_______ DEPRESSURIZED. A PRESSURIZED SYSTEM CAN CAUSE INJURY TO PERSONS WHEN THEY DO WORK ON IT.
(c)
Push up the insulation (10), loosen the nut (11) and disconnect the potable water pipe (12).
(d)
Push up the insulation and remove the clamps (14) from the hose (15).
(e)
Disconnect the drain hose (13) from the hose (15).
(f)
Put blanking plugs on the disconnected line ends.
(3)
Remove the Air Supply Connections (Ref. Fig. 402/TASK 25-31-41-991-014)
(a)
Release the clamps (5) and disconnect the exhaust air hose (6) from the hose (4).
(b)
Release the clamp (8) and disconnect the fresh air supply hose
(9) from the hose (7).
(c)
Put blanking plugs on the disconnected line ends.
(4)
Remove the Upper Attachments (Ref. Fig. 403/TASK 25-31-41-991-018)
(a)
Remove the screws (2) and the pelmet (1).
(b)
Release the quick-release fastners (3) and remove the panel (10).
(c)
Release the clamp (9).
(d)
Remove the fresh air hose (8) from the fresh air outlet (7).
(e)
Remove the quick-release pins (5) and disconnect the tie rods (4).
(f)
Remove the tie rods (4) from the brackets (6) and the aircraft structure.
(5)
Remove the Lower Attachments (Ref. Fig. 404/TASK 25-31-41-991-019)
(a)
Remove the screws (1) and the rub strips (2).
(b)
Remove the screws (4) and the covers (3).
(c)
Remove the screws (6) and the covers (5).
(d)
Remove the bolts (8), the washers (9) and the plates (11).
(e)
Remove the bolts (7) and the washers (10).
(f)
Remove the eccentric plug (13) and the eccentric bush (12).
(g)
Remove the galley unit. WARNING : SUPPORT THE UNIT/ASSEMBLY OR IT WILL FALL AND BECOME
_______
(h)
Remove the shims (14). NOTE : Identify the position and number of the shims for the
Electrical Connections Figure 401/TASK 25-31-41-991-038- 12 (SHEET 1)
R EFF : 001-049, 101-105, 25-31-41 Page 410 May 01/05
CES
Electrical Connections Figure 401/TASK 25-31-41-991-038- 22 (SHEET 2)
R EFF : 001-049, 101-105, 25-31-41 Page 411 May 01/05
CES
R R Electrical Connections - G1 Figure 401A/TASK 25-31-41-991-038-C12 (SHEET 1)
R EFF : 051-099, 25-31-41 Page 412 May 01/05
CES
R R Electrical Connections - G1 Figure 401A/TASK 25-31-41-991-038-C22 (SHEET 2)
R EFF : 051-099, 25-31-41 Page 413 May 01/05
CES
Electrical Connections - G1 Figure 401B/TASK 25-31-41-991-038-A12 (SHEET 1)
R EFF : 106-149, 201-299, 25-31-41 Page 414 May 01/05
CES
Electrical Connections - G1 Figure 401B/TASK 25-31-41-991-038-A22 (SHEET 2)
R EFF : 106-149, 201-299, 25-31-41 Page 415 May 01/05
CES
R Electrical Connections - G1 Figure 401C/TASK 25-31-41-991-038-B12 (SHEET 1)
EFF : 151-199, 25-31-41 Page 416 May 01/05
CES
R Electrical Connections - G1 Figure 401C/TASK 25-31-41-991-038-B22 (SHEET 2)
R EFF : 151-199, 25-31-41 Page 417 May 01/05
CES
Galley connections - G1 Figure 402/TASK 25-31-41-991-014
R EFF : 001-049, 101-105, 25-31-41 Page 418 May 01/05
CES
R R Galley Connections - G1 Figure 402A/TASK 25-31-41-991-014-C
R EFF : 051-099, 25-31-41 Page 419 May 01/05
CES
Galley Connections - G1 Figure 402B/TASK 25-31-41-991-014-A
R EFF : 106-149, 201-299, 25-31-41 Page 420 May 01/05
CES
R Galley Supply Connections - G1 Figure 402C/TASK 25-31-41-991-014-B
R EFF : 151-199, 25-31-41 Page 421 May 01/05
CES