the flame-retardant material does not cause a blockage of the latches of the latch assemblies (see DETAIL "D-D").
(e)
Make sure that the position of the decompression panel (1) in the ceiling panel (3) is symmetrical.
(f)
Make sure that all latches (2) of the latch-assemblies are locked.
R **ON A/C 106-149, 229-299, 301-399, 401-499,
R Subtask 25-68-41-920-051-C
R B. Replacement of the Decompression Panels in the Cargo-Compartment
R Ceiling-Panels
R **ON A/C 106-149, 229-299,
R (Ref. Fig. 402/TASK 25-68-41-991-002)
R **ON A/C 106-149, 229-299, 301-399, 401-499,
R (Ref. Fig. 403A/TASK 25-68-41-991-006-C)
R **ON A/C 301-399,
R (Ref. Fig. 404/TASK 25-68-41-991-003)
R **ON A/C 401-499,
R (Ref. Fig. 405/TASK 25-68-41-991-004)
R **ON A/C 106-149, 229-299, 301-399, 401-499,
R (1) Remove the decompression panel:
R (a) Remove the nuts (7) and the washers (6).
R (b) Remove the sheet-assemblies (4) and the decompression-fasteners
R (5).
R (c) Carefully remove the decompression-frame (3) and the
R decompression-panel (2) from the ceiling-panel (1).
R (2) Install the decompression-panel:
R CAUTION : DO NOT USE TOO MUCH FORCE WHEN YOU REMOVE THE COVER AS THIS_______
R CAN CAUSE DAMAGE TO THE RETAINER.
CES
R (a) Make sure that the parts retained from the removed component are
R clean and in the correct condition.
R (b) Clean the component interface and/or the adjacent area.
R (c) Do an inspection of the component interface and/or the adjacent
R area.
R (d) If necessary, install new flame-retardant material
R (referred to as the strips):
R 1_ Remove the remaining strips (8) and the foam-tape (9) from the
R ceiling-panel (1) and from the decompression-panel (2).
R 2_ Clean the area where you removed the strips and the foam-tape:
R WARNING : USE SOLVENTS/CLEANING AGENTS, SEALANTS AND OTHER_______
R SPECIAL MATERIALS ONLY WITH A GOOD SUPPLY OF AIR.
R OBEY THE MANUFACTURERS INSTRUCTIONS.
R PUT ON PROTECTIVE CLOTHING.
R DO NOT GET THEM IN YOUR MOUTH.
R DO NOT SMOKE.
R DO NOT BREATHE THE GAS.
R THESE MATERIALS ARE POISONOUS, FLAMMABLE AND SKIN
R IRRITANT.
R GET MEDICAL HELP IF YOUR SKIN OR EYES BECOME
R IRRITATED.
R a_ Clean the area where you removed the strips and the
R foam-tape with CLEANING AGENTS (Material No. 11-003) and a
R cotton cloth MISCELLANEOUS (Material No. 19-003).
R 3_ Cut the new foam-tape SPECIAL MATERIALS (Material No. 05-066)
R (9) to the necessary length.
R 4_ Remove the protective foil from the foam-tape (9).
R 5_ Carefully install the foam-tape (9) in the applicable areas of
R the ceiling-panel (1) and the decompression-panel (2).
R NOTE : The joints of the foam-tape should not be in the____
R corners of the installation area, when you install the
R new foam-tape (9).
R 6_ Cut the new Active Fire-Blocking Strip ABS5027C 15-06 (8) to
R the necessary length.
R Decompression Panels in the Cargo-Compartment Ceiling-Panels R Figure 403A/TASK 25-68-41-991-006-C12 (SHEET 1)
R EFF : 106-149, 229-299, 301-399, 401-499, 25-68-41Page 414 Aug 01/05
CES R Decompression Panels in the Cargo-Compartment Ceiling-Panels R Figure 403A/TASK 25-68-41-991-006-C22 (SHEET 2)
R EFF : 106-149, 229-299, 301-399, 401-499, 25-68-41Page 415 Aug 01/05
CES
Decompression Panels in the Cargo-Compartment Ceiling-Panels R Figure 403B/TASK 25-68-41-991-006-B12 (SHEET 1)
R EFF : 155-199, 208-228, 25-68-41Page 416 Aug 01/05
CES
Decompression Panels in the Cargo-Compartment Ceiling-Panels R Figure 403B/TASK 25-68-41-991-006-B22 (SHEET 2)
R EFF : 155-199, 208-228, 25-68-41Page 417 Aug 01/05
CES
R Decompression Panels in the Cargo-Compartment Ceiling-Panels Figure 403C/TASK 25-68-41-991-006-A12 (SHEET 1)
R EFF : 001-049, 051-054, 101-101, 151-154, 201-207, 25-68-41 Page 418 Aug 01/05