EFF : ALL
25-28-42Page 456
May 01/04
R NOTE : It is recommended that two persons do this procedure.____
R (1) Make sure that the parts retained from the removed component are
R clean and in the correct condition.
R WARNING : OBEY THE MANUFACTURER'S INSTRUCTIONS WHEN YOU USE_______
R THIS/THESE MATERIAL/S.
R USE PROTECTIVE CLOTHING, RUBBER GLOVES, GOGGLES AND A MASK.
R (2) Installation of the self-adhesive Film BONDING AND ADHESIVE COMPOUNDS
R (Material No. 08-082) (2) to the new NTF (1) (GFRP attached):
R (a) Clean the component interface and/or the adjacent area.
R Use CLEANING AGENTS (Material No. 11-004).
R (b) Do a visual inspection of the component interface and/or the
R adjacent area.
R (c) Unwind 100 mm (3.9370 in.) of the new self-adhesive film (2) from
R the roll and remove the protective paper.
R (d) Align the self-adhesive film (2) with the NTF (1) and install it
R with a soft cotton cloth MISCELLANEOUS (Material No. 19-003) and
R light pressure of your hand. Work from the middle of the of the
R self-adhesive film (2) towards the sides.
R (e) With a ROLLER - RUBBER press down the self-adhesive film (2) onto
R the NTF (1).
R NOTE : Move the rubber roller backwards and forwards and around____
R the edges for a better bond.
R (f) Do the steps (2)(c) thru (e) until you have installed all of the
R NTF (1) with the self-adhesive film (2).
EFF : ALL
25-28-42Page 457
R Subtask 25-28-42-560-056
R C. Installation of the Self-Adhesive Film to the "Conventional" NTF and the
R GFRP (Glass-Fiber-Reinforced-Plastic).
R (Ref. Fig. 404/TASK 25-28-42-991-012)
R WARNING : MAKE SURE THAT THERE IS A GOOD FLOW OF AIR THROUGH THE WORK_______
R AREA WHEN YOU USE SPECIAL MATERIALS.
R IF YOU GET ONE OF THESE MATERIALS ON YOUR SKIN, IN YOUR MOUTH
R OR IN YOUR EYES :
R -FLUSH IT AWAY WITH A FLOW OF CLEAN WATER FOR BETWEEN 10 AND 15
R MINUTES.
R -GET IMMEDIATE MEDICAL AID IF IRRITATION OCCURS.
R DO NOT BREATHE THE FUMES FROM THE MATERIAL.
R DO NOT SMOKE WHEN YOU USE THE MATERIAL.
R DO NOT USE THE MATERIAL NEAR A FLAME, SPARKS OR SOURCES OF
R HEAT.
R THESE MATERIALS ARE DANGEROUS : THEY ARE POISONOUS, FLAMMABLE
R AND SKIN IRRITANTS.
R NOTE : Follow this procedure only, when the NTF (1) is not attached to____
R the GFRP (5). (Conventional NTF floor covering)
R NOTE : It is recommended that two persons do this procedure.____
R (1) Make sure that the parts retained from the removed component are
R clean and in the correct condition.
R (2) Installation of the self-adhesive Film BONDING AND ADHESIVE COMPOUNDS
R (Material No. 08-082) (2) to the new NTF (1):
R WARNING : OBEY THE MANUFACTURER'S INSTRUCTIONS WHEN YOU USE_______
R THIS/THESE MATERIAL/S.
R USE PROTECTIVE CLOTHING, RUBBER GLOVES, GOGGLES AND A MASK.