(1)
AMM 20-41-01/201, Electrostatic Discharge Sensitive Devices
(2)
AMM 27-81-00/201, Leading Edge Flap SystemAccess
(1)
Location Zone 221 Control Cabin LH 222 Control Cabin RH 514 Kruger Flap No. 1, Left 614 Kruger Flap No. 1, Right
(2)
Location Zone 221 Control Cabin LH 222 Control Cabin RH
CF80C2 Engines:
514 Kruger Flap No. 1, Left
614 Kruger Flap No. 1, Right
RB211-524 Engines:
411 Nose Cowl Engine No. 1
421 Nose Cowl Engine No. 2
431 Nose Cowl Engine No. 3
441 Nose Cowl Engine No. 4
EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. ú
26-21-01
ALL ú ú 04 Page 406 ú Oct 18/00
BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details.
A
747-400 MAINTENANCE MANUAL
F. Engine fire handle functions
S 864-084
(1) Supply electrical power (AMM 24-22-00/201).
S 014-086
WARNING: MAKE SURE THAT PERSONS AND EQUIPMENT ARE CLEAR OF THE LE AND TE
_______ FLAPS AND FLAP DRIVE MECHANISMS BEFORE YOU MOVE THE FLAP CONTROL LEVER. WITH HYDRAULIC POWER REMOVED, THE FLAPS WILL MOVE AUTOMATICALLY BY ELECTRICAL POWER WHEN YOU MOVE THE FLAP CONTROL LEVER. IF THE FLAPS MOVE INJURY TO PERSONS CAN OCCUR.
WARNING: INSTALL LOCKS TO PREVENT MOVEMENT OF THE FLAPS
_______ (AMM 27-81-00/201). IF THE LOCKS ARE NOT INSTALLED INJURY TO PERSONS CAN OCCUR.
(2)
Extend the wing leading edge flaps to get access to the engine bottle electrical connectors.
S 434-306
(3)
Install safety locks on all extended leading edge flaps where persons are near (Ref 27-81-00/201).
S 864-088
(4)
Open these circuit breakers and attach DO-NOT-CLOSE tags:
NOTE: After the fire bottle circuit breakers are open, one person
____ can continue with the procedure while another person is disconnecting the fire bottle connectors.
(a) P6 Main Power Distribution Panel
1) 6H1 FIRE EXTINGUISHER ENG 1&3 B
2) 6H2 FIRE EXTINGUISHER ENG 1&3 A
3) 6H3 FIRE EXTINGUISHER ENG 2&4 B
4) 6H4 FIRE EXTINGUISHER ENG 2&4 A
S 864-089
(5) Disconnect the bottle electrical connectors shown in the table.
~...............................................
| WING | BOTTLE | ELECTRICAL CONNECTOR |
.................................................
| LEFT | A | DM228B, DM228C |
| | B | DM229B, DM229C |
| RIGHT | A | DM230B, DM230C |
| | B | DM231B, DM231C |
2........…............….........................1
EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. ú
26-21-01
ALL ú ú 04 Page 407 ú Oct 18/00
BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details.
A
747-400 MAINTENANCE MANUAL
S 494-091
WARNING:_______ PUT PROTECTIVE COVERS ON THE FIRE BOTTLE SQUIBS. IF YOU DO NOT
PUT PROTECTIVE COVERS ON THE FIRE BOTTLE SQUIBS, THE FIRE
BOTTLES CAN RELEASE THEIR CONTENTS SUDDENLY AND CAUSE INJURY TO
PERSONS.
CAUTION:_______DO NOT PUT SHUNT PLUGS ON THE FIRE BOTTLE SQUIBS. THE SHUNT PLUGS CAN CAUSE DAMAGE TO THE SQUIB PINS.
(6)
Put the protective cover on all the fire bottle squibs.
S 864-093
(7)
Make sure the engine fire handles are pushed in.
S 864-094
(8)
Make sure all these switches on the fuel management control module, M154 (P5 pilots' overhead panel) are in the off position.
(a)
Boost pumps and override/jettison pumps (the white ON indication light in each switch does not show).
(b)
Fuel crossfeed valves (the flowbar indication in each switch does not show).
S 864-095
(9) Make sure the FUEL CONTROL switch for engine 1, 2, 3 and 4 are in the CUTOFF position.
S 864-096
WARNING: OPEN THE APPLICABLE CIRCUIT BREAKER FOR THE ENGINE IGNITION
_______ BEFORE YOU OPEN THE CIRCUIT BREAKER FOR THE ENGINE FUEL CONTROL VALVE. AN AUTOMATIC FIRING OF THE IGNITER PLUGS WILL OCCUR WHEN:
中国航空网 www.aero.cn
航空翻译 www.aviation.cn
本文链接地址:747-400 AMM 飞机维护手册 防火 FIRE PROTECTION 2(62)