• 热门标签

当前位置: 主页 > 航空资料 > 机务资料 >

时间:2011-03-26 09:06来源:蓝天飞行翻译 作者:admin
曝光台 注意防骗 网曝天猫店富美金盛家居专营店坑蒙拐骗欺诈消费者


 EFF : ALL
35-32-00Page 16
Aug 01/05
R
 CES  CES  **ON A/C ALL


 **ON A/C 106-149, 151-199, 201-299,
 A. Smoke Hood
 During the donning sequence, the clorate candle is automatically
 actuated. The adjustment straps are pulled to secure the oronasal mask
 cone against the face. When the neckseal is positioned, the oxygen
 generated by the chlorate candle inflates the Smoke Hood. It provides
 adequate breathing volume and accomplish some purging of the Smoke Hood
 with any excess gas generation. When the wearer breathes through the mask
 cone, the exhaled breath is directed through the KO2 canister. It removes
 water vapor and carbon dioxide and adds oxygen before the gas is returned
 to the interior of the smoke hood. The breathing cycle continues until
 the KO2 bed is removed. It results in a loss of active oxygen generation
 capability and rapid increase in internal temperature and release of
 moisture through the KO2 bed. The loss of oxygen generation capability
 results in a reduction of the interior volume of the smoke hood.
 Inhalation becomes difficult and the smoke hood should be removed. 
R  **ON A/C 401-499, 
R  A. Full-Face Smoke Mask 
R  The smoke mask is connected to the oxygen cylinder and the ON/OFF valve 
R  is turned on. The oxygen flows through a flexible supply hose to the 
R  demand regulator. 
R  When the person breathes in, a diaphragm opens a demand valve in the 
R  demand regulator and the oxygen flows into the smoke mask. When the 
R  person breathes out, the diaphragm closes the demand valve (and stops the 
R  flow of oxygen) and opens a vent in the demand regulator. The exhaled air 
R  goes through a vent to atmosphere. 
R  When the smoke mask is put on, any unwanted gases in the smoke mask are 
R  removed with the adjustable purge button. The purge button is turned to 
R  the fully open position, pushed in and held. This operates the diaphragm 
R  and opens the demand valve. Oxygen flows into the smoke mask and forces 
R  the unwanted gas out of the face piece. You must release the purge button 
R  to stop the flow of oxygen. 
R  To get a constant flow of oxygen you must turn the purge button to the 
R  fully closed position. This operates the demand valve and provides a 
R  constant oxygen flow. You must turn the purge button to the fully open 
R  position to stop the flow of oxygen.

 

 B. Continuous-Flow Oxygen Mask
R **ON A/C 001-049, 051-099, 101-149, 151-199, 201-299, 301-399,
 (Ref. Fig. 004)
R **ON A/C ALL
 The oxygen mask is connected to the oxygen cylinder and the ON/OFF valve turned on. The oxygen flows through the supply hose into the reservoir bag. The flow indicator in the reservoir bag inflates and shows a green color. When the person breathes in, the oxygen flows from the reservoir bag through the inhalation valve into the face piece. When the oxygen in the reservoir bag is used, the ambient air valve opens and lets ambient air into the face piece. When the person breathes out, the inhalation and the ambient air valves close and the exhaled air goes through the exhalation valve. Oxygen flows into the reservoir bag for the next breathing cycle when the person is breathing out.
 EFF : ALL
35-32-00Page 18


 CABIN ATTENDANTS PORTABLE DEVICES - ADJUSTMENT/TEST
___________________________________________________
 TASK 35-32-00-710-001
 Operational Test of the Portable Oxygen Equipment
 WARNING : KEEP ALL HYDROCARBONS (FUELS, LUBRICANTS, ETC.) AWAY FROM ALL SOURCE
_______ OF OXYGEN. OXYGEN BECOMES EXPLOSIVE WHEN IT TOUCHES HYDROCARBONS.
 WARNING : CLEAN THE TOOLS AND MAKE SURE YOUR HANDS ARE CLEAN TO PREVENT
_______
 CONTAMINATION OF THE OXYGEN SYSTEM.

 WARNING : MAKE SURE THAT YOU OBEY THE MANUFACTURER'S INSTRUCTIONS AND NATIONAL
_______ HAZARDOUS MATERIAL REGULATIONS WHEN YOU MOVE OR KEEP THIS EQUIPMENT IN STORAGE:
 -CHEMICAL OXYGEN CYLINDERS
 -PROTECTIVE BREATHING EQUIPMENT
 -FIXED AND PORTABLE OXYGEN CYLINDERS. SPECIAL PRECAUTIONS ARE NECESSARY FOR THIS EQUIPMENT.
 1.
 Reason for the Job

__________________
 Self Explanatory


 2.
 Job Set-up Information


______________________
 A. Referenced Information
 -------------------------------------------------------------------------------
 
中国航空网 www.aero.cn
航空翻译 www.aviation.cn
本文链接地址:A320飞机维护手册 AMM OXYGEN 氧气(171)