• 热门标签

当前位置: 主页 > 航空资料 > 机务资料 >

时间:2011-04-01 08:32来源:蓝天飞行翻译 作者:航空
曝光台 注意防骗 网曝天猫店富美金盛家居专营店坑蒙拐骗欺诈消费者

 21-21-22
 ALL  ú ú 02 Page 401 ú Jul 15/90
BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details.
A 737-300/400/500MAINTENANCE MANUAL


Recirculation Fan
Figure 401

EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. ú

 21-21-22
 ALL  ú ú 01 Page 402 ú Feb 20/84
BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details.
A
737-300/400/500MAINTENANCE MANUAL
 S 024-007
 (5)  Remove the recirculation fan:
 (a)  
Remove the electrical connector.

 (b)  
Remove the ground strap.

 (c)  
Remove the clamps.

 (d)  
Remove the sleeves.

 (e)  
Remove the recirculation fan.

 (f)  
Put covers on the duct openings to prevent the entry of unwanted material.


 TASK 21-21-22-404-014
 3. Install The Recirculation Fan (Fig. 401)
_____________________________
 A. References
 (1)  
12-31-01/201, Zone Diagrams

 (2)  
24-22-00/201, Manual Control


 B. Access
 (1)  Location Zone (Ref 12-31-01/201)
 (a)  210, Air-Conditioning Distribution Bay
 C. Procedure
 S 434-015
 (1)  
Remove the duct covers.

 S 424-016

 (2)  
Install the recirculation fan between the mix manifold and the plenum:


 NOTE: Make sure the flow arrow points at the mix manifold.
____
 (a)  
Install the sleeves.

 (b)  
Loosely install the clamps.

 (c)  
Connect the electrical connector.


 NOTE: Turn the recirculation fan until the wire bundle has
____
 no tension.

 (d)  
Tighten the clamps.

 (e)  
Install the ground strap.


 EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. ú

 21-21-22
 ALL  ú ú 02 Page 403 ú Jul 15/90
BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details.
A
737-300/400/500MAINTENANCE MANUAL
 D. Do a Test of the Recirculation Fan
 S 864-022
 (1)  Close these circuit breakers:
 (a)  P6-4 Load Control Circuit Breaker Panel
 1) CABIN AIR RECIRCULATION FAN
 2) RECIRC FAN CONT

 S 864-023
 (2)  Make sure these circuit breakers are closed:
 (a)  P6-4 Load Control Circuit Breaker Panel
 1) R PACK VALVES
 2) L PACK VALVES

 S 864-024
 (3)  Make sure these switches are in the OFF position:
 (a)  P5-10 Air-Conditioning Module
 1) R PACK
 2) L PACK

 S 714-008
 (4)  Do a test of the recirculation fan:
 (a)  
Set the RECIRC FAN switch to the AUTO position. 1) Make sure the recirculation fan operates.

 (b)  
Set the RECIRC FAN switch to the OFF position. 1) Make sure the recirculation fan stops.


 E. Put The Airplane Back To Its Usual Condition
 S 414-010
 (1)  Install these access panels:
 (a)  
Access Panel, Center - Forward Cargo Compartment, Aft Bulkhead

 (b)  
Access Panel, Right - Forward Cargo Compartment, Aft bulkhead


 S 864-028
 (2)  Remove the electrical power from the airplane if it is no longer necessary (Ref 24-22-00/201).
 EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. ú

 21-21-22
 ALL  ú ú 01 Page 404 ú Jul 15/90
BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details.
A
737-300/400/500MAINTENANCE MANUAL
 RECIRCULATION FAN - ADJUSTMENT/TEST
___________________________________
 1.  General_______
 A.  One task is supplied in this procedure. Do an operationl test of the recirculation fan system in that task.
 
中国航空网 www.aero.cn
航空翻译 www.aviation.cn
本文链接地址:737-300 400 500 AMM 飞机维护手册 空调 AIR CONDITIONING 1(32)