EFF : ALL
25-62-00Page 602
Inflation Reservoir (Pressure Gages) - Component Location Figure 601/TASK 25-62-00-991-001
R EFF : 001-049, 051-099, 101-149, 151-199, 201-299, 401-499, 25-62-00 Page 603 Aug 01/05
CES
**ON A/C 301-399,
Subtask 25-62-00-010-061-A
B. Access to the Inflation Reservoir (1)
(Ref. Fig. 601A/TASK 25-62-00-991-001-A)
(1) Do one of the two applicable steps:
-Open the door of the overhead stowage compartment.
-Or, Push the quick-release fasteners (6) and open the access door (7).
**ON A/C ALL
4. Procedure
_________ R **ON A/C 001-049, 051-099, 101-149, 151-199, 201-299, 401-499,
Subtask 25-62-00-210-050
A. Visual Inspection
(Ref. Fig. 601/TASK 25-62-00-991-001)
(1) Examine the pressure gages (2):
-At the door escape-slides/slide rafts.
NOTE : You can see the pressure gage (2) through the inspection
____
window in the decorative-cover (3).
-And, in the AFT cargo-compartment.
NOTE : FOR 7506MM
____ Use an inspection mirror to let you see the gage (2) on the LH inflation reservoir (1).
(2) Make sure the gages (2) show the correct pressure. NOTE : The cursor is sensitive to temperature changes and moves
____ independently of the gage needle. It reacts to temperature changes faster than the gas expansion in the inflation reservoir (1).
EFF : ALL
25-62-00Page 604
(a) A correct indication is shown when: - The gage needle is in the green cursor (green "GO"band). - Or, to the right of the green cursor.
(b) An incorrect indication is shown when: - The gage needle is to the left of the green cursor.
(c) If the gage (2) shows an incorrect indication: - Wait for temperature conditions to become stable, then examine the gage (2) again. - Or, if the gage (2) continues to show an incorrect indication, replace the escape-slide/slide raft pack-assembly and/or inflation reservoir (1).
(d) Replace the ecsape-slide/slide raft pack-assembly and/or inflation reservoir (1) with these steps:
1_ At the doors: - Remove the escape-slide/slide raft pack-assembly (Ref. TASK 25-62-44-000-002). - Install a new escape-slide/slide raft pack-assembly (Ref. TASK 25-62-44-400-001).
2_ And, in the AFT cargo-compartment: - Remove the inflation reservoir (1) (Ref. TASK 25-62-46-000-001). - Install a new inflation reservoir (1) (Ref. TASK 25-62-46-400-001).
R **ON A/C 301-399,
R Subtask 25-62-00-210-050-A
R R A. Visual Inspection (Ref. Fig. 601A/TASK 25-62-00-991-001-A)
R (1) Examine the pressure gages (2):
R (a) At the door escape-slides/slide rafts.
R R NOTE : You can see the pressure gage (2) through the inspection____ window in the decorative-cover (3).
R R R (b) And, at one of the two applicable locations that follow: - Through the inspection window (4) in the cover (5). - Or, through the opening in the lining (8).
EFF : ALL
25-62-00Page 605
May 01/04
R R Inflation Reservoir (Pressure Gages) - Component Location Figure 601A/TASK 25-62-00-991-001-A12 (SHEET 1)
R EFF : 301-399, 25-62-00 Page 606 May 01/04
CES
R R Inflation Reservoir (Pressure Gages) - Component Location Figure 601A/TASK 25-62-00-991-001-A22 (SHEET 2)
R EFF : 301-399, 25-62-00 Page 607 May 01/04
CES
R (2) Make sure the gages (2) show the correct pressure.
R NOTE : The cursor is sensitive to temperature changes and moves____
R independently of the gage needle. It reacts to temperature
R changes faster than the gas expansion in the inflation
R reservoir (1).
R (a) A correct indication is shown when:
R - The gage needle is in the green cursor (green "GO"band).
R - Or, to the right of the green cursor.
R (b) An incorrect indication is shown when:
R - The gage needle is to the left of the green cursor.
R (c) If the gage (2) shows an incorrect indication:
R - Wait for temperature conditions to become stable, then examine
R the gage (2) again.