 (2)
 If the automatic inflation system does not operate the reservoir valve (of the valve/regulator assembly) can be opened with the manual inflation handle. The manual inflation handle is red in color and can be seen when the emergency exit hatch is removed.

 (3)
 The directional guidance lights come on automatically during the inflation procedure. Electrical power for the lights is supplied from the cabin emergency-lighting system (Ref 33-51-00).


R  EFF : 001-049, 051-099, 101-149, 151-199, 25-62-00Page 32 201-299, 401-499, Aug 01/05
 CES


 ESCAPE FACILITIES - CABIN - MAINTENANCE PRACTICES
_________________________________________________ TASK 25-62-00-481-001 Special Precautions before Work on the Offwing Escape-Slide Systems
 1. Reason for the Job
__________________
 Installation of the lock pin in the inflation reservoir of the offwing
 escape-slide.

 2. Job Set-up Information
______________________
 A. Fixtures, Tools, Test and Support Equipment
 -------------------------------------------------------------------------------REFERENCE QTY DESIGNATION -------------------------------------------------------------------------------
No specific  access platform 2.0 m (6 ft. 7 in.)
 B. Referenced Information
 -------------------------------------------------------------------------------REFERENCE DESIGNATION -------------------------------------------------------------------------------
24-42-00-861-001  Energize the Ground Service Network from the External Power
 25-62-00-820-001  Adjustment Procedure to Install the Lock pin in the Regulator Valve Assembly of the Inflation Reservoir -Offwing Escape-Slide
 52-30-00-860-001  Open the FWD or AFT Cargo-Compartment Door with the Yellow Electric Pump 25-62-00-991-003 Fig. 201
 3. Job Set-up
__________ Subtask 25-62-00-861-053
 A. Energize the ground service network
 (Ref. TASK 24-42-00-861-001).

R  EFF : 001-049, 051-099, 101-149, 151-199, 25-62-00Page 201 201-299, 401-499, Aug 01/05
 CES  Subtask 25-62-00-010-063


 B. Access to the Inflation Reservoir (2)
 (Ref. Fig. 201/TASK 25-62-00-991-003)

 (1)
 Open the AFT cargo-compartment door (Ref. TASK 52-30-00-860-001).

 (2)
 Put an access platform in position adjacent to the AFT cargo-compartment exit.


 (3)
 Set the AFT CARGO COMPT light switch 8LU to the ON position. R (4) FOR 7506MM

 (a)
 Remove the access panel 151KW. R (5) FOR 7507MM


 (a) Remove the access panel 152KW.
 4. Procedure
_________
 Subtask 25-62-00-481-050

 A. Installation of the Lock Pin
 (Ref. Fig. 201/TASK 25-62-00-991-003)

 (1) Safety the inflation reservoir (2): WARNING : MAKE SURE THAT THE SAFETY/LOCK PIN IS CORRECTLY INSTALLED
_______ IN THE REGULATOR VALVE ASSEMBLY OF THE INFLATION RESERVOIR. THIS PREVENTS ACCIDENTAL:
 -DISCHARGE OF THE INFLATION RESERVOIR
 -DEPLOYMENT OF THE ESCAPE-SLIDE WHICH CAN CAUSE INJURY AND/OR DAMAGE.
 (a)
 Remove the lock pin (3) from the pocket (1).

 (b)
 Install the lock pin (3) in the regulator valve assembly (4).

 (c)
 If you cannot install the lock pin (3) in the regulator valve assembly (4) refer to (Ref. TASK 25-62-00-820-001).


R  EFF : 001-049, 051-099, 101-149, 151-199, 25-62-00Page 202 201-299, 401-499, Aug 01/05
 CES


 Inflation Reservoir - Install/Remove Lockpin Assembly Figure 201/TASK 25-62-00-991-003 
R  EFF : 001-049, 051-099, 101-149, 151-199, 201-299, 401-499,  25-62-00 Page 203 Aug 01/05
 CES 

 

 TASK 25-62-00-081-001
 Special Precautions after Work on the Offwing Escape-Slide Systems
 1. Reason for the Job
__________________
 Removal of the lockpin assembly from the inflation reservoir of the offwing escape-slide
 2. Job Set-up Information
______________________
 A. Fixtures, Tools, Test and Support Equipment
 -------------------------------------------------------------------------------REFERENCE QTY DESIGNATION -------------------------------------------------------------------------------
No specific  access platform 2.0 m (6 ft. 7 in.)
 B. Referenced Information
 -------------------------------------------------------------------------------REFERENCE DESIGNATION -------------------------------------------------------------------------------
24-42-00-861-001 Energize the Ground Service Network from the External Power 24-42-00-862-001 De-energize the Ground Service Network Supplied from the External Power 52-30-00-860-001 Open the FWD or AFT Cargo-Compartment Door with the Yellow Electric Pump 52-30-00-860-002 Close the FWD or AFT Cargo-Compartment Door with the Yellow Electric Pump 25-62-00-991-003 Fig. 201
 