On the ELT 110MX:
-The RED indicator flashes one time, and the buzzer operates for 5 seconds.
-After 3 seconds the RED indicator
(12) comes on for approximately 3
seconds.
On the panel 108VU:
-The ELT indicator 113MX comes on for 5 seconds.
BITE Test - Component Location Figure 501/TASK 25-65-00-991-006- 12 (SHEET 1)
R EFF : 151-199, 211-228, 301-302, 25-65-00 Page 504 Feb 01/05
CES
BITE Test - Component Location Figure 501/TASK 25-65-00-991-006- 22 (SHEET 2)
R EFF : 151-199, 211-228, 301-302, 25-65-00 Page 505 Feb 01/05
CES
-------------------------------------------------------------------------------ACTION RESULT -------------------------------------------------------------------------------
2. On the ELT 110MX:
-
Set the ON/OFF/ARM switch (11) to the OFF position.
-
Set the ON/OFF/ARM switch (11) to the ARM position.
NOTE : A self-test mode is set
____ automatically for 5 seconds.
5. Close-up
________ Subtask 25-65-00-410-050
A. Close Access In the nose-landing-gear well:
-The mechanic call-horn 15WC operates for 5 seconds.
On the ELT 110MX:
-The RED indicator flashes one time, and the buzzer operates for 5seconds.
-After 3 seconds the RED indicator
(12) comes on for approximately 3
seconds.
On the RCP 111MX:
-The ON/TEST indicator flashes one time.
-After 3 seconds the ON/TEST indicator
(18) comes on for approximately 3
seconds.
On the panel 108VU:
-
The ELT indicator 113MX comes on for 5 seconds.
In the nose-landing-gear well:
-
The mechanic call-horn 15WC operates for 5 seconds.
(1)
Make sure that the work area is clean and clear of tool(s) and other items.
(2)
Install the ceiling panel 261BC (Ref. TASK 25-23-42-400-002).
(3)
Remove the ground support and maintenance equipment, the special and
standard tools and all other items. Subtask 25-65-00-862-051
B. De-energize the ground service network (Ref. TASK 24-42-00-862-001).
TASK 25-65-00-710-001
Operational Check of Emergency Locator Transmitter (ELT) System by Manual Activation
1.
Reason for the Job
__________________
Refer to the MPD TASK: 256535-01
2.
Job Set-up Information
______________________
A. Referenced Information
-------------------------------------------------------------------------------REFERENCE DESIGNATION -------------------------------------------------------------------------------
24-42-00-861-001 Energize the Ground Service Network from the External Power 24-42-00-862-001 De-energize the Ground Service Network Supplied from the External Power 25-65-00-991-009 Fig. 502
3. Job Set-up
__________ Subtask 25-65-00-861-054
A. Energize the ground service network
(Ref. TASK 24-42-00-861-001).
4. Procedure
_________ Subtask 25-65-00-710-050
A. Operational Test
(Ref. Fig. 502/TASK 25-65-00-991-009)
(1) In the cockpit prevent damage to the ELT electronics: CAUTION : DO NOT DO AN ANNUNCIATOR LIGHT TEST DURING THE TEST OF THE
_______ EMERGENCY LOCATOR TRANSMITTER (ELT) SYSTEM. IF YOU DO, YOU CAN CAUSE DAMAGE TO AN INTERNAL RELAY OF THE ELT.
Operational Test - Component Location Figure 502/TASK 25-65-00-991-009
R EFF : 151-199, 211-228, 301-302, 25-65-00 Page 509 Feb 01/05
CES
(a) Make sure that on the panel 25VU the ANN LT switch (1) is not set to the TEST position during the operational test.
-------------------------------------------------------------------------------ACTION RESULT -------------------------------------------------------------------------------
1. On the remote-control panel (RCP) 111MX:
-Set the ON-ARMED-TEST/RESET switch (4) to the TEST/RESET position.
NOTE : The ON-ARMED-TEST/RESET
____ switch (4) goes back automatically to the ARMED position. A self-test mode is set automatically for 5 seconds.
5. Close-up________
Subtask 25-65-00-862-054On the RCP 111MX:
-The ON/TEST indicator flashes onetime.
-After 3 seconds the ON/TEST indicator
(3) comes on for approximately 3
seconds.
NOTE : You can ignore the indications 中国航空网 www.aero.cn 航空翻译 www.aviation.cn 本文链接地址:A320飞机维护手册 AMM EQUIPMENT/FURNISHINGS 设备4(155)