A. Cleaning of the mask, the harness, the mask regulator and the mask stowage box
(1)
Clean the mask and the harness with the cleaning solution and a soft brush or a spongy cloth.
(2)
Flush with clean water. Rub with a clean cloth and let the mask become dry in the air.
(3)
Clean the inner surfaces of the mask with the DISINFECTANTS (Material No. 14-002).
(4)
Clean all the parts that are not made of elastomer with the CLEANING AGENTS (Material No. 11-005).
(5)
Clean the parts that are made of elastomer with the cleaning solution.
(6)
Carefully remove the solution with a clean cloth.
EFF : ALL
35-12-41Page 702
(7)
Dry all the parts with low-pressure, compressed air that is filtered
and has no oil.
(8)
Clean the stowage box with a clean cloth.
5. Close-up
________ Subtask 35-12-41-420-055
A. Put the aircraft back to its initial configuration.
(1) Install the full-face/quick-donning oxygen mask (Ref. TASK 35-12-41-400-002).
EFF : ALL
35-12-41Page 703
CONTROL AND INDICATING - DESCRIPTION AND OPERATION
__________________________________________________
1. General
_______
The oxygen indicating system gives control and monitoring of the crew oxygen
system.
R **ON A/C 001-049, 101-149, 151-199, 201-299, 301-399, 401-499,
2. System Description
__________________
(Ref. Fig. 001)
A. Direct Reading Pressure Gage A direct reading pressure gage is installed on the oxygen cylinder to indicate the oxygen pressure. This gives an indication to the maintenance personnel when to fill the oxygen cylinder.
B. Not Applicable
**ON A/C 051-099,
2. System Description
__________________
(Ref. Fig. 001A)
A. Direct Reading Pressure Gage A direct-reading pressure gage is installed on the oxygen cylinder to indicate the oxygen pressure. This gives an indication to the maintenance personnel when to fill the oxygen cylinder.
B. Filling Indicator The filling indicator is installed near the replenishing connector in the space provided between frame 13 and frame 15. The filling indicator permits to read the pressure inside the cylinder while filling: 0 -85 psig: RED 85-2000 psig: GREEN
**ON A/C 001-049, 051-099, 101-105, 151-199, 201-299, 301-302,
C. Cockpit Indications
(Ref. Fig. 002)
(1) On the lower ECAM DU, on the DOOR/OXY page, the oxygen pressure in the cylinder is indicated as follows:
(a) 0 to 27.5 bar (0 to 400 psig) in amber.
EFF : ALL
35-13-00Page 1
(c) An amber half frame appears when the oxygen pressure is lower than 1500 psig.
R **ON A/C 106-149, 303-399, 401-499,
C. Cockpit Indications
(Ref. Fig. 002)
(1) On the lower ECAM DU, on the DOOR/OXY page, the oxygen pressure in the cylinder is indicated as follows:
(a)
Less than 27.5 bar (400 psig) in amber.
(b)
From 27.5 to less than 55.2 bar (400 to less than 800 psig) pulses in green.
(c)
Equal to or more than 55.2 bar (800 psig) in green.
(d)
An amber half frame appears when the oxygen pressure is lower than 103.42 bar (1500 psig).
**ON A/C ALL
(2) If the oxygen pressure drops below the minimum operating pressure of
3.45 plus or minus 0.35 bar (50 plus or minus 5 psig), the indication REGUL LO PR is shown amber on the DOOR/OXY page.
EFF : ALL
35-13-00Page 2
Control and Indicating-Schematic
Figure 001
R EFF : 001-049, 101-149, 151-199, 201-299, 35-13-00Page 3/4 301-399, 401-499, Aug 01/05
CES R Control and Indicating-Schematic R Figure 001A
R EFF : 051-099, 35-13-00Page 5/6 May 01/05
CES
Cockpit Indications
Figure 002
EFF : ALL 35-13-00 Page 7
May 01/05
CES
PRESSURE SWITCH - OXYGEN (4WV) - REMOVAL/INSTALLATION
_____________________________________________________
TASK 35-13-14-000-001 Removal of the Press Sw-Oxygen LO PR (4WV) WARNING : KEEP ALL HYDROCARBONS (FUELS, LUBRICANTS, ETC.) AWAY FROM ALL SOURCE
_______ OF OXYGEN. OXYGEN BECOMES EXPLOSIVE WHEN IT TOUCHES HYDROCARBONS.
WARNING : CLEAN THE TOOLS AND MAKE SURE YOUR HANDS ARE CLEAN TO PREVENT
_______ CONTAMINATION OF THE OXYGEN SYSTEM.