYGEN/CREW/OXY/SPLY 1HT HA01
EFF : ALL
35-13-15Page 408
4. Procedure
_________ R **ON A/C 001-049, 101-149, 151-199, 201-299, 301-399, 401-499,
(Ref. Fig. 401/TASK 35-13-15-991-001)
**ON A/C 051-099,
(Ref. Fig. 401A/TASK 35-13-15-991-001-A) R **ON A/C 001-049, 101-149, 151-199, 201-299, 301-399, 401-499,
Subtask 35-13-15-420-051
A. Installation of the Oxygen Pressure Regulator/Transmitter NOTE : Only use SPECIAL MATERIALS (Material No. 05-003B) on the thread of
____ the nut or on the flared part of the tube. Only apply a thin layer of the compound to the first three male-threads.
(1)
Remove the oxygen-cylinder stowage cap from the cylinder valve (11).
(2)
Install the transmitter (9) on the valve (11) and tighten the nut (8) to between 7.5 and 8 m.daN (55.30 and 58.99 lbf.ft)
(3)
Remove the plug assy (1) from the sealed vinyl bag.
(4)
Remove the blanking cap from the plug assy (1).
(5)
Install the new bush (2) on the plug assy (1).
(6) 中国航空网 www.aero.cn 航空翻译 www.aviation.cn 本文链接地址:A320飞机维护手册 AMM OXYGEN 氧气(48)