 (b)  Make sure there is no voltage between pins 1 and 2 of the electrical connector.
 NOTE: Connect a 10 kohm resistor across the meter to remove
____ any stray voltage from the electrical connector.
 EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. ú

 26-21-01
 ALL  ú ú 07 Page 421 ú Oct 18/00
BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details.
A
747-400 MAINTENANCE MANUAL
 S 864-184
 (23) Push and hold the manual override pressure switch, or insert the hex key into the bottle pressure switch cam and turn the key with a maximum of 5.7 pound-inch on the APU fire bottle.
 (a)  Make sure the APU BTL DISCH light on the fire control module, M7326 (P5), comes on.
 S 864-185
 (24) Release the manual override pressure switch, or the hex key.
 (a)  Make sure the APU BTL DISCH light goes off on the fire control module, M7326 (P5).
 S 864-186
 (25) Close these circuit breakers:
 (a)  P6 Main Power Distribution Panel
 1) 6H5 FIRE EXTINGUISHER APU
 2) 6L4 FLIGHT DECK LIGHT CAPT IND

 S 864-187
 (26) Push and hold the TEST 1 switch on the squib test module, M7327, on the P461 panel.
 (a)  Make sure the squib indicating light for the APU comes on (green).
 S 864-188
 (27) Release the TEST 1 switch.
 (a)  Make sure the indicating light goes off.
 S 864-189
 (28) Push and hold the TEST 2 switch on the squib test module, M7327.
 (a)  Make sure the squib indicating light for the APU comes on (green).
 S 864-190
 (29)
 Release the TEST 2 switch.

 (a)  Make sure the squib indicating light goes off.

 J.
Cargo Bay Test Set Up


 S 864-191
 (1)  Open these circuit breakers:
 (a)  P6 Main Power Distribution Panel
 1) 6H6 FIRE EXTINGUISHER LOWER CARGO

 EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. ú

 26-21-01
 ALL  ú ú 08 Page 422 ú Feb 15/99
BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details.
A
747-400 MAINTENANCE MANUAL
 S 034-192
 (2)  Disconnect these electrical connectors in the lower forward cargo compartment:
 __________________BOTTLE ELECTRICAL CONNECTOR BOTTLE A FWD SQUIB DM7906B BOTTLE A AFT SQUIB DM7906C BOTTLE B FWD SQUIB DM7907B BOTTLE B AFT SQUIB DM7907C BOTTLE C FWD SQUIB DM7908B BOTTLE C AFT SQUIB DM7908C BOTTLE D FWD SQUIB DM6742B BOTTLE D AFT SQUIB DM6742C
 S 494-195
 WARNING:_______PUT THE PROTECTIVE COVERS ON THE FIRE BOTTLE SQUIBS. IF YOU DO NOT PUT THE PROTECTIVE COVERS ON THE FIRE BOTTLE SQUIBS, THE FIRE BOTTLE CAN RELEASE ITS CONTENTS SUDDENLY AND CAUSE INJURY TO PERSONS.
 CAUTION:_______DO NOT PUT SHUNT PLUGS ON THE FIRE BOTTLE SQUIBS. THE SHUNT PLUGS CAN CAUSE DAMAGE TO THE SQUIB PINS.
 (3)  
Put the protective covers on all the fire bottle squibs.

 S 864-196

 (4)  
Close these circuit breakers:


 (a)  P6 Main Power Ditribution Panel
 1) 6H6 FIRE EXTINGUISHER LOWER CARGO

 S 864-197
 (5)  Open this circuit breaker:
 (a)  P7 panel 1) 7F23 LANDING GEAR DSP & CONT ALTN 2) AIRPLANES WITH DUAL CARGO HEAT OR AFT CARGO AIR
 CONDITIONING; 180E9 CARGO VENT FLAPPER
 S 864-201
 (6)  Make sure the CARGO FIRE ARMED and DISCH lights on the fire control module M7326 on the P5 pilot's overhead panel are off.
 K. Forward Cargo Bay Fire Bottle Test
 S 484-202
 (1)  Connect electrical connector DM7906B, for the bottle A forward squib, to the squib test box.
 EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. ú

 26-21-01
 ALL  ú ú 07 Page 423 ú Oct 18/00
BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details.
A
747-400 MAINTENANCE MANUAL
 
中国航空网 www.aero.cn
航空翻译 www.aviation.cn
本文链接地址:747-400 AMM 飞机维护手册 防火 FIRE PROTECTION 2(69)