_
R EFF : 001-049, 051-054, 101-101, 151-154, 25-68-41Page 427 201-207, Aug 01/05
CES
2 Clean the area where you removed the foam-tape:
_
WARNING : MAKE SURE THAT THERE IS A GOOD FLOW OF AIR THROUGH
_______ THE WORK AREA WHEN YOU USE SPECIAL MATERIALS. IF YOU GET ONE OF THESE MATERIALS ON YOUR SKIN, IN YOUR MOUTH OR IN YOUR EYES : -FLUSH IT AWAY WITH A FLOW OF CLEAN WATER FOR BETWEEN 10 AND 15 MINUTES. -GET IMMEDIATE MEDICAL AID IF IRRITATION OCCURS. DO NOT BREATHE THE FUMES FROM THE MATERIAL. DO NOT SMOKE WHEN YOU USE THE MATERIAL. DO NOT USE THE MATERIAL NEAR A FLAME, SPARKS OR SOURCES OF HEAT. THESE MATERIALS ARE DANGEROUS : THEY ARE POISONOUS, FLAMMABLE AND SKIN IRRITANTS.
WARNING : OBEY THE MANUFACTURER'S INSTRUCTIONS WHEN YOU USE
_______ THIS/THESE MATERIAL/S. USE PROTECTIVE CLOTHING, RUBBER GLOVES, GOGGLES AND A MASK.
a Clean the area where you removed the foam-tape (14) with
_ CLEANING AGENTS (Material No. 11-003), a lint-free cotton-cloth MISCELLANEOUS (Material No. 19-003) and a SCRAPER - NON METALLIC.
3 Cut the new foam-tape (14) SPECIAL MATERIALS (Material No. 05-
_
066) to the required shape and length.
4 Remove the protective foil from the foam-tape (14).
_
5 Measure a distance of 3.0 mm (0.12 in.) from the edge of the
_ panel-frame to the area where you install the foam tape (14) and make a mark (see DETAIL "F-F").
6 Carefully install the foam-tape (14) in the applicable areas
_
of the decompression-panel (1).
7 Make sure that the distance between the foam-tape (14) and the
_ edge of the panel-frame is 3.0 mm (0.12 in.) (see DETAIL "F-F").
(e)
Put the latch assemblies (12) in position on the decompression-panel (1) and install the screws (13).
(f)
TORQUE the screws (13) to 0.2 m.daN (17.69 lbf.in).
R EFF : 001-049, 051-054, 101-101, 151-154, 25-68-41Page 428 201-207, Aug 01/05
CES
(g)
Make sure that the latches of the latch assemblies (12) move freely in their housings.
(h)
Put the frame assembly (9) in position on the decompression-panel
(1) and make sure that the flame-retardant material is in the correct position.
(i)
Install the washers (11) and the screws (11).
(5)
Put the spacers (2) and (3), and the protection-devices (4) and (5) in position on the ceiling-panel (8), and install the screws (6).
(6)
Install the decompression panel:
(a)
Do an inspection of the component interface and/or the adjacent area.
(b)
Make sure that the decompression panel (1) is clean and in the correct condition.
(c)
Put the decompression-panel (1) in position on the ceiling-panel
(8) and install it.
NOTE : Use a stable force over the full surface of the
____ decompression panel (1) when you push the decompression panel in the related opening of the ceiling panel (8).
(d)
Make sure that the flame-retardant material is in its correct position between the decompression-panel (1) and the ceiling-panel (8), and that:
-
the flame-retardant material is not in position between the foam tape (14) and the ceiling panel (6) (see DETAIL "C-C").
-
the flame-retardant material seals the ceiling panel (8) tightly (see DETAIL "C-C").
-
the flame-retardant material does not cause a blockage of the latches of the latch assemblies (see DETAIL "D-D").
(e)
Make sure that the position of the decompression panel (1) in the ceiling panel (8) is symmetrical.
(f)
Make sure that all latches (7) of the latch-assemblies are locked.
**ON A/C ALL
Subtask 25-68-41-920-052
C. Replacement of the Decompression Panels in the Partition at FR24
(Ref. Fig. 406/TASK 25-68-41-991-007)
(1)
Remove the screws (2) and the protective panel (1) from the partition (3).
(2)
Remove the decompression panel:
(a)
Push the latches (4) of the latch assemblies back into their housings, against the spring-tension.
(b)
Carefully remove the decompression-panel (5) together with the seal (10) from the partition (3).
(3)
Disassemble the decompression panel:
(a)
Remove the screws (6) and the washers (7).
(b)
Remove the clamps (8) and the latch assemblies (9) from the decompression panel (5).
中国航空网 www.aero.cn
航空翻译 www.aviation.cn
本文链接地址:A320飞机维护手册 AMM EQUIPMENT/FURNISHINGS 设备4(180)