+---------------------------------------------------------------------+ | Value | Content Description | |--------------|------------------------------------------------------| R | X9999 | (-2000 to 20000) | R | | param. 5C.1.151.01 | R | | param. 5C.2.151.10 | R |--------------|------------------------------------------------------| R | ZLD | Landing Elevation | R | X999 | (-200 to 1400) | R | | param. 5C.1.163.01 | R | | param. 5C.2.163.10 | R |--------------|------------------------------------------------------| R | SC1 | Selected Cockpit Compt Temperature | R | 999 | (0 to 40.0 C) | R | | param. 29.1.242.01 | R | | param. 29.2.242.01 | R |--------------|------------------------------------------------------| R | SC2 | Selected FWD Cabin Compartment Temperature | R | 999 | (0 to 40.0 C) | R | | param. 29.1.244.01 | R | | param. 29.2.244.01 | R |--------------|------------------------------------------------------| R | SC3 | Selected AFT Cabin Compartment Temperature | R | 999 | (0 to 40.0 C) | R | | param. 29.1.245.01 | R | | param. 29.2.245.01 | R |--------------|------------------------------------------------------| R | RV | Trim Air Pass Reg. Valve Status | R | 1 | 1 = Closed | R | | 0 = Not Closed | R | | ZC 5D.2.060.10.20 | R |--------------|------------------------------------------------------| R | PSCW | Pressure Controller Status Word | R | XXXX | param. 5C.1.057.01 | R | | param. 5C.2.057.10 | R |--------------|------------------------------------------------------| R | VSCB | Cabin V/s | R | X9999 | (-2000 to 20000) | R | | param. 5C.1.150.01 | R | | param. 5C.2.150.10 | R |--------------|------------------------------------------------------| R | PDC | Cabin Differential Pressure | R | 999 | (-2.0 to 120 psi) | R | | param. 5C.1.144.01 | R | | param. 5C.2.144.10 | R |--------------|------------------------------------------------------| R | VF | Cabin Temperature Reg. Valve Position Group 1 |
R 1EFF : 159-199, 210-210, 1 31-37-21Page 23 1 1 May 01/05 1 1 1CES 1
+---------------------------------------------------------------------+ | Value | Content Description | |--------------|------------------------------------------------------| R | 999 | (0 to 100 %) | R | | param. 5D.2.206.10 | R |--------------|------------------------------------------------------| R | VW | Cabin Temperature Reg. Valve Position Group 2 | R | 999 | (0 to 100 %) | R | | param. 5D.2.207.10 | R |--------------|------------------------------------------------------| R | VA | Cabin Temperature Reg. Valve Position Group 3 | R | 999 | (0 to 100 %) | R | | param. 5D.2.220.10 | R |--------------|------------------------------------------------------| R | OVP | Outflow Valve Position | R | 999 | (0 to 100 %) | R | | param. 5C.1.153.01 | R | | param. 5C.2.153.10 | R |--------------|------------------------------------------------------| R | CPC | System in Control | R | 9 | 1 = System 1 in Control | R | | 2 = System 2 in Control | R | | param. 5C.1.057.01.11 = 1 System 1 in control | R | | param. 5C.2.057.10.11 = 1 System 2 in control | R +---------------------------------------------------------------------+
R **ON A/C 001-049, 051-099, 101-105, 151-158, 201-209,
(2) ECS Report Logic
+----------------------------------------------------------------------+ |Code|Item | |Progr.|Standard | | No.|No. | Description of Function Item |MCDU |Value or | | | | |GSE |Table TXY| |----|------|-----------------------------------------|------|---------| | |A | Report Format | | | | |B | Parameter Table | | | | |C | First three lines of Report | C | Blank | | |D | Print Out Rules | C | 2 | | |E | Transfer to ACARS MU | C | No | | |F | Increment of the report counter if the | C | 1 | | | | report was triggered by a code number | | | | | | > 1000; 1=yes, 0=no | | | | |G | 'Y1' second pre-events interval | C | 15 | |----|------|-----------------------------------------|------|---------| |1000|1 | Manual selection via MCDU | | |
R 1EFF : 001-049, 051-099, 101-105, 151-199, 1 31-37-21Page 24 1201-210, 1May 01/05 1 1 1CES 1 +----------------------------------------------------------------------+ |Code|Item | |Progr.|Standard | | No.|No. | Description of Function Item |MCDU |Value or | | | | |GSE |Table TXY| |----|------|-----------------------------------------|------|---------| |----|------|-----------------------------------------|------|---------| |2000|2 | Flight phase dependent manual | | | | | | selection via remote print button | | | | | | if programmed. | | | | |2.1 | Logic algorithm | | | | |2.2 | Flight Phase | C | not | |----|------|-----------------------------------------|------|---------| |3000|3 | Programmable Start Logic | | | | |3.1 | Logic algorithm | C | | | |3.2 | Logic criteria values | C | not | |----|------|-----------------------------------------|------|---------| |4000|4 | Report is generated if one of the follo-| | | | | | wing logic items is present during the | | | | | | PH 1.1 to 10: | | | |4110|4.1.1 | 5D.2.060.10.11 = 1 | C | | | | | (duct overheat warning F/D) | | | | | | or | | | |4120|4.1.2 | 5D.2.060.10.12 = 1 | C | | | | | (duct overheat warning FWD) | | | | | | or | | | |4130|4.1.3 | 5D.2.060.10.13 = 1 | C | | | | | (duct overheat warning AFT) | | | | | | or | | | |4140|4.1.4 | 5D.2.060.10.14 = 1 | C | | | | | (4 time limit exceed. duct temp F/D) | | | | | | or | | | |4150|4.1.5 | 5D.2.060.10.15 = 1 | C | | | | | (4 time limit exceed. duct temp FWD) | | | | | | or | | | |4160|4.1.6 | 5D.2.060.10.16 = 1 | C | | | | | (4 time limit exceed. duct temp AFT) | | | | | | or | | | |4210|4.2.1 | 8E.1.062.11.13 = 1 | C | | | | | (4 time pack compressor LH outlet temp. | | | | | | > 230 C) | | | | | | or | | | |4220|4.2.2 | 8E.1.062.00.13 = 1 | C | | | | | (4 time pack compressor RH outlet temp. | | | | | | > 230 C) | | | | | | or | | | |4230|4.2.3 | 8E.1.062.11.14 = 1 | C | | | | | (pack compressor LH outlet temp. > 260 C| | |
中国航空网 www.aero.cn
航空翻译 www.aviation.cn
本文链接地址:A320飞机维护手册 AMM 指示/记录系统 4(116)