No specific blanking cap No specific blanking plug No specific circuit breaker(s) safety clip(s) No specific warning notice No specific access platform 2 m (6 ft. 7 in.)
 B. Referenced Information
 -------------------------------------------------------------------------------REFERENCE DESIGNATION -------------------------------------------------------------------------------
24-41-00-861-002  Energize the Aircraft Electrical Circuits from the External Power 35-13-51-991-001 Fig. 401
 EFF : ALL

35-13-51Page 401


 3. Job Set-up
__________ Subtask 35-13-51-010-050
 A. Get Access
 (1) Put the access platform in position at the access door 812.
 (2) Open the access door 812. Subtask 35-13-51-860-050
 B. Aircraft Maintenance Configuration
 (1)
 Energize the electrical circuits (Ref. TASK 24-41-00-861-002).

 (2)
 Close the valve of the oxygen cylinder/valve assembly (5750HM).

 (3)
 Put a warning notice to tell persons not to open the valve of the oxygen cylinder assembly.


 Subtask 35-13-51-870-050
 C. Bleed the oxygen system:
 (1)
 In the cockpit, on the panel 21VU, push the OXYGEN/CREW SUPPLY pushbutton switch. The OFF legend goes off.

 (2)
 On an oxygen-mask stowage box, operate the PRESS TO TEST AND RESET control slide a sufficient number of times to make the system empty.

 (3)
 On the panel 21VU, release the OXYGEN/CREW SUPPLY pushbutton switch. The OFF legend comes on.


 Subtask 35-13-51-865-050
 D. Open, safety and tag this(these) circuit breaker(s):
 -------------------------------------------------------------------------------PANEL DESIGNATION IDENT. LOCATION -------------------------------------------------------------------------------49VU OXYGEN/CREW/OXY/SPLY 1HT HA01
 EFF : ALL

35-13-51Page 402


 4. Procedure
_________
 (Ref. Fig. 401/TASK 35-13-51-991-001) Subtask 35-13-51-020-050
 A. Removal of the LP Oxygen-Supply Solenoid-Valve (3HT)
 (1)
 Disconnect the electrical connector (9) from the LP oxygen-supply solenoid-valve (6).

 (2)
 Put a blanking cap on the disconnected electrical connector (9).

 (3)
 Disconnect the pipe (8) and discard the bush (7).

 (4)
 Put a blanking plug on the pipe (8).

 (5)
 Disconnect the pipe (5) and discard the bush (4).

 (6)
 Put a blanking plug on the pipe (5).

 (7)
 Remove the screws (2), the washers (3) and the solenoid valve (6).


 EFF : ALL

35-13-51Page 403


 LP Oxygen-Supply Solenoid-Valve
 Figure 401/TASK 35-13-51-991-001
 EFF :  ALL  35-13-51 Page 404 
Feb 01/98
 CES 

 

 TASK 35-13-51-400-001
 Installation of the LP Oxygen-Supply Solenoid-Valve (3HT)
 1. Reason for the Job
__________________
 Self Explanatory
 2. Job Set-up Information
______________________
 A. Fixtures, Tools, Test and Support Equipment
 -------------------------------------------------------------------------------REFERENCE QTY DESIGNATION -------------------------------------------------------------------------------
No specific blanking plug
 No specific warning notice
 No specific access platform 2 m (6 ft. 7 in.)
 No specific Torque Wrench : range 0.20 to 3.60 m.daN

 (2.00 to 26.00 lbf.ft)
 B. Consumable Materials
 -------------------------------------------------------------------------------REFERENCE DESIGNATION -------------------------------------------------------------------------------
Material No. 05-003B USA MIL-G-27617
 OXYGEN SYSTEM LUBRICANT (Ref. 20-31-00)
 Material No. 05-004 USA MIL-L-25567 TYPE I
 OXYGEN LEAK DETECTOR (Ref. 20-31-00)

 C. Expendable Parts
 -------------------------------------------------------------------------------FIG.ITEM |DESIGNATION |IPC-CSN -------------------------------------------------------------------------------
4 bush 35-12-01 01 -010 R 7 bush 35-12-01 01 -010 R
 EFF : ALL

35-13-51Page 405


 D. Referenced Information
 -------------------------------------------------------------------------------REFERENCE DESIGNATION -------------------------------------------------------------------------------
24-41-00-861-002 Energize the Aircraft Electrical Circuits from the External Power 24-41-00-862-002 De-energize the Aircraft Electrical Circuits Supplied from the External Power 35-13-51-991-001 Fig. 401
 
中国航空网 www.aero.cn
航空翻译 www.aviation.cn
本文链接地址:A320飞机维护手册 AMM OXYGEN 氧气(54)