 (2) Disconnect the clips (2) from the lanyards (1).
 (3) Carefully remove the oxygen supply hoses (4) from the outlet manifold (5) and remove the masks (3).
 (4) Release the clamp (6) and remove the generator (7).


35-21-42Page 403


R  Emergency Oxygen Generators - Removal/Installation Figure 401/TASK 35-21-42-991-001- 12 (SHEET 1)
 EFF :  ALL  35-21-42 Page 404 Aug 01/05
 CES 

 

R  Emergency Oxygen Generators - Removal/Installation Figure 401/TASK 35-21-42-991-001- 22 (SHEET 2)
 EFF :  ALL  35-21-42 Page 405 Aug 01/05
 CES 

 

 TASK 35-21-42-400-001
 Installation of the Emergency Oxygen Generators 
R R R R R R R  WARNING : MAKE SURE THAT YOU OBEY THE MANUFACTURER'S INSTRUCTIONS AND NATIONAL_______ HAZARDOUS MATERIAL REGULATIONS WHEN YOU MOVE OR KEEP THIS EQUIPMENT IN STORAGE: - CHEMICAL OXYGEN CYLINDERS - PROTECTIVE BREATHING EQUIPMENT - FIXED AND PORTABLE OXYGEN CYLINDERS. SPECIAL PRECAUTIONS ARE NECESSARY FOR THIS EQUIPMENT.
 1. Reason for the Job__________________
 Self Explanatory
 2. Job Set-up Information______________________
 A. Referenced Information
 -------------------------------------------------------------------------------REFERENCE DESIGNATION -------------------------------------------------------------------------------
R  24-41-00-861-002 24-41-00-862-002 35-23-00-550-001 35-23-00-710-001 35-21-42-991-001  Energize the Aircraft Electrical Circuits from the External PowerDe-energize the Aircraft Electrical Circuits Supplied from the External PowerPacking of the Oxygen Masks Operational Check of Manual Mask ReleaseFig. 401
 3. Job Set-up__________
 Subtask 35-21-42-860-050
 A. Aircraft Maintenance Configuration
 (1) Energize the aircraft electrical circuits (Ref. TASK 24-41-00-861-002).
 (2) Examine the oxygen masks and the supply hoses for serviceable condition.
 WARNING : CLEAN THE TOOLS AND MAKE SURE YOUR HANDS ARE CLEAN TO_______ PREVENT CONTAMINATION OF THE OXYGEN SYSTEM.


35-21-42Page 406
Feb 01/05

 

 Subtask 35-21-42-865-053
 B. Make sure that this(these) circuit breaker(s) is(are) open, safetied and tagged
 -------------------------------------------------------------------------------PANEL DESIGNATION IDENT. LOCATION -------------------------------------------------------------------------------
49VU OXYGEN/PASSENGER/ACTUATION 7WR HA08 49VU OXYGEN/PASSENGER/ACTUATION 6WR HA07 49VU OXYGEN/PASSENGER/ACTUATION 5WR HA06 49VU OXYGEN/PASSENGER/ACTUATION 4WR HA05
 4. Procedure
_________
 (Ref. Fig. 401/TASK 35-21-42-991-001) Subtask 35-21-42-420-051
 A. Installation of the Oxygen Generator WARNING : BEFORE INSTALLATION, MAKE SURE THAT YOU REMOVE THE SAFETY RINGS
_______ OR THE SAFETY PINS FROM THE GENERATORS. IF YOU DO NOT, THE GENERATORS WILL NOT OPERATE.
 CAUTION : DO NOT PULL THE GENERATOR-END OF THE LANYARD.
_______

 (1)
 Remove and discard the old test button label (8).

 (2)
 Fill the date (month and year) in the space of the new test button label, as necessary and apply the new test button label to the end of the test button assy.

 (3)
 Install the generator (7) in the container against the foam ring (10) and make sure that the pins engage in the clamp (6).

 (4)
 Remove the relevant safety ring or safety pin (9). NOTE : The generator/actuator pin (11) and the lanyards must point


____ away from the door hinge of the oxygen container.
 NOTE : Make sure that the generator/actuator pin (11) is installed
____
 between 0 degrees to 160 degrees.

 (5) Tighten the clamp (6).
 EFF : ALL

35-21-42Page 407


 (6) Carefully install the oxygen supply hoses (4) on the outlet manifold (5).
 NOTE : To make the installation of the supply hoses easier, put the
____ R ends of the supply hoses into clean distilled water.
 (7)
 Connect the clips (2) on to the lanyards (1).

 (8)
 Put the mask assemblies into the emergency oxygen containers (Ref. TASK 35-23-00-550-001).

 (9)
 Make sure that there is a minimum clearance of 2.0 +0 -0.5 mm (0.0787 +0.0000 -0.0196 in.) around the oxygen container door.


 (10) Make sure that the door stop is in line with the door, and the door is safe.
 Subtask 35-21-42-710-051
 B. Do the operational test of the passenger oxygen system (Ref. TASK 35-23-00-710-001).
 5. Close-up