(j)
Let the window panes dry.
(k)
Do a check and make sure that the window panes are dry and polish them with a clean, lintfree cloth.
NOTE : You must wear cotton gloves when you touch the window
____
panes.
(10)
Install the inner pane (11) and the decor cover (12) and make sure that it engages correctly.
(11)
Put the support assy (3) in position and install it with the washers
(2) and the screws (1) to the upper sidewall panel assy (6).
R **ON A/C 151-199, 401-499,
Subtask 25-23-47-420-051-A
A. Installation of the Upper Sidewall Panel Assy 241FW (242FW) (6) (Ref. Fig. 403A/TASK 25-23-47-991-002-A)
(1) Put the upper sidewall panel assy (6) in position on the brackets (9) and on the yo-yo rolls and push it down.
NOTE : Make sure that the upper sidewall panel assy (6) engages
____
correctly.
(2)
Put the washers (5) in position and install the screws (4).
(3)
Put the lining strip(s) (7), (8) in position on the the lower end of the sidewall panel assy (6) and the adjacent panel and push it up.
NOTE : Make sure that the lining strip(s) (7), (8) engage correctly.
____
(4) Install the wall-mounted emergency markers (Ref. TASK 33-51-13-400-001)
R **ON A/C 001-049, 051-099, 101-149, 151-199, 201-299, 401-499,
5. Close-up
________
Subtask 25-23-47-865-053
A. Remove the safety clip(s) and the tag(s) and close this(these) circuit breaker(s): 1WL, 2WL, 3WL.
Subtask 25-23-47-942-050
B. Remove the warning notices from the panels 25VU and 120RH.
Subtask 25-23-47-410-061
C. Close Access
(1)
Install the emergency exit hatches (Ref. TASK 52-21-11-400-001).
(2)
Install the passenger seat if removed (Ref. TASK 25-21-41-400-001).
R EFF : 001-049, 051-099, 101-149, 151-199, 25-23-47Page 420 201-299, 401-499, Config-1 Aug 01/05
CES Subtask 25-23-47-410-050
D. Close Access
(1)
Install the emergency exit sign 42WL (43WL) (Ref. TASK 33-51-16-400-001)
(2)
Install the emergency exit hatch (Ref. TASK 52-21-11-400-001)
(3)
Install the passenger seat, if removed (Ref. TASK 25-21-41-400-001)
(4)
Install the wall-mounted emergency exit-markers (Ref. TASK 33-51-13-400-001)
Subtask 25-23-47-862-062
E. De-energize the ground service network (Ref. TASK 24-42-00-862-001)
R EFF : 001-049, 051-099, 101-149, 151-199, 25-23-47Page 421 201-299, 401-499, Config-1 Aug 01/05
CES
LINING - EMERGENCY EXIT - REMOVAL/INSTALLATION
______________________________________________
TASK 25-23-47-000-004
Removal of the Door Frame Linings of the LH FWD Emergency Exit Door, zone 231
1. Reason for the Job
__________________
Self Explanatory
2. Job Set-up Information
______________________
A. Fixtures, Tools, Test and Support Equipment
-------------------------------------------------------------------------------REFERENCE QTY DESIGNATION
-------------------------------------------------------------------------------
No specific blanking plugs
No specific circuit breaker(s) safety clip(s)
B. Referenced Information
-------------------------------------------------------------------------------REFERENCE DESIGNATION -------------------------------------------------------------------------------
24-42-00-861-001 Energize the Ground Service Network from the External
Power 25-62-49-000-001 Inflation Reservoir, Escape-Slide - Removal 33-51-11-000-001 Removal of the Cabin Emergency Lights 33-51-13-000-001 Removal of the Cabin Wall-Mounted
Emergency-Exit-Markers 33-51-16-000-001 Removal of the Emergency Exit Sign 52-22-00-010-001 Opening of the Emergency Exit Doors from the
Passenger Compartment 25-23-47-991-008 Fig. 401
3. Job Set-up
__________
Subtask 25-23-47-861-072
A. Aircraft Maintenance Configuration
(1) Energize the ground service network
(Ref. TASK 24-42-00-861-001)
Subtask 25-23-47-010-076
B. Get Access
(1)
Put the access platform in position on the related emergency exit door.
(2)
Open the related emergency exit door (Ref. TASK 52-22-00-010-001).
(3)
Remove the emergency exit sign 47WL (Ref. TASK 33-51-16-000-001)
中国航空网 www.aero.cn
航空翻译 www.aviation.cn
本文链接地址:A320飞机维护手册 AMM EQUIPMENT/FURNISHINGS 设备2(40)