R  (1) Open the stowage box doors. 
R  (2) Remove the blanking cap from the electrical connector (8). 
R  (3) Connect the electrical connectors (8) and (9). 
R  (4) Remove the blanking plug from the connector (6). 
R  (5) Connect the connectors (5) and (6). 
R  (6) Hold the mask regulator (2). 
R R  (7) Put the inflation harness on the mask. Do not put the inflation harness in the face piece hole. 
R R  (8) Put the hose (4) into coils (do not turn the mask) and put it in position on the top of the mask. 
R R  (9) Put the assembly into the stowage box (7) and make sure that the hose is on the side of the stowage box (crew leg side).


35-12-41Page 413
Feb 01/02


 (10) Put the hose (4) in the middle in the correct position when the doors

 are closed.
 Make sure that the mask is fully against the stop of the stowage box.

 (11) Close the doors.
 Subtask 35-12-41-865-056

 C. Remove the safety clip(s) and the tag(s) and close this(these) circuit breaker(s):
 -------------------------------------------------------------------------------PANEL DESIGNATION IDENT. LOCATION -------------------------------------------------------------------------------49VU OXYGEN/CREW/OXY/SPLY 1HT HA01
 Subtask 35-12-41-860-057
 D. Preparation of the test
 (1) Make sure that the mask is correctly installed in the box:
 (a)
 On the OVHD panel 21VU: Push the OXYGEN/CREW SUPPLY pushbutton switch. The OFF legend goes off.

 (b)
 On the oxygen box: Push the PRESS TO TEST AND RESET control slide. Make sure that the OXY ON flag goes out of view. Release the PRESS TO TEST AND RESET control slide.


 Subtask 35-12-41-710-051
 E. Test
R (1) Do the operational test of the oxygen mask microphone (Ref. TASK 23-R 51-00-710-004).
 (2) Do the operational test of the audio management (Ref. TASK 23-51-00-710-001).
 EFF : ALL

35-12-41Page 414


 MASK - FULL FACE/QUICK DONNING, OXYGEN (10RN1,10RN2,10RN3,5757HM,5758HM,5759HM,
_______________________________________________________________________________
 5760HM,5774HM) - ADJUSTMENT/TEST
________________________________
 TASK 35-12-41-710-001
 Operational Test of the Full Face/Quick Donning Oxygen Masks

R  (5757HM,5758HM,5759HM,5760HM) WARNING : KEEP ALL HYDROCARBONS (FUELS, LUBRICANTS, ETC.) AWAY FROM ALL SOURCE
_______ OF OXYGEN. OXYGEN BECOMES EXPLOSIVE WHEN IT TOUCHES HYDROCARBONS.
 WARNING : CLEAN THE TOOLS AND MAKE SURE YOUR HANDS ARE CLEAN TO PREVENT
_______
 CONTAMINATION OF THE OXYGEN SYSTEM.

 1. Reason for the Job
__________________
 Refer to the MPD TASK: 351000-01
 Make sure that the all the crew oxygen masks operate correctly.

 2. Job Set-up Information
______________________
 A. Referenced Information
 -------------------------------------------------------------------------------REFERENCE DESIGNATION -------------------------------------------------------------------------------
24-41-00-861-002  Energize the Aircraft Electrical Circuits from the External Power 24-41-00-862-002 De-energize the Aircraft Electrical Circuits Supplied from the External Power
 3. Job Set-up
__________
 Subtask 35-12-41-860-050

 A. Aircraft Maintenance Configuration
 (1)
 Energize the aircraft electrical circuits (Ref. TASK 24-41-00-861-002)

 (2)
 On the panel 21VU :


 -push the OXYGEN/CREW SUPPLY pushbutton switch (the OFF legend goes off).
 EFF : ALL


35-12-41Page 501


 Subtask 35-12-41-865-050
 B. Make sure that this(these) circuit breaker(s) is(are) closed:
 -------------------------------------------------------------------------------
PANEL DESIGNATION IDENT. LOCATION -------------------------------------------------------------------------------
49VU OXYGEN/CREW/OXY/SPLY  1HT  HA01
 4. Procedure_________
 Subtask 35-12-41-710-050
 A. Operational test
 (1) Do the test of all the full-face/quick-donning oxygen masks.
 -------------------------------------------------------------------------------
ACTION RESULT -------------------------------------------------------------------------------
R R R  NOTE : The 4th Occupant mask is not connected to the Audio Control____ Panel (ACP). Thus, the steps related to the ACP are not applicable to the 4th Occupant mask.
R R R R  1. On the CAPT Audio Control Panel (ACP) for the CAPT oxygen mask (only), installed on the left side: or On the F/O and 3rd Occupant Audio Control Panel (ACP) for the oxygen mask(s) installed on the right side (F/O mask and 3rd Occupant mask) : - push the INT reception pushbutton switch and adjust the audio level to the minimum level that you can hear. - set the INT/RAD switch to INT.
 