C. Referenced Information
-------------------------------------------------------------------------------REFERENCE DESIGNATION -------------------------------------------------------------------------------
25-33-41-000-002 Removal of the AFT Galley Unit (6481MM or 6483MM) 25-33-41-400-002 Installation of the AFT Galley Unit (6481MM or
6483MM) 25-43-43-000-001 Removal of the Lavatory F 25-43-43-400-001 Installation of the Lavatory F 25-80-00-000-001 Removal of the Insulation Blankets 25-80-00-400-001 Installation of the Insulation Blankets 51-75-13-916-001 Repair to a layer of Moisture-Removing Oil ASRM 535116000 (for corrective action) 53-51-00-991-009 Fig. 607
3. Job Set-up
__________
Subtask 53-51-00-010-063
A. Get Access
(1)
Remove the lavatory F (Ref. TASK 25-43-43-000-001).
(2)
Remove the aft galley (Ref. TASK 25-33-41-000-002).
(3)
Remove the insulation blankets from the rear pressure bulkhead (Ref. TASK 25-80-00-000-001).
NOTE : Identify the insulation blankets for installation.
____
Subtask 53-51-00-110-056
B. Carefully clean the inspection area with CLEANING AGENTS (Material No. 11-004) and a lint-free cloth.
WARNING : OBEY THE MANUFACTURER'S INSTRUCTIONS WHEN YOU USE THE SPECIAL
_______
MATERIAL.
THIS MATERIAL IS DANGEROUS.
EFF : ALL
53-51-00Page 627
WARNING : USE SOLVENTS/CLEANING AGENTS, SEALANTS AND OTHER SPECIAL
_______ MATERIALS ONLY WITH A GOOD SUPPLY OF AIR. OBEY THE MANUFACTURERS INSTRUCTIONS. PUT ON PROTECTIVE CLOTHING. DO NOT GET THEM IN YOUR MOUTH. DO NOT SMOKE. DO NOT BREATHE THE GAS. THESE MATERIALS ARE POISONOUS, FLAMMABLE AND SKIN IRRITANT. GET MEDICAL HELP IF YOUR SKIN OR EYES BECOME IRRITATED.
4. Procedure
_________
(Ref. Fig. 607/TASK 53-51-00-991-009) Subtask 53-51-00-210-061
A. Inspection:
(1) Examine the forward face of the rear pressure bulkhead for corrosion. NOTE : If necessary, refer to the ASRM (Ref. ASRM 535116000) for the
____
correct repair procedure.
5. Close-up
________ Subtask 53-51-00-916-053
A. Apply STORAGE PRESERVATION (Material No. 15-005) and STORAGE PRESERVATION (Material No. 15-006) to the inspection area (Ref. TASK 51-75-13-916-001).
Subtask 53-51-00-410-062
B. Close Access
(1)
Make sure that the work area is clean and clear of tool(s) and other items.
(2)
Install the insulation blankets to the rear pressure bulkhead (Ref. TASK 25-80-00-400-001).
(3)
Install the aft galley (Ref. TASK 25-33-41-400-002).
(4)
Install the lavatory F (Ref. TASK 25-43-43-400-001).
(5)
Remove the ground support and maintenance equipment, the special and standard tools and all other items.
EFF : ALL
53-51-00Page 628
Rear Pressure-Bulkhead Forward-Face above the Cabin Floor
Figure 607/TASK 53-51-00-991-009
EFF : ALL
53-51-00Page 629
Feb 01/98
CES
TASK 53-51-00-210-009
Detailed Visual Inspection of Tail Cone Attachment Fittings at FR77 and FR78
1. Reason for the Job
__________________
Refer to the MPD TASK: 535151-01
2. Job Set-up Information
______________________
A. Fixtures, Tools, Test and Support Equipment
-------------------------------------------------------------------------------REFERENCE QTY DESIGNATION -------------------------------------------------------------------------------
No specific lint-free cloth
No specific nonmetallic scraper
No specific warning notice
No specific access platform 3.5 m (11 ft. 6 in.)
B. Consumable Materials
-------------------------------------------------------------------------------REFERENCE DESIGNATION -------------------------------------------------------------------------------
Material No. 11-004 USA MIL-T-81533
1.1.1TRICHLOROETHANE (METHYL CHLOROFORM)
(Ref. 20-31-00)
Material No. 15-007 AIB TN 10138 TYPE II GRADE 1 CORROSION PREVENTIVE TEMPORARY PROTECTIVE COMPOUND (Ref. 20-31-00) 中国航空网 www.aero.cn 航空翻译 www.aviation.cn 本文链接地址:A320飞机维护手册 AMM FUSELAGE 机身3(105)