(10)
Make sure the air or nitrogen flows freely from nozzles located in the forward compartment ceiling at STA 536, RBL 6.50 and STA 756, RBL 6.50.
S 715-139
(11)
Make sure the air or nitrogen does not flow from the forward compartment jet nozzles at STA 743, RBL 6.50 (approximately) and STA 523, RBL 6.50 .
S 715-140
(12)
Make sure the air or nitrogen does not flow freely from the nozzles located in the aft compartment ceiling at STA 1736, RBL 6.50 and STA 1723, RBL 6.50 (approximately).
EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. ú
26-23-00
ALL ú ú 04 Page 516 ú Oct 15/98
BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details.
A
747-400 MAINTENANCE MANUAL
S 715-141
(13)
Make sure the DISCH caution light on the fire control module M7326 (P5) comes on.
S 865-083
(14)
Remove the pressure from the halon distribution tubing.
S 085-084
(15)
Disconnect the air or nitrogen from the forward halon distribution tubing.
S 035-142
(16)
Connect and tighten the hose to the forward discharge port of the bottle A (AMM 26-23-01/401).
S 435-085
(17)
Remove the cap from the hose leading to the forward cargo
compartment halon distribution tubing.
S 035-143
(18)
Connect and tighten the hose to the forward discharge port of the bottle B (AMM 26-23-01/401).
S 865-086
(19)
Push the reset button on S1890 (STA 926, RBL 120, WL 180) pressure switch.
S 715-132
(20)
Make sure the DISCH caution light on the fire control module M7326 (P5) goes off.
G. Aft Non-Metered Discharge Line Test
S 215-088
(1) Make sure all halon distribution tubings from the halon bottle shelf to the lower cargo compartment are not loosely connected or disconnected.
S 035-089
CAUTION:_______DO NOT PRESSURIZE THE HALON BOTTLES. DAMAGE TO DISCHARGE PORTS CAN OCCUR.
(2)
Disconnect the discharge hose from the aft discharge port of the bottle A (M7906) (STA 950, RBL 102).
S 035-174
(3)
Disconnect the discharge hose from the aft discharge port of bottle B (M7907) (STA 950, RBL 102).
EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. ú
26-23-00
ALL ú ú 03 Page 517 ú Feb 18/01
BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details.
A
747-400
MAINTENANCE MANUAL
S 435-090
(4) Connect dry plant air or nitrogen to the open hose that was disconnected from the aft discharge port of the bottle A. Use an appropriate connector from the adaptor kit.
(5) S 865-133Pressurize the halon distribution tubing to 15 to 50 psig.
(6) S 715-134Make sure the air or nitrogen flows freely from the hose that was disconnected from the aft discharge port of the bottle B.
(7) S 865-135Decrease the pressure to zero psig.
中国航空网 www.aero.cn
航空翻译 www.aviation.cn
本文链接地址:747-400 AMM 飞机维护手册 防火 FIRE PROTECTION 2(120)