B. Procedure
S 014-001
(1)
Remove the aft bulkhead panel (right) in the aft cargo compartment to get access to the safety relief valves.
S 024-017
(2)
If you cannot get access to the safety relief valve from the aft cargo compartment, remove the cabin pressurization outflow valve (AMM 21-31-11/401).
S 034-002
(3)
Loosen the clamp at the bottom of the safety relief valve.
S 034-003
(4)
Move the clamp down to the pedestal.
(5)
Remove the safety relief valve.
(6)
Remove the gasket.
S 024-004
S 034-015
TASK 21-32-21-404-006
3. Safety Relief Valve Installation________________________________
A. Consumable Materials
(1) Grease - Dow Corning DC55
EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. ú
21-32-21
ALL ú ú 02 Page 401 ú Mar 12/00
BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details.
A
737-300/400/500MAINTENANCE MANUAL
SAFETY RELIEF VALVE (2 LOCATIONS)
SEEA
AFT BULKHEAD
PANEL (REF)
EQUALIZATION
CABIN PRESSURIZATION VALVE (REF)
OUTFLOW VALVE
(REF) AFT CARGO
CAMPARTMENT FILTER AND
(REF) COVER
SAFETY
RELIEF
VALVE
GASKET
CLAMP
PEDESTAL
AMBIENT SENSE TUBE
SAFETY RELIEF VALVE
FWD INBD
A
Safety Relief Valve Installation Figure 401
EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. ú
21-32-21
ALL ú ú 01 Page 402 ú Jul 15/91
BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details.
A
737-300/400/500MAINTENANCE MANUAL
B. References
(1) AMM 21-32-21/501, Safety Relief Valve
C. Access
(1) Location Zone
220 Aft Cargo Compartment Equipment Bay
D. Procedure
S 394-007
(1) Apply Dow Corning DC55 grease to each side of the gasket.
S 434-008
CAUTION: MAKE SURE YOU DO NOT CAUSE THE AMBIENT SENSE PORT TO BECOME
_______ BLOCKED WHEN YOU INSTALL THE GASKET ON THE PEDESTAL. THE SAFETY RELIEF VALVE WILL NOT OPERATE CORRECTLY IF THE AMBIENT SENSE PORT IS BLOCKED.
(2)
Install the gasket on the pedestal.
S 214-009
(3)
Make sure there is no blockage in the ambient sense port and the safety relief valve.
S 424-010
CAUTION: BE CAREFUL WHEN YOU INSTALL THE SAFETY RELIEF VALVE ON THE
_______ PEDESTAL. DAMAGE COULD OCCUR TO THE AMBIENT SENSE TUBE.
(4)
Put the safety relief valve in its position on the pedestal.
S 434-011
(5)
Put the clamp around the top of the pedestal and the bottom of the safety relief valve.
(6)
Tighten the clamp.
(7)
Do a test of the safety relief valve (AMM 21-32-21/501).
S 434-012
S 714-013
NOTE: You do not have to do the test if a new or serviceable valve
____
is installed.
EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. ú
21-32-21
ALL ú ú 02 Page 403 ú Mar 12/00
BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details.
A 737-300/400/500MAINTENANCE MANUAL
(8) S 424-018If the cabin pressurization outflow valve was removed, install the cabin pressurization outflow valve (AMM 21-31-11/401).
(9) S 414-014Install the aft bulkhead panel (right) which you removed to get access to the safety relief valves.