• 热门标签

当前位置: 主页 > 航空资料 > 机务资料 >

时间:2011-04-10 09:48来源:蓝天飞行翻译 作者:航空
曝光台 注意防骗 网曝天猫店富美金盛家居专营店坑蒙拐骗欺诈消费者

 (4)  
Put a protective cover on the fire bottle squib.

 S 024-024

 (5)  
Remove the squib and the ground lug assembly.


 NOTE: Keep the ground lug assembly for the subsequent installation.
____
 TASK 26-22-02-404-005
 3.  Install Discharge Cartridge (Squib) (Fig. 401)___________________________________
 A. Equipment
 (1)  Voltmeter - 28 vdc
 EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. ú

 26-22-02
 ALL  ú ú 03 Page 403 ú Oct 18/01
BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details.
A
747-400
MAINTENANCE MANUAL

 B. References
 (1)  
AMM 20-41-02/201, Electrostatic Discharge Sensitive Devices

 (2)  
AMM 24-22-00/201, Manual Control

 (3)  
IPC 26-22-11 Fig. 01

 (4)  
WDM 26-22-11

 (5)  
SSM 26-22-01

 C.
Access

 (1)  
Location Zone
 315 Area Aft of Stablizer Box Compartment, LH


 (2)  
Access Panel
 315AL Access Door


 D.
Procedure


 S 864-041
 WARNING:_______DO NOT TOUCH THE PNEUMATIC DUCTS WHEN THEY ARE HOT. WHEN THE DUCTS ARE HOT THEY CAN CAUSE INJURY TO PERSONS.
 WARNING: DO NOT TOUCH THE SQUIB BEFORE YOU DO THE PROCEDURES FOR DEVICES
_______ THAT ARE SENSITIVE TO ELECTROSTATIC DISCHARGE. ELECTROSTATIC DISCHARGE CAN CAUSE THE FIRE BOTTLES TO RELEASE ITS CONTENTS SUDDENLY AND CAUSE INJURY TO PERSONS AND DAMAGE TO EQUIPMENT.
 (1)  
Before you touch the squib, do the procedure for devices that are sensitive to electrostatic discharge (AMM 20-41-02/201).

 S 424-023

 (2)  
Install the squid, and ground lug assembly in the bottle.

 S 424-054

 (3)  
Torque the squib to 90-100 inch-pounds.

 S 914-008

 (4)
Install a lockwire between the squib and the discharge outlet.

 S 434-011

 (5)  
Do these steps to connect the electrical connector DM103B to the squib.


 (a)  If a protective cover is installed, remove the protective cover.
 EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. ú

 26-22-02
 ALL  ú ú 02 Page 404 ú Oct 18/01
BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details.
A
747-400
MAINTENANCE MANUAL

 CAUTION: IF A SHUNT PLUG IS INSTALLED, PULL THE SHUNT PLUG STRAIGHT
_______ OFF THE FIRE BOTTLE SQUIB. IF YOU TWIST OR TURN THE SHUNT PLUG, YOU CAN CAUSE DAMAGE TO THE SQUIB PINS.
 (b)  If a shunt plug is installed, pull the shunt plug straight off the squib and discard the shunt plug.
 NOTE: Shunt plugs should not be used to cover the fire bottle
____ squibs because they can cause damage to the squib pins.
 WARNING: MAKE SURE THERE IS NO VOLTAGE AT THE ELECTRICAL CONNECTOR.
_______ IF THERE IS A VOLTAGE AT THE ELECTRICAL CONNECTOR, THE SQUIB CAN RELEASE ITS CONTENTS SUDDENLY AND CAUSE INJURY TO PERSONS.
 (c)  Make sure there is no voltage between pins 1 and 2 of the electrical connector.
 NOTE: Connect a 10 Kohm resistor across the meter
____ to remove any stray voltage from the electrical connector.
 (d)  
Make sure the squib pins are not bent or damaged.

 (e)  
Make sure the electrical connector is not damaged.


 NOTE: The squib pins can cause damage to the electrical
____ connector if the pins do not enter the connector receptacles.
 (f)  
Connect the electrical connector to the fire bottle squib.

 (g)  
Do the steps that follow to make sure you did not bend or damage the squib pins.


 NOTE: This step is necessary because the pins are most likely
____ to be damaged the first time an electrical connector is connected to the squib.
 1) Disconnect the electrical connector from the fire bottle
 squib. 2) Make sure the squib pins are not bent or damaged. 3) Make sure the electrical connector is not damaged.
 NOTE: The squib pins can cause damage to the electrical
 
中国航空网 www.aero.cn
航空翻译 www.aviation.cn
本文链接地址:747-400 AMM 飞机维护手册 防火 FIRE PROTECTION 2(107)