Cabin Escape Facilities - Location Figure 001
R EFF : 001-002, 25-62-00 Page 2 Feb 01/99
CES
Cabin Escape Facilities - Location Figure 001A
R EFF : 003-049, 051-099, 101-149, 201-299, 25-62-00 Page 3 May 01/05
CES
Cabin Escape Facilities - Location Figure 001B
R EFF : 151-199, 401-499, 25-62-00 Page 4 Aug 01/05
CES
**ON A/C 301-399,
(Ref. Fig. 001C)
-------------------------------------------------------------------------------FIN | FUNCTIONAL DESIGNATION | PANEL|ZONE|ACCESS | ATA | | | | DOOR | REF. -------------------------------------------------------------------------------
7500MM ESCAPE SLIDE FWD L
7501MM ESCAPE SLIDE FWD R
7502MM ESCAPE SLIDE AFT L
7503MM ESCAPE SLIDE AFT R
7770MM ESCAPE SLIDE FOR DOOR 2LH
7771MM ESCAPE SLIDE FOR DOOR 2RH
7772MM ESCAPE SLIDE FOR DOOR 3LH
7773MM ESCAPE SLIDE FOR DOOR 3RH
7774MM PRESSURE BOTTLE DOOR 2LH
7775MM PRESSURE BOTTLE DOOR 2RH
7776MM PRESSURE BOTTLE DOOR 3LH
7777MM PRESSURE BOTTLE DOOR 3RH
**ON A/C ALL
3. System Description
__________________
A. Door Escape Facilities **ON A/C 001-002,
831 831 25-62-44841 841 25-62-44832 832 25-62-44842 842 25-62-44100 131BL 25-62-47100 132BR 25-62-47100 151BL 25-62-47100 152BR 25-62-47200 25-62-49200 25-62-49200 25-62-49200 25-62-49
Single lane escape slides are installed at all cabin doors. R **ON A/C 003-049, 051-099, 101-149, 151-199, 201-299, 401-499,
Dual lane escape slide rafts are installed at all cabin doors.
**ON A/C 301-399,
Single lane escape slides are installed at FWD/AFT emergency doors, and dual lane escape slide rafts are installed at FWD/AFT passenger/crew doors.
EFF : ALL
25-62-00Page 5
R R Cabin Escape Facilities - Location Figure 001C
R EFF : 301-399, 25-62-00 Page 6 May 01/04
CES
**ON A/C ALL
Inflation is automatic if the door is opened with the Emergency Control
Handle (ECH) in the ARMED mode.
Manual inflation is possible after the door is opened.
R **ON A/C 003-049, 051-099, 101-149, 151-199, 201-299, 301-399, 401-499,
The slide raft has a special move function that permits quick release from a damaged door, for subsequent inflation at a different door.
R **ON A/C 001-049, 051-099, 101-149, 151-199, 201-299, 401-499,
B. Offwing Escape Facilities Dual lane offwing escape slides are installed above the wings in the left and right wing-to-fuselage fairings. Inflation is automatic if the emergency exit hatch is opened in the ARMED mode. A mannual inflation handle is installed at each emergency exit. You get access to the handle after the emergency exit hatch is removed.
**ON A/C ALL
C. Warning Systems Escape facility warning systems (Ref. 52-70-00) are installed at all cabin exits. A warning light operates immediatly an exit is opened in the ARMED mode. An audible warning sound operates in the cockpit.
D. Directional Guidance Lights Directional guidance lights are installed on all escape facilities. They are attached to the longitudinal supports and across the bottom of each inflatable assembly.
E. Inflation Reservoir - Low Pressure Indication (Optional)
Pressure sensors are installed on all inflation reservoirs, and are connected to the Cabin Intercommunication Data System (CIDS). Monitoring of the pressure is an optional function (Ref. 23-73-00).
EFF : ALL
25-62-00Page 7
4. Interface
_________
The cabin escape facilities have interfaces with:
-
The CIDS (optional) (Ref. 23-73-00).
-
The cabin emergency lighting system (Ref. 33-51-00).
-
The door warning system (Ref. 52-70-00).
5. Component Description
_____________________ R **ON A/C 001-002, 151-199, 301-399, 401-499,
(Ref. Fig. 002)
**ON A/C 003-049, 051-099, 101-149, 201-299,
(Ref. Fig. 002A) R **ON A/C 001-049, 051-099, 101-149, 151-199, 201-299, 401-499,
(Ref. Fig. 003)
**ON A/C 301-399,
(Ref. Fig. 003A) R **ON A/C 001-002, 151-199, 401-499,
(Ref. Fig. 004)
**ON A/C 003-049, 051-099, 101-149, 201-299,
(Ref. Fig. 004A)
**ON A/C 301-399,