• 热门标签

当前位置: 主页 > 航空资料 > 机务资料 >

时间:2011-04-01 08:32来源:蓝天飞行翻译 作者:航空
曝光台 注意防骗 网曝天猫店富美金盛家居专营店坑蒙拐骗欺诈消费者

 (9)  Do this check of the flow control and shutoff valve (Right Pack):
 (a)  Disconnect the electrical connector, D394, from the right pack flow control and shutoff valve.
 NOTE: The flow control valve will move to the closed position.
____
 (b)  
Make sure that the APU EGT decreases again.

 (c)  
Make sure the flow control and shutoff valve for the right pack moves towards the closed position.

 (d)  
Connect the electrical connector, D394, to the right pack flow control and shutoff valve.

 (e)  
Make sure the right flow control and shutoff valve moves towards the open position.


 EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. ú

 21-51-00
 ALL  ú ú 01 Page 532 ú Mar 15/98
BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details.
 (f)

(g)

(h)

(i)

(j)


A
737-300/400/500MAINTENANCE MANUAL
When the APU EGT is stable, write down the APU EGT as
 Temperature #4.
AIRPLANES WITH GARRETT APU MODELS GTCP85-129C,-129E,-129F;
 Make sure that the difference between the Temperature #1 APU
 EGT and the Temperature #4 APU EGT is between the MINIMUM and
 MAXIMUM curves shown in Figure 502.
AIRPLANES WITH GARRETT APU MODELS GTCP85-129H,-129J,-129K;
 Make sure that the difference between the Temperature #1 APU
 EGT and the Temperature #4 APU EGT is |40°C of the APU EGT
 shown in Figure 502 for the HIGH FLOW curve.
When the SUPPLY DUCT temperature is stable, write down the
 SUPPLY DUCT temperature.
AIRPLANES WITH TEMPERATURE INDICATION IN FAHRENHEIT;
 Make sure that the second SUPPLY DUCT temperature is less than
 36°F above the ambient air temperature.

 NOTE: A higher duct temperature is a sign of poor performance

____ of the primary heat exchanger when the pack flow and turbofan operation is normal. The steps which follow can temporarily increase the performance of the primary heat exchanger.
 1)  If the SUPPLY DUCT temperature is more then 36°F above the ambient air temperature, then do these steps: a) Move the R PACK switch to OFF and attach a
 DO-NOT-OPERATE tag.
 b) Clean the heat exchangers (AMM 21-51-21/701).

 NOTE: If the primary heat exchanger needs to be
____ cleaned, the secondary heat exchanger will also need to be cleaned. The primary and the secondary heat exchangers are cleaned together in AMM 21-51-21/701.
 c)  Remove the DO-NOT-OPERATE tag and move the R PACK switch to HIGH.
 d)  Make sure that the second SUPPLY DUCT temperature is less than 36 degrees F above the ambient air temperature.
 e)  Replace the primary heat exchanger if the second SUPPLY DUCT temperature is more than 36 degrees F above the ambient air temperature.
 EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. ú

 21-51-00
 ALL  ú ú 01 Page 533 ú Mar 15/98
BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details.
A 737-300/400/500MAINTENANCE MANUAL
 (k)  AIRPLANES WITH TEMPERATURE INDICATION IN CELSIUS; Make sure that the second SUPPLY DUCT temperature is less than 20°C above the ambient air temperature.
 NOTE: A higher duct temperature is a sign of poor performance
____ of the primary heat exchanger when the pack flow and turbofan operation is normal. The steps which follow can temporarily increase the performance of the primary heat exchanger.
 1)  If the SUPPLY DUCT temperatue is more then 20°C above the ambient air temperature, then do these steps: a) Move the R PACK switch to OFF and attach a
 DO-NOT-OPERATE tag. b) Clean the heat exchangers (Ref 21-51-21/701).
 NOTE: If the primary heat exchanger needs to be
____ cleaned, the secondary heat exchanger will also need to be cleaned. The primary and the secondary heat exchangers are cleaned together in AMM 21-51-21/701.
 c) Remove the DO-NOT-OPERATE tag and move the R PACK switch to HIGH. d) Make sure that the second SUPPLY DUCT temperature is less than 20°C above the ambient air temperature.
 e)  Replace the primary heat exchanger if the second SUPPLY DUCT temperature is more than 20°C above the ambient air temperature.
 
中国航空网 www.aero.cn
航空翻译 www.aviation.cn
本文链接地址:737-300 400 500 AMM 飞机维护手册 空调 AIR CONDITIONING 1(147)