E. If the PACK switch is positioned to HIGH but the APU BLEED switch is positioned to OFF, solenoid A will not be energized and the high flow servo will be controlled by solenoid C. The airflow maintained will be lower than that with APU operation.
F. Normal flow operation results from energizing solenoid B (PACK AUTO switch). Energizing solenoid B inactivates the APU/high flow servo and activates the auto flow servo. Airflow operation is controlled in the same manner for both servos.
G. Placing the PACK switch in the OFF position energizes the closing coil of solenoid C, which cuts off air pressure to the actuator and servo valve.
H. A pack valve closed limit switch provides a ground for the pack valve closed relay to drive mix valve full cold after the pack valve closes. The switch is actuated by the valve bellcrank.
3. Primary Heat Exchanger
______________________
A. The primary heat exchanger is the first unit of the air cycle system through which engine bleed air passes to be cooled. The heat exchanger is a counterflow plate-fin type.
B. Hot air enters one plenum chamber from the pneumatic duct at the aft inboard side of the exchanger. It is cooled, then leaves by way of the air cycle machine duct connected to the aft outboard side of the heat exchanger. There is one primary heat exchanger for each air cycle system.
EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. ú
21-51-00
ALL ú ú 03 Page 2 ú Jul 15/91
BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details.
A 737-300/400/500MAINTENANCE MANUAL
AIR CYCLE MACHINE
MUFF SEE B
35`F CONTROL
SEE A TURBINE INLET
OVERHEAT SWITCH
WATER
SEPARATOR SECONDARY HEAT EXCHANGER
35`F TEMPERATURE
SENSOR
PRIMARY HEAT EXCHANGER
TURBOFAN VALVE
35`F CONTROL
VALVE
TURBOFAN
WATER SPRAY VALVE
INJECTOR AIR CYCLE MACHINEFWD MIX VALVE
AIR CYCLE MACHINE COMPRESSOR PACK VALVE TURBINE
A DUAL RAM DOOR
RAM DOOR BLEED FULL OPEN FULL OPEN
RECIRC FAN OFF
AUTO
40 60 OVHT 80
PSI 0 100 TEST
L PACK R PACK
ISOLATION
OFF VALVE OFF
CLOSE
AUTO AUTO HIGH HIGH
AUTO
WING WING
COMPRESSOR
PACKPACK OPENANTI ANTITRIP OFFTRIP OFFICE
ICE WING-BODY
DISCHARGE
WING-BODY
TRIP
OVERHEATOVERHEAT
OVERHEAT
BLEED BLEED
SWITCH
TRIP OFF TRIP OFF
COMPRESSOR
RESET
SIGHT GAGE OFF OFF
ON ON
DRAIN PLUG
1 APU 2
TURBINE BLEED
AUTOOFF SCHED STANDBY MANUAL
FWD
FAIL DESCENT
P5-10 AIR CONDITIONING MODULE
B
Air Cycle System Component Location
Figure 1