(2)
Close the access door 831.
(3)
Remove the access platform(s).
R EFF : 063-099, 152-152, 204-205, 35-13-15Page 605
Inspection Report Figure 602/TASK 35-13-15-991-004
R EFF : 063-099, 152-152, 204-205, 35-13-15 Page 606 May 01/05
CES
INDICATOR - OXYGEN FILLING (5HT) - REMOVAL/INSTALLATION
_______________________________________________________
TASK 35-13-21-000-001 Removal of the Oxygen Filling Indicator (5HT) WARNING : KEEP ALL HYDROCARBONS (FUELS, LUBRICANTS, ETC.) AWAY FROM ALL SOURCE
_______ OF OXYGEN. OXYGEN BECOMES EXPLOSIVE WHEN IT TOUCHES HYDROCARBONS.
1.
Reason for the Job
__________________
Self Explanatory
2.
Job Set-up Information
______________________
A. Fixtures, Tools, Test and Support Equipment
-------------------------------------------------------------------------------REFERENCE QTY DESIGNATION -------------------------------------------------------------------------------
No specific blanking cap
No specific circuit breaker(s) safety clip(s)
No specific access platform 2 m (6 ft. 7 in.)
B. Referenced Information
-------------------------------------------------------------------------------REFERENCE DESIGNATION -------------------------------------------------------------------------------
24-42-00-861-001 Energize the Ground Service Network from the External Power 35-13-21-991-001 Fig. 401
3. Job Set-up
__________ Subtask 35-13-21-010-050
A. Get Access
(1)
Put the access platform in position below the access door 812.
(2)
Open the access door 812.
Subtask 35-13-21-860-050
B. Aircraft Maintenance Configuration
(1) Energize the ground service network (Ref. TASK 24-42-00-861-001). Subtask 35-13-21-865-050
C. Open, safety and tag this(these) circuit breaker(s):
-------------------------------------------------------------------------------PANEL DESIGNATION IDENT. LOCATION -------------------------------------------------------------------------------49VU OXYGEN/CREW/OXY/SPLY 1HT HA01
4. Procedure
_________
(Ref. Fig. 401/TASK 35-13-21-991-001) Subtask 35-13-21-020-050
A. Removal of the Oxygen Filling Indicator.
(1)
Disconnect the electrical connector (4) from the indicator (1).
(2)
Put a blanking cap on the disconnected electrical connector (4).
(3)
Loosen the adjusting screw (2) of the clamp (3).
(4)
Remove the indicator (1) from the clamp (3).
Oxygen Filling Indicator
Figure 401/TASK 35-13-21-991-001
EFF : 051-099, 35-13-21 Page 403
May 01/05
CES
TASK 35-13-21-400-001
Installation of the Oxygen Filling Indicator (5HT)
1.
Reason for the Job
__________________
Self Explanatory
2.
Job Set-up Information
______________________
A. Fixtures, Tools, Test and Support Equipment
-------------------------------------------------------------------------------REFERENCE QTY DESIGNATION -------------------------------------------------------------------------------
No specific blanking cap
No specific access platform 2 m (6 ft. 7 in.)
B. Referenced Information
-------------------------------------------------------------------------------REFERENCE DESIGNATION -------------------------------------------------------------------------------
24-42-00-861-001 Energize the Ground Service Network from the External Power 24-42-00-862-001 De-energize the Ground Service Network Supplied from the External Power 35-13-21-991-001 Fig. 401
3. Job Set-up
__________ Subtask 35-13-21-860-051
A. Aircraft Maintenance Configuration
(1)
Make sure that the access platform is in position at the access door
812.
(2)
Make sure that the access door 812 is open.
(3)
Make sure that the ground service network is energized (Ref. TASK 24-42-00-861-001).
中国航空网 www.aero.cn
航空翻译 www.aviation.cn
本文链接地址:A320飞机维护手册 AMM OXYGEN 氧气(51)