21-43-11
ALL ú ú 01 Page 403 ú Jul 15/91
BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details.
A 737-300/400/500MAINTENANCE MANUAL
(c) Make sure the mechanical indicator shows that the outflow valve is in the fully open position.
(6) S 864-017Remove the electrical power if it is not necessary (Ref 24-22-00/201).
(7) S 414-020Install the lining in the forward cargo compartment which you removed to get access to the outflow valve.
EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. ú
21-43-11
ALL ú ú 01 Page 404 ú Jul 15/91
BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details.
A
737-300/400/500MAINTENANCE MANUAL
FORWARD OUTFLOW VALVE - ADJUSTMENT/TEST
_______________________________________
1. General_______
A. This procedure has one task. The task gives instructions for the system test of the forward outflow valve.
B. The forward outflow valve is used to exhaust cooling air from the electronic equipment and forward cargo compartment heating air overboard in flight. The opening and closing of the valve is automatic. The position of the valve is controlled by the position of the aft outflow valve and the operation of the recirculation fan.
C. The forward outflow valve is installed in the left side of the forward cargo compartment.
TASK 21-43-11-705-001
2. Forward Outflow Valve - System Test___________________________________
A. Access
(1) Location Zone
208 Forward Cargo Compartment
220 Aft Cargo Compartment Equipment Bay
B. References
(1)
AMM 24-22-00/201, Manual Control (Apply Power)
(2)
AMM 25-52-73/401, Cargo Compartment Sidewall Lining
C. Prepare for the System Test
S 865-003
(1)
Supply electrical power (AMM 24-22-00/201).
S 865-004
(2)
Make sure that these circuit breakers on the P6-4 panel are closed:
(a)
6B4, AIR CONDITIONING RECIRC FAN CONT
(b)
6B5, AIR CONDITIONING RECIRC FAN ENERGIZED
(c)
6E5, CABIN AIR RECIRCULATION FAN
(d)
6F1, PRESSURIZATION CONTROL AUTOMATIC AC
(e)
6F2, PRESSURIZATION CONTROL AUTOMATIC DC
(f)
6F3, PRESSURIZATION CONTROL STANDBY AC
(g)
6F4, PRESSURIZATION CONTROL STANDBY DC STBY DC
(h)
6F5, PRESSURIZATION CONTROL MANUAL AC
(i)
6F6, PRESSURIZATION CONTROL MANUAL DC
S 015-005
(3) Remove the lining on the forward left sidewall in the forward cargo compartment to get access to the forward outflow valve (AMM 25-52-73/401).
EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. ú
21-43-11
ALL ú ú 01B Page 501 ú Mar 15/99
BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details.
A
737-300/400/500MAINTENANCE MANUAL
D. Do the Forward Outflow Valve System Test
S 865-006
(1)
Put the RECIRC FAN switch on the P5-10 air conditioning module to OFF.
S 015-007
(2)
Get access to the aft outflow valve in the aft end of the aft cargo compartment.
S 015-008
(3)
Disconnect connectors D950 and D952 from the aft outflow valve.
S 485-009
(4)
Connect a jumper wire between connector D952, pins 10 and 14.
S 485-010
(5)
Connect a jumper wire between connector D950, pins 10 and 14.
S 735-011
(6)
Make sure the forward outflow valve closes fully.
S 085-002
(7)
Remove the jumper wire from connector D952, pins 10 and 14.
S 735-012
(8)
Make sure the forward outflow valve remains closed.
S 085-013
(9)
Remove the jumper wire from connector D950, pins 10 and 14.
S 735-014
(10) 中国航空网 www.aero.cn 航空翻译 www.aviation.cn 本文链接地址:737-300 400 500 AMM 飞机维护手册 空调 AIR CONDITIONING 1(121)