 the end stop, of the automatic inflation cable (25), detaches
 fully from the regulator valve assembly. When you disconnect
 the nipple (6) from the mechanism (21), you must retain the
 automatic inflation cable (25) and keep it with the inflation
 reservoir (19).

 

 (4)
 Push in the release stud (7) and disconnect the manual inflation cable (8) from the regulator valve assembly.

 (5)
 Remove and keep the screw (9) and the washer (10) and disconnect the bonding strap (11) from the mounting bracket (24).

 (6)
 Disconnect the electrical connector (12).

 (7)
 Put blanking caps on the disconnected electrical connectors.

 (8)
 Disconnect the inflation hose assembly (13) from the inflation reservoir union (14) on the regulator valve assembly.


 EFF : 301-399, 25-62-49Page 407

May 01/05
R
 CES


 (9) Safety the disconnected hose and union assemblies:
 WARNING : MAKE SURE THAT YOU INSTALL THE PRESSURE SEAL CAPS ON THE

_______ DISCONNECTED HOSE ASSEMBLIES. IF NOT, THE SLIDES CAN BEGIN TO INFLATE AND START TO DEPLOY WHEN THE AIRCRAFT PRESSURIZES DURING FLIGHT. UNWANTED DEPLOYMENT OF THE ESCAPE SLIDES IN FLIGHT CAN CAUSE INJURY AND/OR DAMAGE.
 (a)
 Remove the pressure seal caps from the pocket (4).

 (b)
 Put the pressure seal caps on the disconnected hose and union assemblies.


 (10) Remove the inflation reservoir (19): WARNING : BE CAREFUL WITH THE INFLATION RESERVOIR AND ITS COMPONENTS.
_______ THE RESERVOIR IS AN ALUMINUM BOTTLE WOUND IN KEVLAR FIBERS BONDED WITH EPOXY RESINS, AND IS PRESSURIZED WITH GAS. IF YOU CAUSE DAMAGE TO THE RESERVOIR, THERE IS A RISK OF EXPLOSION. NO DAMAGE IS PERMITTED.
 (a)
 Loosen the clamp nut until you can open the clamp (15), which is adjacent to the regulator valve assembly.

 (b)
 Loosen, but do not open, the reservoir clamp (16). NOTE : A charged inflation reservoir weighs approximately 7.5 kg

____
 (16.5346 lb).


 (c)
 Hold the inflation reservoir (19) and remove the positioning pin


 (17) from the mounting bracket (24).
 NOTE : The positioning pin (17) is attached to the support

____
 bracket (24) by a lanyard (18).

 (d) Remove the inflation reservoir (19).
 (11)
 Do a check of the pocket (4), make sure that it is empty.

 (12)
 Loosen the clamp (26) and remove and retain the pocket (4) and the clamp (26) from the inflation reservoir (19).


 NOTE : The pocket (4) and the clamp (26) are not inflation reservoir
____ component parts; you must install them on the replacement inflation reservoir.
 EFF : 301-399, 25-62-49Page 408

May 01/05
R
 CES  TASK 25-62-49-400-001


 Inflation Reservoir, Escape-Slide - Installation
 1. Reason for the Job
__________________
 Self Explanatory
 2. Job Set-up Information
______________________
 A. Fixtures, Tools, Test and Support Equipment
 -------------------------------------------------------------------------------
REFERENCE  QTY DESIGNATION
 -------------------------------------------------------------------------------
No specific  1 WARNING NOTICE
R No specific  Torque Wrench : range 0.00 to 1.20 m.daN
R (0.00 to 9.00 lbf.ft) No specific Torque Wrench : range 1.00 to 10.00 m.daN
 (8.00 to 75.00 lbf.ft)
 B. Consumable Materials
 -------------------------------------------------------------------------------
REFERENCE  DESIGNATION
 -------------------------------------------------------------------------------
Material No. 19-010  USA AMS 5687
 LOCKWIRE STAINLESS STEEL ANNEALED 0.8MM DIA
 (Ref. 20-31-00)

 C. Referenced Information
 -------------------------------------------------------------------------------
REFERENCE  DESIGNATION
 -------------------------------------------------------------------------------
20-28-00-912-004  Electrical Bonding of Components With Conductive Bolts and Screws and Bonding Straps in the Fuselage and in the Wings (this does not include the tanks)-
24-42-00-861-001 Energize the Ground Service Network from the External Power 24-42-00-862-001 De-energize the Ground Service Network Supplied from the External Power 25-62-00-210-001 Check Pressure at Door Escape-Slide/Slide Raft Pressure Gage (if not connected to CIDS)