Decompression Panels in the Cargo Compartments Figure 402/TASK 25-68-41-991-002
R EFF : 001-049, 051-099, 101-149, 201-299, 25-68-41 Page 407 Aug 01/05
CES
Decompression Panels in the Cargo-Compartment Ceiling-Panels R Figure 403/TASK 25-68-41-991-006- 12 (SHEET 1)
R EFF : 001-049, 051-099, 101-105, 25-68-41Page 408 Aug 01/05
CES
Decompression Panels in the Cargo-Compartment Ceiling-Panels R Figure 403/TASK 25-68-41-991-006- 22 (SHEET 2)
R EFF : 001-049, 051-099, 101-105, 25-68-41Page 409 Aug 01/05
CES
2 Clean the area where you removed the foam-tape:
_
WARNING : MAKE SURE THAT THERE IS A GOOD FLOW OF AIR THROUGH
_______ THE WORK AREA WHEN YOU USE SPECIAL MATERIALS. IF YOU GET ONE OF THESE MATERIALS ON YOUR SKIN, IN YOUR MOUTH OR IN YOUR EYES : -FLUSH IT AWAY WITH A FLOW OF CLEAN WATER FOR BETWEEN 10 AND 15 MINUTES. -GET IMMEDIATE MEDICAL AID IF IRRITATION OCCURS. DO NOT BREATHE THE FUMES FROM THE MATERIAL. DO NOT SMOKE WHEN YOU USE THE MATERIAL. DO NOT USE THE MATERIAL NEAR A FLAME, SPARKS OR SOURCES OF HEAT. THESE MATERIALS ARE DANGEROUS : THEY ARE POISONOUS, FLAMMABLE AND SKIN IRRITANTS.
WARNING : OBEY THE MANUFACTURER'S INSTRUCTIONS WHEN YOU USE
_______ THIS/THESE MATERIAL/S. USE PROTECTIVE CLOTHING, RUBBER GLOVES, GOGGLES AND A MASK.
a Clean the area where you removed the foam-tape (9) with
_ CLEANING AGENTS (Material No. 11-003), a lint-free cotton-cloth MISCELLANEOUS (Material No. 19-003) and a SCRAPER - NON METALLIC
3 Cut the new foam-tape (9) SPECIAL MATERIALS (Material No. 05-
_
066) to the required shape and length.
4 Remove the protective foil from the foam-tape (9).
_
5 Measure a distance of 3.0 mm (0.12 in.) from the edge of the
_ panel-frame to the area where you install the foam tape (9) and make a mark (see DETAIL "F-F").
6 Carefully install the foam-tape (9) in the applicable areas of
_
the decompression-panel (1).
7 Make sure that the distance between the foam-tape (9) and the
_ edge of the panel-frame is 3.0 (0.12 in.) (see DETAIL "F-F").
(e)
Put the latch assemblies (7) in position on the decompression-panel (1) and install the screws (8).
(f)
TORQUE the screws (8) to 0.2 m.daN (17.69 lbf.in).
(g)
Make sure that the latches of the latch assemblies (7) move freely in their housings.
(h)
Put the frame assembly (4) in position on the decompression-panel
(1) and make sure that the flame-retardant material is in the correct position.
(i)
Install the washers (6) and the screws (5).
(4) Install the decompression panel:
(a)
Do an inspection of the component interface and/or the adjacent area.
(b)
Make sure that the decompression panel (1) is clean and in the correct condition.
(c)
Put the decompression-panel (1) in position on the ceiling-panel
(3) and install it.
NOTE : Use a stable force over the full surface of the
____ decompression panel (1) when you push the decompression panel in the related opening of the ceiling panel (3).
(d)
Make sure that the flame-retardant material is in its correct position between the decompression-panel (1) and the ceiling-panel (3), and that:
-
the flame-retardant material is not in position between the foam tape (9) and the ceiling panel (3) (see DETAIL "C-C").
-
the flame-retardant material seals the ceiling panel (3) tightly (see DETAIL "C-C").
中国航空网 www.aero.cn
航空翻译 www.aviation.cn
本文链接地址:A320飞机维护手册 AMM EQUIPMENT/FURNISHINGS 设备4(176)