(7)
Make sure that the applicable emergency exit hatches are removed (Ref. TASK 52-21-11-000-001).
(8)
Make sure that the access panels are removed: NOTE : Access panel numbers for the RH emergency escape-slide
____ release-mechanism assembly are given in the brackets.
(a)
Make sure that the cove light panels 241DW (242DW), 241HW (242HW) and 241MW (242MW) are removed (Ref. TASK 25-23-48-000-001).
(b)
Make sure that the emergency-exit door-frame linings 241CW (242CW) and 214LW (242LW) are removed (Ref. TASK 25-23-47-000-002).
(9) Make sure that the insulation blankets, in the area that you are working, are removed (Ref. TASK 25-80-00-000-001).
R EFF : 001-049, 051-099, 101-149, 151-199, 25-62-43Page 459 201-299, 401-499, Aug 01/05
CES
(10)
Make sure that the proximity switches 5WN1 and 5WN2 are removed (Ref. TASK 52-73-11-000-003).
(11)
Make sure that the proximity switches 6WN1 and 6WN2 are removed (Ref. TASK 52-73-11-000-004).
R **ON A/C 151-199, 401-499,
Subtask 25-62-43-860-055-A
A. Aircraft Maintenance Configuration
(1)
Make sure that the ground service network is energized (Ref. TASK 24-42-00-861-001).
(2)
Make sure that the AFT cargo-compartment door is open (Ref. TASK 52-30-00-860-001).
(3)
Make sure that the access platform is in position at the AFT cargo-compartment door.
(4)
Make sure that the warning notice, to tell persons not to close the door, is in position on the AFT cargo-compartment door.
(5)
Make sure that the special precautions for the offwing escape-slide system(s) have been obeyed (Ref. TASK 25-62-00-481-001).
(6)
Make sure that the passenger seats in the area of the applicable emergency exit hatches are removed (Ref. TASK 25-21-41-000-001).
(7)
Make sure that the applicable emergency exit hatches are removed (Ref. TASK 52-21-11-000-001).
(8)
Make sure that the access panels are removed NOTE : Access panel numbers for the RH emergency escape-slide
____ release-mechanism assembly are given in the brackets.
(a)
Make sure that the cove light panel 241MW (242MW) is removed (Ref. TASK 25-23-48-000-001).
(b)
Make sure that the emergency-exit door-frame lining 241FW (242FW) is removed (Ref. TASK 25-23-47-000-002).
(9) Make sure that the insulation blankets, in the area that you are working, are removed (Ref. TASK 25-80-00-000-001).
R EFF : 001-049, 051-099, 101-149, 151-199, 25-62-43Page 460 201-299, 401-499, Aug 01/05
CES
(10) Make sure that the proximity switches 6WN1 and 6WN2 are removed (Ref. TASK 52-73-11-000-004).
R **ON A/C 001-049, 051-099, 101-149, 151-199, 201-299, 401-499,
4. Procedure
_________
Subtask 25-62-43-210-054
A. Preparation for Installation
(1) Clean the component interface and the adjacent area:
WARNING : MAKE SURE THAT THERE IS A GOOD FLOW OF AIR THROUGH THE WORK
_______ AREA WHEN YOU USE SPECIAL MATERIALS. IF YOU GET ONE OF THESE MATERIALS ON YOUR SKIN, IN YOUR MOUTH OR IN YOUR EYES : -FLUSH IT AWAY WITH A FLOW OF CLEAN WATER FOR BETWEEN 10 AND 15 MINUTES. -GET IMMEDIATE MEDICAL AID IF IRRITATION OCCURS. DO NOT BREATHE THE FUMES FROM THE MATERIAL. DO NOT SMOKE WHEN YOU USE THE MATERIAL. DO NOT USE THE MATERIAL NEAR A FLAME, SPARKS OR SOURCES OF HEAT. THESE MATERIALS ARE DANGEROUS : THEY ARE POISONOUS, FLAMMABLE AND SKIN IRRITANTS.
WARNING : OBEY THE MANUFACTURER'S INSTRUCTIONS WHEN YOU USE
_______ THIS/THESE MATERIAL/S. USE PROTECTIVE CLOTHING, RUBBER GLOVES, GOGGLES AND A MASK.
(a) Clean the component interface and the adjacent area with CLEANING AGENTS (Material No. 11-003) a clean cloth and a nonmetallic scraper.
(2)
Do an inspection of the component interface and/or the adjacent area.
(3)
Make sure that the parts retained from the removed component are clean and in the correct condition.
R EFF : 001-049, 051-099, 101-149, 151-199, 25-62-43Page 461 201-299, 401-499, Aug 01/05
CES R **ON A/C 001-049, 051-099, 101-149, 201-299,
Subtask 25-62-43-420-054
B. Installation of the Emergency Escape-Slide Release-Mechanism
WARNING : MAKE SURE THAT THERE IS A GOOD FLOW OF AIR THROUGH THE WORK
_______ AREA WHEN YOU USE SPECIAL MATERIALS. IF YOU GET ONE OF THESE MATERIALS ON YOUR SKIN, IN YOUR MOUTH OR IN YOUR EYES : -FLUSH IT AWAY WITH A FLOW OF CLEAN WATER FOR BETWEEN 10 AND 15 MINUTES. -GET IMMEDIATE MEDICAL AID IF IRRITATION OCCURS. DO NOT BREATHE THE FUMES FROM THE MATERIAL. DO NOT SMOKE WHEN YOU USE THE MATERIAL. DO NOT USE THE MATERIAL NEAR A FLAME, SPARKS OR SOURCES OF HEAT. THESE MATERIALS ARE DANGEROUS : THEY ARE POISONOUS, FLAMMABLE AND SKIN IRRITANTS.
中国航空网 www.aero.cn
航空翻译 www.aviation.cn
本文链接地址:A320飞机维护手册 AMM EQUIPMENT/FURNISHINGS 设备4(98)