 (c)  Make sure that the bag condition indicator on the left water separator is below the red band as shown by the visual indicator on the water separator.
 NOTE: The water separator bag has contamination when the bag
____ condition indicator is in the red band. Remove and replace the water separator bag if the bag condition indicator is in the red band.
 S 715-340
 (4)  Do this check of the flow control and shutoff valve (Left Pack):
 (a)  Disconnect the electrical connector, D392, from the left pack flow control and shutoff valve.
 NOTE: The flow control valve will move to the closed
____
 position.

 (b)  
Make sure that the APU EGT decreases again.

 (c)  
Make sure the left pack flow control and shutoff valve moves towards the closed position.

 (d)  
Connect the electrical connector, D392, to the left pack flow control and shutoff valve.

 (e)  
Make sure the left flow control and shutoff valve moves to the open position.

 (f)  
Let the APU EGT become stable and write down the EGT as Temperature #2.

 (g)  
AIRPLANES WITH GARRETT APU MODELS GTCP85-129C,-129E,-129F; Make sure that the difference between the Temperature #1 APU EGT and the Temperature #2 APU EGT is between the MINIMUM and MAXIMUM curves shown in Figure 502.


 EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. ú

 21-51-00
 ALL  ú ú 01 Page 528 ú Mar 15/98
BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details.
A
737-300/400/500MAINTENANCE MANUAL
 (h)  AIRPLANES WITH GARRETT APU MODELS GTCP85-129H,-129J,-129K; Make sure that the difference between the Temperature #1 APU EGT and the Temperature #2 APU EGT is |40°C of the APU EGT shown in Figure 502 for the HIGH FLOW curve.
 S 715-341
 (5)  Do this check of the supply duct temperature (Left Pack):
 (a)  
When the SUPPLY DUCT temperature is stable, write down the SUPPLY DUCT temperature.

 (b)  
AIRPLANES WITH TEMPERATURE INDICATION IN CELSIUS; Make sure that the SUPPLY DUCT temperature is less than 20°C above the ambient air temperature.


 NOTE: A higher duct temperature is a sign of poor performance
____ of the primary heat exchanger when the pack flow and turbofan operation is normal. The steps which follow can temporarily increase the performance of the primary heat exchanger.
 1)  If the SUPPLY DUCT temperature is more then 20°C above the ambient air temperature, then do these steps: a) Move the L PACK switch to OFF and attach a
 DO-NOT-OPERATE tag. b) Clean the heat exchangers (AMM 21-51-21/701).
 NOTE: If the primary heat exchanger needs to be
____ cleaned, the secondary heat exchanger will also need to be cleaned. The primary and the secondary heat exchangers are cleaned together in AMM 21-51-21/701.
 c) Remove the DO-NOT-OPERATE tag and move the L PACK switch to HIGH. d) Make sure that the SUPPLY DUCT temperature is less than 20°C above the ambient air temperature.
 e)  Replace the primary heat exchanger if the SUPPLY DUCT temperature is more than 20°C above the ambient air temperature.
 EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. ú

 21-51-00
 ALL  ú ú 01 Page 529 ú Mar 15/98
BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details.
A
737-300/400/500MAINTENANCE MANUAL
 (c)  AIRPLANES WITH TEMPERATURE INDICATION IN FAHRENHEIT; Make sure that the SUPPLY DUCT temperature is less than 36°F above the ambient air temperature.
 NOTE: A higher duct temperature is a sign of poor performance
____ of the primary heat exchanger when the pack flow and turbofan operation is normal. The steps which follow can temporarily increase the performance of the primary heat exchanger.
 1)  If the SUPPLY DUCT temperature is more than 36°F above the ambient air temperature, then do these steps: a) Move the L PACK switch to OFF and attach a
 DO-NOT-OPERATE tag. b) Clean the heat exchangers (AMM 21-51-21/701).
 NOTE: If the primary heat exchanger needs to be
____ cleaned, the secondary heat exchanger will also need to be cleaned. The primary and the secondary heat exchangers are cleaned together in AMM 21-51-21/701.
 