• 热门标签

当前位置: 主页 > 航空资料 > 机务资料 >

时间:2011-03-21 08:32来源:蓝天飞行翻译 作者:admin
曝光台 注意防骗 网曝天猫店富美金盛家居专营店坑蒙拐骗欺诈消费者


 1_ Loosen the nuts (40) and (41) to adjust the support bracket
 (8).
 2_ Move the support bracket (8) in a FWD or an AFT direction,
 until the tension is released.
 3_ Tighten the nuts (40) and (41).

_ the nut (33).
R  EFF : 001-049, 051-099, 101-149, 151-199, 25-62-46Page 417 201-299, 401-499, Aug 01/05
 CES


 NOTE : When you loosen the nut (33) the torsion is
____ automatically released. The nut (33) at the pulley assembly (7) is installed with loctite.
 2  Torque the nut (33) to between 0.7 and 0.8 m.daN (61.94 and
_
 70.79 lbf.in). 3 Safety the nut (33) with lockwire MISCELLANEOUS (Material No.
_
 19-010) (34).

 (16) Remove the lock pin (12) from the regulator valve assembly (6).
 (17) Put the lock pin (12) in the pocket (3). Subtask 25-62-46-865-051
 C. Remove the safety clip(s) and the tag(s) and close this(these) circuit breaker(s): 153RH, 162RH
 **ON A/C 001-049, 051-099, 101-105, 151-199, 201-299,
 Subtask 25-62-46-710-052
 D. Operational Test of the Inflation Reservoir (Slide-Bottle) monitoring, through the Cabin Intercommunication Data System (CIDS) (Ref. Fig. 401/TASK 25-62-46-991-001, 402/TASK 25-62-46-991-003)
 NOTE : This test is applicable only if the Cabin Assignment Module (CAM)
____
 is programmed to monitor the slide-bottles.

 (1) Energize the CIDS (Ref. TASK 23-73-00-861-001).
 NOTE : Two persons are necessary to do the test.

____
 -------------------------------------------------------------------------------ACTION RESULT -------------------------------------------------------------------------------
1. At the FWD ATTND station:
 -Open the access door to the
 programming and test panel
 (PTP), 110RH.

 2. At the PTP, 110RH:  On the PTP display screen:
R  EFF : 001-049, 051-099, 101-149, 151-199, 25-62-46Page 418 201-299, 401-499, Aug 01/05
 CES


 Pressure Indication Test through CIDS Figure 402/TASK 25-62-46-991-003 
R  EFF : 001-049, 051-099, 101-105, 151-199, 201-299,  25-62-46 Page 419 May 01/05
 CES 

 

 -------------------------------------------------------------------------------
ACTION RESULT -------------------------------------------------------------------------------
NOTE : You can ignore other
____ maintenance messages, if they are shown.
 -
Push the DSPL ON pushbutton switch.

 -
Push the SYSTEM STATUS line selection-key.


3. At the inflation reservoir (5):
 -Disconnect the connector (21): FOR 7506MM 7555VC-A. FOR 7507MM 7556VC-A.
 4. At the PTP, 110RH:
 -Push the line selection-key next to the message SLIDES PRESS LOW.
 5. At the inflation reservoir (5):
 -Connect the connector (21): FOR 7506MM 7555VC-A. FOR 7507MM 7556VC-A.
 6. At the PTP, 110RH:
-
The main menu page shows.

-
The SYSTEM STATUS page shows themessage SLIDES PRESS OK.


 NOTE : If the message SLIDES PRESS OK
____ does not show, push the CONT line selection-key until the message shows.
-After approximately 3 minutes theSYSTEM STATUS page shows the messageSLIDES PRESS LOW.
-
The message CHECK SLIDE PRESS showson the first line.

 -
The applicable emergency exit location shows on the next line: FOR 7506MM EMER L. FOR 7507MM EMER R.


-After approximately 3 minutes theSYSTEM STATUS page shows the messageSLIDES PRESS OK.
R  EFF : 001-049, 051-099, 101-105, 151-199, 25-62-46Page 420 201-299, May 01/05
 CES


 -------------------------------------------------------------------------------
ACTION RESULT -------------------------------------------------------------------------------- Push the DSPL ON pushbutton - The main menu page shows. switch. NOTE : The display screen switches off____ automatically after 10 minutes.
 - Close the access door. 
R  **ON A/C 106-149, 301-399, 401-499,
 Subtask 25-62-46-710-052-A
 D. Operational Test of the Inflation Reservoir (Slide-Bottle) monitoring, through the Cabin Intercommunication Data System (CIDS) 
R  **ON A/C 106-149, 401-499,
 (Ref. Fig. 401/TASK 25-62-46-991-001) 
R  **ON A/C 106-149, 301-399, 401-499,
 (Ref. Fig. 402A/TASK 25-62-46-991-003-A)
 NOTE : This test is applicable only if the Cabin Assignment Module (CAM)____ is programmed to monitor the slide-bottles.
 (1) Energize the CIDS (Ref. TASK 23-73-00-861-001).
 NOTE : Two persons are necessary to do the test.____
 
中国航空网 www.aero.cn
航空翻译 www.aviation.cn
本文链接地址:A320飞机维护手册 AMM EQUIPMENT/FURNISHINGS 设备4(130)