REFERENCE DESIGNATION
-------------------------------------------------------------------------------
52-30-00-860-002 Close the FWD or AFT Cargo-Compartment Door with the Yellow Electric Pump 52-30-00-860-008 Close the Bulk Cargo-Compartment Door
**ON A/C 001-049, 051-099, 101-101, 106-149, 221-221, 224-224, 228-228,
53-42-17-991-001 Fig. 401
**ON A/C 102-105,
53-42-17-991-001-A Fig. 401A
**ON A/C 151-199,
53-42-17-991-001-C Fig. 401B
**ON A/C 201-220, 222-223, 225-227, 229-299,
53-42-17-991-001-B Fig. 401C
**ON A/C 301-399,
53-42-17-991-001-D Fig. 401D R **ON A/C 401-499,
R 53-42-17-991-001-E Fig. 401E
EFF : ALL
53-42-17Page 413
**ON A/C ALL
3. Job Set-up
__________
Subtask 53-42-17-860-050
A. Aircraft Maintenance Configuration
(1) Make sure that the aircraft is in the same configuration as for the removal task.
4. Procedure
_________
**ON A/C 001-049, 051-099, 101-101, 106-149, 221-221, 224-224, 228-228,
(Ref. Fig. 401/TASK 53-42-17-991-001)
**ON A/C 102-105,
(Ref. Fig. 401A/TASK 53-42-17-991-001-A)
**ON A/C 151-199,
(Ref. Fig. 401B/TASK 53-42-17-991-001-C)
**ON A/C 201-220, 222-223, 225-227, 229-299,
(Ref. Fig. 401C/TASK 53-42-17-991-001-B)
**ON A/C 301-399,
(Ref. Fig. 401D/TASK 53-42-17-991-001-D) R **ON A/C 401-499,
R (Ref. Fig. 401E/TASK 53-42-17-991-001-E)
EFF : ALL
53-42-17Page 414
**ON A/C ALL
Subtask 53-42-17-916-050
A. Preparation for Installation
(1) Remove the old sealant from the floor panels with a nonmetallic scraper.
WARNING : USE SOLVENTS/CLEANING AGENTS, SEALANTS AND OTHER SPECIAL
_______ MATERIALS ONLY WITH A GOOD SUPPLY OF AIR. OBEY THE MANUFACTURERS INSTRUCTIONS. PUT ON PROTECTIVE CLOTHING. DO NOT GET THEM IN YOUR MOUTH. DO NOT SMOKE. DO NOT BREATHE THE GAS. THESE MATERIALS ARE POISONOUS, FLAMMABLE AND SKIN IRRITANT. GET MEDICAL HELP IF YOUR SKIN OR EYES BECOME IRRITATED.
WARNING : OBEY THE MANUFACTURER'S INSTRUCTIONS WHEN YOU USE THE
_______
SPECIAL MATERIAL.
THIS MATERIAL IS DANGEROUS.
(2)
Clean the component interface and the adjacent area with CLEANING AGENTS (Material No. 11-003) and a lint free cloth.
(3)
Make sure that the parts retained from the removed component are clean and in the correct condition.
(4)
Do an inspection of the component interface and/or the adjacent area.
**ON A/C 001-049, 051-099, 101-101, 106-149, 221-221, 224-224, 228-228,
Subtask 53-42-17-420-050
B. Installation of the Floor Panels:
(1)
Make sure that the work area is clean and clear of tool(s) and other items.
(2)
Put the floor panels (1) and the seals (3) and (7) in position.
(3)
Apply SPECIAL MATERIALS (Material No. 05-002) to the screws (2), (8) and (11).
(4)
Install the screws (2) and TORQUE to 0.42 m.daN (37.16 lbf.in).
(5)
Install the cord (4) FIBER GLASS CORD 1.1MM DIA. (DAN107-1) in the gap between the floor panels (1).
NOTE : Make a loop at the end of the cord, this will help the next
____
removal procedure.
(6)
Apply SEALANTS (Material No. 09-005) in the gap between the floor panels (1) and the cutouts of the tiedown positions.