R 1EFF : 106-149, 211-299, 301-399, 401-499, 1 31-37-49Page 7 1 1 Aug 01/05 1 1 1CES 1 +---------------------------------------------------------------------+ | Value | Content Description | |--------------|------------------------------------------------------| | | 18 7A.1.352.01.16 = 1 Starter Contactor Failed | | | 19 7A.1.352.01.17 = 1 Back Up Starter Cont.Failed| | | 20 7A.1.352.01.18 = 1 APU S/N Encoder Failed | | | 21 7A.1.352.01.20 = 1 Air Intake Actuator Failed | | | 22 7A.1.352.01.22 = 1 IGV LVDT Failed | | | 23 SPARE | | | 24 7A.1.037.01.11 = 1 APU Bleed Valve Open | | | 25 7A.1.037.01.12 = 1 APU Bleed Valve Closed | | | 26 7A.1.037.01.21 = 1 Main Eng. Start Mode | | | 27 SPARE | | | 28 SPARE | | | 29 SPARE | |--------------|------------------------------------------------------| | NA | APU Rotation Speed | | 9999 | (0 to 120.0 %rpm) | | | param. ECB 7A.1.176.01 | |--------------|------------------------------------------------------| | EGTA | APU Exhaust Gas Temperature | | X999 | (-50 to 1000 degrees C) | | | param. ECB 7A.1.175.01 | |--------------|------------------------------------------------------| | IGV | IGV Position | | X99 | (-14 to 90 deg) | | | param. ECB 7A.1.130.01 | |--------------|------------------------------------------------------| | P2A | APU Inlet Pressure | | 9999 | (0.1 to 1.500 bar) | | | param. ECB 7A.1.112.01 | |--------------|------------------------------------------------------| | LCIT | Load Compressor Inlet Temperature | | X999 | (-70 to 128 degrees C) | | | param. ECB 7A.1.110.01 | | | Report line V1 shows the value from previous APU | | | start. | |--------------|------------------------------------------------------| | PT | Bleed Air Pressure | | 999 | (1 to 5.00 bar) | | | param. ECB 7A.1.166.01 | |--------------|------------------------------------------------------| | WB | Bleed Air Flow | | 999 | (0.5 to 2.00 kg/sec) | | | param. ECB 7A.1.123.01 | |--------------|------------------------------------------------------| | LCDT | Load Compressor Discharge Temperature |
R 1EFF : 106-149, 211-299, 301-399, 401-499, 1 31-37-49Page 8 1 1 Aug 01/05 1 1 1CES 1 +---------------------------------------------------------------------+ | Value | Content Description | |--------------|------------------------------------------------------| | X999 | (-50 to 220 degrees C) | | | param. ECB 7A.1.074.01 | |--------------|------------------------------------------------------| | OTA | APU Oil Sump Temperature | | X99 | (-55 to 200 Degrees C) | | | param. ECB 7A.1.247.01 | |--------------|------------------------------------------------------| | GLA | APU Generator Load | | 999 | (0 to 256 %) | | | param. SDAC 29.1.100.00 | | | 29.2.100.00 | |--------------|------------------------------------------------------| | STA | APU Start Time | | 999 | (0 to 999 seconds) | | | param. DMU 0D.1.076.00 | | | APU Start Time = time from NA>1% to the moment when| | | 7A.1.037.01.22 is set to zero | |--------------|------------------------------------------------------| | EGTP | APU EGT Peak | | X999 | (-50 to 1000 Degrees C) | | | param. DMU 0D.1.074.00 | | | Highest APU EGT during APU start.Bit 7A.1.037.01.22| | | set to '1'. | |--------------|------------------------------------------------------| | NPA | NA at EGTP | | 9999 | (0 to 120.0 % rpm) | | | param. DMU 0D.1.075.00 | |--------------|------------------------------------------------------| | OTA | APU Oil Sump Temperature | | X99 | (-55 to 200 Degrees C) | | | ECB 7A.1.247.01 | | | Report line V1 indicates the value from previous | | | APU start | |--------------|------------------------------------------------------| | LCIT | Load Compressor Inlet Temperature | | X999 | (-70 to 128 Degrees C) | | | ECB 7A.1.110.01 | | | Report line V1 indicates the value from previous | | | APU start. | +---------------------------------------------------------------------+
R 1EFF : 106-149, 211-299, 301-399, 401-499, 1 31-37-49Page 9 1 1 Aug 01/05 1 1 1CES 1
R **ON A/C 159-199, 210-210,
R (1) APU MES/IDLE Report Data Field Description
R +---------------------------------------------------------------------+
R | Value | Content Description |
R |--------------|------------------------------------------------------|
R | ASN | APU Serial Number |
R | 9999 | (0 to 9999) |
R | | param. 7A.1.050.01 |
R |--------------|------------------------------------------------------|
R | AHRS | APU Operating Hours |
R | 99999 | (0 to 99999) |
R | | param. 0D.1.110.00 |
R |--------------|------------------------------------------------------|
R | ACYC | APU Start Cycles |
R | 99999 | (0 to 99999) |
中国航空网 www.aero.cn
航空翻译 www.aviation.cn
本文链接地址:A320飞机维护手册 AMM 指示/记录系统 4(123)