737-300/400/500MAINTENANCE MANUAL
RECIRCULATION FILTER
SEEA B
MIX MANIFOLD
CONDITIONED AIR SUPPLY DUCT
FASTENERS (14)  FASTENERS (14) 
1/4 TURN  1/4 TURN
AIRFLOW  AIRFLOW 
FILTER  FILTER  PREFILTER 
SUPPORT  SUPPORT 
HIGH EFFICIENCY 
FILTER  PARTICULATE AIR 
(HEPA) FILTER 

ACCESS  ACCESS
DOOR  DOOR
RECIRCULATION RECIRCULATION FAN FAN
RECIRCULATION FILTER RECIRCULATION FILTER (ONE-PIECE FILTER) (TWO-PIECE FILTER)
A B
Recirculation Fan Filter Figure 401
G59361
 EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. ú

 21-21-23
 ALL  ú ú 02 Page 402 ú Jul 15/97
BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details.
A 737-300/400/500MAINTENANCE MANUAL
 TASK 21-21-23-404-083
 3.  AIRPLANES WITH A SINGLE FILTER INSTALLATION; Recirculation Fan Filter Installation (Fig. 401)
_____________________________________
 A.  References
 (1)  AMM 12-31-01/201, Zone Diagrams
 B.  Access
 (1)  Location Zone (AMM 12-31-01/201)
 210, Air-Conditioning Distribution Bay

 C.  Procedure
 S 424-075
 (1)  Install the recirculation fan filter:
 (a)  
Install the filter.

 (b)  
Install the access door.

 (c)  
Use the fasteners to attach the access door to the filter support (14 Locations).


 S 414-078
 (2)  Install this access panel:
 (a)  Access Panel, Right - Forward Cargo Compartment Aft Bulkhead
 S 864-081
 (3) Remove the DO-NOT-OPERATE identifiers if no longer necessary.
 TASK 21-21-23-004-024
 4.  AIRPLANES WITH A TWO PIECE FILTER INSTALLATION; Recirculation Fan Prefilter Removal (Fig. 401)
___________________________________
 A.  General
 (1)  One recirculation fan filter installation is installed in the air-conditioning distribution bay.
 B.  References
 (1)  AMM 12-31-01/201, Zone Diagrams
 C.  Access
 (1)  Location Zone (AMM 12-31-01/201)
 210, Air-Conditioning Distribution Bay

 D.  Procedure
 S 864-002
 (1)  Set these switches to the OFF position and attach DO-NOT-OPERATE identifiers:
 (a)  P5-10 Air-Conditioning Module
 1) R PACK
 2) L PACK
 3) RECIRC FAN

 EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. ú

 21-21-23
 ALL  ú ú 02 Page 403 ú Nov 12/99
BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details.
A
737-300/400/500MAINTENANCE MANUAL
 S 014-003
 (2)  Remove this access panel:
 (a)  Access Panel, Right - Forward Cargo Compartment Aft Bulkhead
 S 024-014
 (3)  Remove the recirculation fan prefilter:
 (a)  
Release the fasteners which hold the access door to the filter support (14 Locations).

 (b)  
Remove the access door.

 (c)  
Remove the prefilter.


 NOTE: If only the prefilter is to be replaced, vacuum the
____ top of the HEPA filter.
 (d)  Do this step if you only want to replace the prefilter media:
 1)  Use a twisting motion to remove the media from the prefilter frame.
 TASK 21-21-23-404-015
 5.  AIRPLANES WITH A TWO PIECE FILTER INSTALLATION; Recirculation Fan Prefilter Installation (Fig. 401)
________________________________________
 A.  References
 (1)  AMM 12-31-01/201, Zone Diagrams
 B.  Access
 (1)  Location Zone (AMM 12-31-01/201)
 210, Air-Conditioning Distribution Bay

 C.  Procedure
 S 424-050
 (1)  Install the recirculation fan prefilter media:
 NOTE: This step is necessary only if you are installing filter
____
 media into the prefilter frame.

 CAUTION:_______MAKE SURE YOU HANDLE THE FILTER MEDIA CAREFULLY. THE FILTER MEDIA CAN BE EASILY PUNCTURED DURING INSTALLATION.
 
中国航空网 www.aero.cn
航空翻译 www.aviation.cn
本文链接地址:737-300 400 500 AMM 飞机维护手册 空调 AIR CONDITIONING 1(35)