-cracks.
NOTE : If necessary, refer to the ASRM (Ref. ASRM 53-41-11-101) for
____
the correct repair procedure.
EFF : ALL
53-41-00Page 669
May 01/04
R
CES
Skin Cutout of the VHF 3 Antenna Figure 616/TASK 53-41-00-991-019
R EFF : CES ALL 53-41-00 Page 670 May 01/04
5. Close-up
________
Subtask 53-41-00-410-093
A. Close Access
(1)
Make sure that the work area is clean and clear of tool(s) and other items.
(2)
Install the VHF 3 antenna (Ref. TASK 23-12-11-400-002).
(3)
Remove the ground support and maintenance equipment, the special and standard tools and all other items.
EFF : ALL
53-41-00Page 671
May 01/04
R
CES
TASK 53-41-00-210-020
Detailed Visual Inspection of Skin in Circumferential Splice and Stringer
Coupling Areas at FR64, from STGR10, LH/RH, to Crown Center Line
1.
Reason for the Job
__________________
Refer to the MPD TASK: 534113-01
2.
Job Set-up Information
______________________
A. Fixtures, Tools, Test and Support Equipment
-------------------------------------------------------------------------------
REFERENCE QTY DESIGNATION
-------------------------------------------------------------------------------
No specific lint-free cloth
No specific access platform 6.0 m (19 ft. 8 in.)
B. Consumable Materials
-------------------------------------------------------------------------------
REFERENCE DESIGNATION
-------------------------------------------------------------------------------
R Material No. 11-003 USA ASTM D 740 METHYL-ETHYL-KETONE (Ref. 20-31-00)
C. Referenced Information
-------------------------------------------------------------------------------
REFERENCE DESIGNATION
-------------------------------------------------------------------------------
ASRM 53-41-11-101 (for corrective action)
53-41-00-991-020 Fig. 617
EFF : ALL
53-41-00Page 672
3. Job Set-up
__________
Subtask 53-41-00-941-059
A. Get Access
(1) Put the access platform in position adjacent to FR64. WARNING : OBEY THE MANUFACTURER'S INSTRUCTIONS WHEN YOU USE THE
_______
SPECIAL MATERIAL.
THIS MATERIAL IS DANGEROUS.
WARNING : USE SOLVENTS/CLEANING AGENTS, SEALANTS AND OTHER SPECIAL
_______ MATERIALS ONLY WITH A GOOD SUPPLY OF AIR. OBEY THE MANUFACTURERS INSTRUCTIONS. PUT ON PROTECTIVE CLOTHING. DO NOT GET THEM IN YOUR MOUTH. DO NOT SMOKE. DO NOT BREATHE THE GAS. THESE MATERIALS ARE POISONOUS, FLAMMABLE AND SKIN IRRITANT. GET MEDICAL HELP IF YOUR SKIN OR EYES BECOME IRRITATED.
(2) Clean the inspection area with CLEANING AGENTS (Material No. 11-003) and a lint-free cloth.
4. Procedure
_________
(Ref. Fig. 617/TASK 53-41-00-991-020) Subtask 53-41-00-210-076
A. Inspection
(1) Examine the circumferential skin splice FR64 between STGR10 LH and STGR10 RH for cracks.
NOTE : If necessary, refer to the ASRM (Ref. ASRM 53-41-11-101) for
____
the correct repair procedure.
5. Close-up
________ Subtask 53-41-00-942-076
A. Close Access
(1)
Make sure that the work area is clean and clear of tool(s) and other items.
(2)
Remove the access platform(s).
(3)
Remove the ground support and maintenance equipment, the special and standard tools and all other items.
EFF : ALL
53-41-00Page 673
May 01/04
R
CES
Circumferential Skin Splice FR64 Figure 617/TASK 53-41-00-991-020
R EFF : CES ALL 53-41-00 Page 674 May 01/04
TASK 53-41-00-210-021
Detailed Visual Inspection of AFT Passenger/Crew Door Cutout Lower Corners including Skin and Doubler underneath the Scuff Plate, LH/RH
1.
Reason for the Job
__________________
Refer to the MPD TASK: 534133-01
2.
Job Set-up Information
______________________
A. Referenced Information
-------------------------------------------------------------------------------REFERENCE DESIGNATION -------------------------------------------------------------------------------
53-45-15-000-001 Removal of the Scuff Plates at the AFT Passenger/Crew Doors 53-45-15-400-001 Installation of the Scuff Plates at the AFT