The parameter number shows on thebottom of the display (scratchpad).
-On the AIDS REPORT LIMITS page addsfollowing indication:OLD LIMIT, NEW LIMIT, VALIDITY, REASON, VALIDATE and RETURN TO DEFAULT.
-
The new limit value shows on thebottom of the display (scratchpad).
-
The new limit value shows under theNEW LIMIT indication.
-
The new validity value shows on thebottom of the display (scratchpad).
-
The reason shows on the bottom of thedisplay (scratchpad).
R 1EFF : 106-149, 211-299, 301-399, 401-499, 1 31-36-00Page 249 1 1 Aug 01/05 1 1 1CES 1
 -------------------------------------------------------------------------------
ACTION RESULT -------------------------------------------------------------------------------NOTE : The REASON indication you can enter optional to inform the operator
____ about the reason of the limit change.
 -Push the line key adjacent to *  - The message VALIDATE OK shows. VALIDATE indication to save the new limit values.
 On the center pedestal:
 -The printer makes a printout of the revised limit values.
 NOTE : If you push the line key adjacent to RETURN TO DEFAULT * the default
____
 value is used (GSE). On the MCDU: 
-Push the line key adjacent to < RETURN indication. 
Subtask 31-36-00-740-078
 D. Programmable Report CountersOn the MCDU display:
-The AIDS DMU PROGRAMMING page comesinto view.
 -------------------------------------------------------------------------------ACTION RESULT -------------------------------------------------------------------------------
On the MCDU:  On the MCDU display: 
 - Push the line key adjacent to <  - The AIDS REPORT COUNTERS page comes 
 REPORT INT COUNTERS indication.  into view. 
 - Push the line key adjacent to the  - The related AIDS REPORT X COUNTERS 
 related Report Number indication  page comes into view. 
 (e.g. < REPORT 01). 
 - Set the selected report counter 
 value to its corresponding limit. 
 - Push the line key adjacent to <  - The AIDS DMU PROGRAMMING page comes 
 RETURN indication.  into view. 
R 1EFF : 106-149, 211-299, 301-399, 401-499, 1 31-36-00Page 250 1 1 Aug 01/05 1 1 1CES 1 Subtask 31-36-00-740-079-A
 E. Statistic Counters NOTE : On the AIDS:STATISTIC CNTR menu you can update the hours and the
____ cycles of the APU and the Engines (ENG-1 FLT HRS, ENG-2 FLT HRS, APU FLT HRS, ENG-1 CYCLES, ENG-2 CYCLES and APU CYCLES).
 (1)
 To update the APU hours and cycles do the procedure (Ref. AMM TASK 31-36-00-740-013) 'To update the APU hours and cycles into the FDIMU (10TV)'.
 (2)
 To update the Engine hours and cycles do the procedure (Ref. AMM TASK 31-36-00-740-014) 'To update the Engine hours and cycles into the FDIMU (10TV)'.
 Subtask 31-36-00-740-080
 F. Dump Disk Status Information
 -------------------------------------------------------------------------------ACTION RESULT -------------------------------------------------------------------------------
On the MCDU: 
-
Push the MCDU MENU mode key.
-
Push the line key adjacent to the < AIDS indication.
 -
Push the line key adjacent to the < SPECIAL FUNCT/REPROGRAMMING indication.
 -
Push the line key adjacent to the DUMP STATUS > indication.
 -Enter the password with alphnumeric keys into the scratchpad.
 -
Push the line key adjacent to the < ENTER PASSWORD indication.
-
Push the line key adjacent to the DUMP STATUS > indication.
On the MCDU display:
-
The MCDU MENU page shows.
-
The AIDS page shows.
-
The AIDS:SPECIAL FUNC/REPROG pageshows.
-
The AIDS ACCESS CONTROL page shows.
-An asterisk for each enteredcharacter shows on the scratchpad.
-
The AIDS:SPECIAL FUNC/REPROG pageshows.
-
The AIDS: DUMP DISK STATUS pageshows.
R 1EFF : 106-149, 211-299, 301-399, 401-499, 1 31-36-00Page 251 1 1 Aug 01/05 1 1 1CES 1
 -------------------------------------------------------------------------------
ACTION ------------------------------------- RESULT------------------------------------------ 
 