R 1EFF : 151-199, 201-210, 1 31-36-00Page 243 1 1 Aug 01/03 1 1 1CES 1R Subtask 31-36-00-740-064-A
R C. Programmable Report Limits.
R -------------------------------------------------------------------------------R ACTION RESULT R -------------------------------------------------------------------------------
R On the MCDU:
R - Push the line select key adjacent R to the < PRINT REPORT indication.
R - Push the line select key adjacent R to the < INDIVIDUAL REP PROG.
R - Enter the related report number R via the scratchpad and push the R line select key 1L.
R - Push the line select key adjacent R to the < LIMITS indication.
R - Enter the new limit value and push R the line select key adjacent to R it.
R - Push the line select key adjacent R to the < RETURN indication to get R back to the AIDS DMU PROGRAMMING R page.
R Subtask 31-36-00-740-065-A
R D. Report Counter Increment On the MCDU display:
-
The AIDS PRINT REPORT page shows.
-
The AIDS INDIV REP PROG page shows.
-
The related report number shows on the AIDS INDIV REP PROG page.
-
The AIDS REPORT LIMITS page shows.
-
The new limit value shows on the display.
-
The AIDS DMU PROGRAMMING page shows.
R -------------------------------------------------------------------------------R ACTION RESULT R -------------------------------------------------------------------------------
R On the MCDU: On the MCDU display:
R - Push the line select key adjacent - The AIDS PRINT REPORT page shows. R to the < PRINT REPORT indication.
R - Push the line select key adjacent - The AIDS INDIV REP PROG page shows. R to the < INDIVIDUAL REP PROG.
R 1EFF : 151-199, 201-210, 1 31-36-00Page 244 1 1 Aug 01/03 1 1 1CES 1
-------------------------------------------------------------------------------ACTION RESULT -------------------------------------------------------------------------------
-
Push the line select key adjacent - The AIDS REPORT COUNTERS INC page to the < COUNTERS indication. shows.
-
Push the line select key adjacent - If the increment report-counter to * YES or NO * indication to set function is set the line shows YES # the increment report-counter NO *. function. - If the increment report-counter
function is not set the line shows * YES # NO.
-
Push the line select key adjacent - The AIDS DMU PROGRAMMING MENU page to < RETURN indication to go back shows. to the AIDS DMU PROGRAMMING MENU page.
R **ON A/C 001-049, 051-099, 101-105, 151-199, 201-210,
Subtask 31-36-00-740-066
E. Programmable Statistic Counters
NOTE : On the AIDS STATISTIC COUNTERS menu you can update the APU and
____ Engine hours and cycles (AHRS, ACYC, EHRS1/2 and ECYC1/2).
(1)
To change the APU hours and cycles do the procedure (Ref. AMM TASK 31-36-00-740-004) 'Enter the APU hours and cycles data into the DMU'.
(2)
To change the engine hours and cycles do the procedure (Ref. AMM TASK 31-36-00-740-005) 'Enter the Engine hours and cycles data into the DMU'.
5. Close-up
________
Subtask 31-36-00-860-062
A. Put the system back to the serviceable condition.
(1)
De-energize the CFDS.
(2)
De-energize the aircraft electrical circuits
(Ref. TASK 24-41-00-862-002).
R 1EFF : 001-049, 051-099, 101-105, 151-199, 1 31-36-00Page 245 1201-210, 1May 01/05 1 1 1CES 1
R **ON A/C 106-149, 211-299, 301-399, 401-499,
TASK 31-36-00-740-016 FDIMU Programming Procedures
1.
Reason for the Job
__________________
Self Explanatory
2.
Job Set-up Information
______________________
中国航空网 www.aero.cn
航空翻译 www.aviation.cn
本文链接地址:A320飞机维护手册 AMM 指示/记录系统 4(3)