 S 715-350
 (10) Do this check with the pack in AUTO (Right Pack):
 (a)  
Set the R PACK switch to AUTO.

 (b)  
When the APU EGT is stable, write down the EGT as
 Temperature #5.


 (c)  
AIRPLANES WITH GARRETT APU MODELS GTCP85-129C,-129E,-129F; Make sure that the difference between the Temperature #1 APU EGT and the Temperature #5 APU EGT is between the MINIMUM and MAXIMUM curves shown in Figure 502.

 (d)  
AIRPLANES WITH GARRETT APU MODELS GTCP85-129H,-129J,-129K; Make sure that the difference between the Temperature #1 APU EGT and the Temperature #5 APU EGT is |40°C of the APU EGT shown in Figure 502 for the LOW FLOW curve.

 (e)  
Make sure that the duct pressure shown on the P5-10 panel is more than 27 psi.

 (f)  
Move the R PACK switch to OFF.


 EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. ú

 21-51-00
 ALL  ú ú 01 Page 534 ú Mar 15/98
BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details.
A
737-300/400/500MAINTENANCE MANUAL
 (g)  Connect the electrical connector, D712, to the 35°F control sensor on the right water separator.
 NOTE: The 35°F control valve will close.
____
 F. Put the Airplane Back to Its Usual Condition
 S 865-282
 (1)
Shutoff the APU if it is not necessary (AMM 49-11-00/201).

 S 865-283

 (2)  
Move the ISOLATION VALVE switch to CLOSE.

 S 865-284

 (3)  
Remove the electrical power if it is not necessary
 (AMM 24-22-00/201).


 S 415-285

 (4)  
Close the bay doors to the air conditioning equipment.


 TASK 21-51-00-715-337
 8.  Operational Test - Air Cycle System - 35°F Control System Test______________________________________________________________
 A. General
 (1)  
This procedure has the steps to test the 35°F control system.

 (2)  
This procedure supplies a quick check of the system performance for scheduled maintenance checks and to troubleshoot flight operation problems.


 B. References
 (1)  
AMM 21-51-21/701, Heat Exchangers

 (2)  
AMM 21-61-00/101, Temperature Control System

 (3)  
AMM 24-22-00/201, Electrical Power

 (4)  
AMM 49-11-00/201, APU Power Plant


 C. Access
 (1)  Location Zones
 101 Control Cabin - Left
 102 Control Cabin - Right
 210 Air Conditioning Distibution Bay
 212 Left Air Conditioning Equipment Bay
 214 Right Air Conditioning Equipment Bay

 EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. ú

 21-51-00
 ALL  ú ú 01 Page 535 ú Mar 15/96
BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details.
A 737-300/400/500MAINTENANCE MANUAL
APU ~EGT (`C)
310
300
290
280
270
260

MAXIMUM MINIMUM
250
240
230
220
210
200
190
180
170

160
150
140
130
120
110

-20 -15 -10 -5 0 +5 +10 +15 +20 +25 +30 +35 +40
AMBIENT TEMPERATURE (`C)
NOTE:  THESE LIMITS ARE FOR SEA LEVEL STATIC OPERATION. FOR HIGHER ELEVATIONS, RAISE EACH LINE BY 5`C PER 1,000 FEET.
Changes in APU EGT (with One A/C Pack Flow) per Changes in Ambient Temperature Figure 502 (Sheet 1)
EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. AIRPLANES WITH GARRETT APU MODELS ú

 21-51-00
 GTCP85-129C,-129E,-129F  ú ú 01 Page 536 ú Mar 15/95
BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details.
A 737-300/400/500MAINTENANCE MANUAL
320
280
240
200
160
120


HIGH FLOW 


LOW FLOW 
 