A 737-300/400/500MAINTENANCE MANUAL
 (5)  S 714-028Remove the conditioned air from the air conditioning system (Ref 21-00-00/201).
 (6)  S 714-029Make sure the swing check valve is almost open.
 (7)  S 414-031Close the access door to the ground service conditioned air connector.
 (8)  S 414-030Install the center panel to the aft bulkhead in the forward cargo compartment which you removed to get access to the duct and check valve assembly.

 EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. ú

 21-21-12
 ALL  ú ú 01 Page 407 ú Jul 15/91
BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details.
A
737-300/400/500MAINTENANCE MANUAL
 RECIRCULATION FAN - TROUBLE SHOOTING
____________________________________
 1.  General_______
 A.  Main distribution recirculation fan trouble shooting can be accomplished without operating the air conditioning packs and no special equipment is needed.
 B.  Intermittent or cycling operation of recirculation fan indicates fan overheat or defective overheat switch. Remove and replace recirculation fan.
 2.  Prepare for Trouble Shooting____________________________
 A.  Check following circuit breakers on P6 panel are closed.
 (1)
CABIN AIR RECIRC FAN

 (2)
RECIRC FAN CONTROL

 (3)
All air conditioning circuit breakers.

 (4)
RECIRC FAN ENERGIZED


 B.  Open access 3304 and 3404 to gain access to pack flow control and shutoff valves in air conditioning bay.
 C.  Provide electrical power (Ref 24-22-00, MP).
 EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. ú

 21-21-22
 ALL  ú ú 01 Page 101 ú Jun 25/84
BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details.
A
737-300/400/500MAINTENANCE MANUAL
1.Cabin Air Recirculation Fan does not Run when One Pack Switch OFF

EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. ú

 21-21-22
 ALL  ú ú 01 Page 102 ú Jun 25/84
BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details.
A
737-300/400/500MAINTENANCE MANUAL
 RECIRCULATION FAN - REMOVAL/INSTALLATION
________________________________________
 1.  General_______
 A.  Two tasks are supplied in this procedure. The first task is the removal of the recirculation fan. The second task is the installation of the recirculation fan.
 B.  The recirculation fan is installed in the air-conditioning distribution bay.
 TASK 21-21-22-004-001
 2.  Remove The Recirculation Fan (Fig. 401)____________________________
 A.  References
 (1)  
12-31-01/201, Zone Diagrams

 (2)  
24-22-00/201, Manual Control


 B.  Access
 (1)  Location Zone (Ref 12-31-01/201)
 (a)  210, Air-Conditioning Distribution Bay
 C.  Procedure
 S 864-002
 (1)
Supply electrical power to the airplane (Ref 24-22-00/201).

 S 864-003

 (2)  
Set the RECIRC FAN switch on the P5-10 Air-Conditioning Module to the OFF position.

 S 864-004

 (3)
Open these circuit breakers and attach DO-NOT-CLOSE identifiers:


 (a)  P6-4 Load Control Center Circuit Breaker Panel 1) CABIN AIR RECIRCULATION FAN 2) RECIRC FAN CONT
 S 014-029
 (4)  Remove these access panels:
 (a)  
Access Panel, Center - Forward Cargo Compartment, Aft Bulkhead

 (b)  
Access Panel, Right - Forward Cargo Compartment, Aft bulkhead