Stowages - Component Location Figure 001
R EFF : 001-049, 101-105, 25-27-00 Page 2 May 01/05
CES
R R Stowages - Component Location Figure 001A
R EFF : 051-099, 25-27-00 Page 3 May 01/05
CES
**ON A/C 151-199,
A. Stowages R (Ref. Fig. 001B) -------------------------------------------------------------------------------FIN | FUNCTIONAL DESIGNATION | PANEL|ZONE|ACCESS | ATA
| | | | DOOR | REF. -------------------------------------------------------------------------------6579MM STOWAGE LH 231 25-27-44 6580MM STOWAGE RH 232 25-27-44 6601MM DOGHOUSE LH 231 25-27-46 6600MM DOGHOUSE RH 232 25-27-46 6601MM DOGHOUSE LH 261 25-27-46 6600MM DOGHOUSE RH 262 25-27-46 ------EMERGENCY EQUIPMENT STOWAGE 261 25-27-15
**ON A/C 201-210,
A. Stowages R (Ref. Fig. 001C) -------------------------------------------------------------------------------FIN | FUNCTIONAL DESIGNATION | PANEL|ZONE|ACCESS | ATA
| | | | DOOR | REF. -------------------------------------------------------------------------------6579MM STOWAGE LH 231 25-27-44 6580MM STOWAGE RH 232 25-27-44 6601MM DOGHOUSE LH 231 25-27-46 6600MM DOGHOUSE RH 232 25-27-46 ------EMERGENCY EQUIPMENT STOWAGE 261 25-27-15
R Stowages - Component Location Figure 001B
R EFF : 151-199, 25-27-00 Page 5 May 01/05
CES
R Stowages - Component Location Figure 001C
R EFF : 201-210, 25-27-00 Page 6 May 01/05
CES
**ON A/C 301-399,
B. Heated Floor Panels
(Ref. Fig. 002)
-------------------------------------------------------------------------------FIN | FUNCTIONAL DESIGNATION | PANEL|ZONE|ACCESS | ATA | | | | DOOR | REF.
-------------------------------------------------------------------------------4DS CONTROL UNIT-DOOR AREA HEATING 132 132JW 25-27-34 5DS FLOOR PANEL-HEATED, DOOR AREA 241 25-27-51 6DS FLOOR PANEL-HEATED, DOOR AREA 242 25-27-51 14DS CONTROL UNIT-DOOR AREA HEATING 152 152FW 25-27-34 15DS FLOOR PANEL-HEATED, DOOR AREA 251 25-27-51 16DS FLOOR PANEL-HEATED, DOOR AREA 252 25-27-51
**ON A/C ALL
3. System Description__________________
A. Stowages
The stowage basic structure is made from sandwich panels. The sandwich panels are covered with Glassfibre Reinforced Plastic (GFRP) plates. Extrusions are bonded and/or riveted to the panels. Bonded edge profiles, stainless-steel kick strips and rub strips are installed to protect the stowages where applicable. The stowages are attached to the seat tracks with fittings and to the aircraft structure with tie-rods.
**ON A/C 301-399,
B. Heated Floor Panel System
(Ref. Fig. 003)
(1)
General The heated floor panels increase the temperature in areas of the cabin which are much colder than other areas in the cabin.
(2)
System Architecture
The heated floor panel system has:
-Heated floor panels
-Control units.
R R Stowages - Component Location Figure 001D
R EFF : 301-399, 25-27-00 Page 8 May 01/05
CES
INTENTIONALLY BLANK
Heated Floor Panel System - Emergency Exits - Component Location Figure 002 (SHEET 1)
EFF : 301-399, 25-27-00Page 10 May 01/05 R CES
Heated Floor Panel System - Emergency Exits - Component Location Figure 002 (SHEET 2)
EFF : 301-399, 25-27-00Page 11 May 01/05 R CES
Heated Floor Panel System - Schematic (Typical) Figure 003
R EFF : CES 301-399, 25-27-00 Page 12 May 01/05
(3) Description
The heated floor panel system operates when:
-
The circuit brakers of the system are closed.
-
The galley supply system operates (Ref. 24-56-00). The heated floor panels:
-Have sensors which measure constantly the temperature of the panels.
-Are connected to the control units.
-Give data of the measured temperature to the control units. The control units:
-Supplies electrical power to the heated floor panels if the temperature is less than a given temperature.
-Removes the electrical power supply from the heated floor panels if the temperature is more than a given temperature.
4. Power Supply
____________
A. Heated Floor Panel System The heated floor panels are supplied with 115 VAC from the busbars 212XP and 214XP through the circuit breakers:
中国航空网 www.aero.cn
航空翻译 www.aviation.cn
本文链接地址:A320飞机维护手册 AMM EQUIPMENT/FURNISHINGS 设备2(81)