• 热门标签

当前位置: 主页 > 航空资料 > 机务资料 >

时间:2011-04-01 08:32来源:蓝天飞行翻译 作者:航空
曝光台 注意防骗 网曝天猫店富美金盛家居专营店坑蒙拐骗欺诈消费者

 (4)  S 864-020Remove the DO-NOT-CLOSE identifiers and close these circuit breakers on the P6-3 panel: (a) All the circuit breakers on the CONTROL CABIN LIGHTING module (b) 6C18 LANDING GEAR - AIR/GND RELAY & LTS
 (5)  S 864-027Remove the DO-NOT-CLOSE identifiers and close these circuit breakers on the P18-2 panel: (a) 18A8 No. 1 AIR DATA COMPUTER AC (b) 18A9 NO. 1 AIR DATA COMPUTER (25 VAC)
 (6)  S 714-007Do a test of the pressurization control system (AMM 21-31-00/201).

 EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. ú

 21-31-21
 ALL  ú ú 01 Page 404 ú Mar 12/01
BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details.
A
737-300/400/500MAINTENANCE MANUAL
 DELTA P MODULE - REMOVAL/INSTALLATION
_____________________________________
 1.  General_______
 A.  This procedure has two tasks. The first task gives instructions for the removal of the delta P module. The second task gives instructions for the installation of the delta P module.
 B.  The delta P module is on the top shelf of the E1 rack in the E/E equipment compartment (Fig. 401).
 TASK 21-31-22-004-003
 2.  Delta P Module Removal (Fig. 401)______________________
 A.  References
 (1)  
20-10-07/201, E/E Rack-Mounted Components

 (2)  
21-31-21/401, Pressure Controller


 B.  Access
 (1)  
Location Zone
 205 Electronic Compartment


 (2)  
Access Panel
 1201L Electronic Equipment Access Door

 

 C.  Procedure
 S 864-008
 (1)  Open these circuit breakers on the P6 panel and attach DO-NOT-CLOSE tags:
 (a)  
MAN DC

 (b)  
STBY DC

 (c)  
AUTOMATIC DC

 (d)  
AUTOMATIC AC

 (e)  
MAN AC

 (f)  
STBY AC

 (g)  
All the circuit breakers on the CONTROL CABIN LIGHTING module

 (h)  
LANDING GEAR LIGHTS


 S 864-009
 (2)  Open the No. 1 AIR DATA COMPUTER circuit breaker on the P18 panel and attach a DO-NOT-CLOSE tag.
 EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. ú

 21-31-22
 ALL  ú ú 02 Page 401 ú Nov 15/94
BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details.
A 737-300/400/500MAINTENANCE MANUAL

A


Delta P Module Installation
Figure 401

EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. ú

 21-31-22
 ALL  ú ú 01 Page 402 ú Jul 15/92
BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details.
A
737-300/400/500MAINTENANCE MANUAL
 S 024-010
 (3)  
Remove the pressure controller (Ref 21-31-21/401).

 S 014-018

 (4)  
Remove one of these components from the E1-1 shelf, as necessary, to gain access to the delta P module:

 (a)  
AUTO-SLAT CMPTR NO. 2

 (b)  
DGTL STALL WRN CMPTR NO. 2

 (c)  
STALL MGMT CMPTR NO. 2

 (d)  
CABIN TEMP CONT module

 


 S 014-001
 (5)
Get access to the delta P module on the top shelf of the E1 rack.

 S 024-002

 (6)  
Remove the delta P module (Ref 20-10-07/201).

 (a)  
Disconnect the electrical connector, D1872, from the delta P module.

 (b)  
Remove the screwlocks, lockwashers, standoffs, and nuts that attach the delta P module to the E1-1 shelf.

 (c)  
Remove the delta P module.

 


 TASK 21-31-22-404-004
 3.  Delta P Module Installation (Fig. 401)___________________________
 A. Equipment
 (1)  Multimeter
 B. References
 (1)  
20-10-07/201, E/E Rack-Mounted Components
 
中国航空网 www.aero.cn
航空翻译 www.aviation.cn
本文链接地址:737-300 400 500 AMM 飞机维护手册 空调 AIR CONDITIONING 1(102)