R 1EFF : 001-049, 051-099, 101-105, 151-199, 1 31-37-49Page 13 1201-210, 1May 01/05 1 1 1CES 1 +----------------------------------------------------------------------+ |Code|Item | |Progr.|Standard | | No.|No. | Description of Function Item |MCDU |Value or | | | | |GSE |Table TXY| |----|------|-----------------------------------------|------|---------| | | | values from the previous APU start. | | | | | | Lines N1, N2, N3, S1, S2, S3, are filled| | | | | | with values from the trigger time. | | | | |2.1 | Logic algorithm | | | | |2.2 | Flight Phase (no standard programming) | C | not | |----|------|-----------------------------------------|------|---------| |3000|3 | Programmable Start Logic | | | | |3.1 | Logic algorithm | C | | | |3.2 | Logic criteria values | C | not | |----|------|-----------------------------------------|------|---------| |4000|4 | Report is triggered once at the begin of| | | | | | each new operating hour interval 'F13.1'| | | | | | if MES is performed by an APU which had | | | | | | been started by TRU power supply. | | | | |4.1 | 'F13.1' APU operating hours interval | C | 5 | | |4.2 | MES performed 7A.1.037.01.21 = 1 | | | | | | and | | | | | | APU load control valve open | | | | | | 7A.1.037.01.11 = 1 | | | | | | and | | | | | | one engine Starter Air Valve in not | | | | | | closed | | | | | | for CFMI engines: | | | | | | 7C.1.270.01.13 = 0 XOR 7C.2.270.10.15 =0| | | | | | for IAE engines: | | | | | | 7C.1.270.01.15 = 0 XOR 7C.2.270.10.15 =0| | | | |4.3 | APU was started by TRU power if the | | | | | | previous APU start was detected by AIDS.| | | | |4.4 | The header and line E1 will be generated| | | | | | at trigger time. | | | | | | Line N1, S1 and N2, S2 are generated | | | | | | 'Y13.1' seconds after the begin of MES | | | | | | and will averaged for 'Y13.2' seconds | | | | | | (see Item No. G) except of ESN, ACW1 and| | | | | | ACW2 which are generated after the end | | | | | | of 'Y13.1' + 'Y13.2' and is not be | | | | | | averaged. | | | | |4.5 | 'Y13.1' time delay (10 seconds) | C | 10 | | |4.6 | Lines N3 and S3 are generated, when the | | | | | | APU is in idle mode. | | | | | | Master Switch off: | | | | | | 29.1.002.11.16 = 0 | | |

 

R 1EFF : 001-049, 051-099, 101-105, 151-158, 1 31-37-49Page 14

1201-209, 1May 01/05 1 1 1CES 1 +----------------------------------------------------------------------+ |Code|Item | |Progr.|Standard | | No.|No. | Description of Function Item |MCDU |Value or | | | | |GSE |Table TXY| |----|------|-----------------------------------------|------|---------| | | | and | | | | | | cooldown time 'Y13.3' is terminated | | | | | | 'Y13.3' are calculated as follows: | | | | | | The cooldown time coded in 7A.1.004.01 | | | | | | are taken and then 10 seconds are sub-| | | | | | tracted. The result is 'Y13.3'. If | | | | | | 'Y13.3' is negative, lines N3 and S3 | | | | | | are filled with zeros. | | | | | | The values are averaged for 2 seconds | | | | | | except ACW1 and ACW2. The ESN are filled| | | | | | with zeros. | | | | |4.7 | Logic algorithm | | | | |4.8 | Line V1 is contain values from the | | | | | | previous APU start performed by TRU | | | | | | power. The APU start is in progress as | | | | | | long as 7A.1.037.01.22 = 1 | | | | | | The report is only be genarated if at | | | | | | least one MES was completed. This means | | | | | | if a shutdown bit | | | | | | 7A.1.037.01.17 = 1 | | | | | | or | | | | | | 7A.1.037.01.18 = 1 | | | | | | was set during generation of the 1. MES | | | | | | lines, no report is generated. | | | | | | If the master switch is set to 'off', | | | | | | before second MES is terminated, the | | | | | | report is generated with the lines N2 | | | | | | and S2 filled with zeros. | | | |----|------|-----------------------------------------|------|---------| |8100|8.1 | ACARS MU uplink request with IMI 'REQ13'| | | | | | The report <13> is immediately generated| | | | | | and transmitted to the ACARS MU. | | | |----------------------------------------------------------------------| | AI = Programmable by Airbus Industrie | | C = Programmable by Customer | +----------------------------------------------------------------------+


R 1EFF : 001-049, 051-099, 101-105, 151-158, 1 31-37-49Page 15 1201-209, 1May 01/05 1 1 1CES 1

 

R **ON A/C 106-149, 159-199, 210-299, 301-399, 401-499,

 (2) APU MES/IDLE Report Logic
 +----------------------------------------------------------------------+ |Code|Item | |Progr.|Standard | | No.|No. | Description of Function Item |MCDU |Value or | | | | |GSE |Table TXY| |----|------|-----------------------------------------|------|---------| | |A | Report Format | | | | |B | Parameter Table | | | | |C | First three lines of Report | C | Blank | | |D | Print Out Rules | C | | | |E | Transfer to ACARS MU | C | Yes | | |F | Increment of the report counter if the | C | 1 | | | | report was triggered by a code number | | | | | | > 1000; 1=yes, 0=no | | | | |G | 'Y13.2' Average intervals for MES param.| C | 10 | |----|------|-----------------------------------------|------|---------| |1000|1 | Manual selection via MCDU | | | |----|------|-----------------------------------------|------|---------| |2000|2 | Flight phase dependent manual | | | | | | selection via remote print button | | | | | | if programmed. | | | | | | In this case the line V1 is filled with | | | | | | values from the previous APU start. | | | | | | Lines N1, N2, N3, S1, S2, S3, are filled| | | | | | with values from the trigger time. | | | | |2.1 | Logic algorithm | | | | |2.2 | Flight Phase (no standard programming) | C | not | | | | | | assigned| |----|------|-----------------------------------------|------|---------| |3000|3 | Programmable Start Logic | | | | |3.1 | Logic algorithm | C | | | |3.2 | Logic criteria values | C | not | | | | | | progr. | |----|------|-----------------------------------------|------|---------| |4000|4 | Report is triggered once at the begin of| | | | | | each new operating hour interval 'F13.1'| | | | | | if MES is performed by an APU which had | | | | | | been started by TRU power supply. | | | | |4.1 | 'F13.1' APU operating hours interval | C | 5 | | |4.2 | MES detected by DMU: | | | | | | MES performed 7A.1.037.01.21 = 1 | | | | | | and | | | | | | APU load control valve open | | |
 
中国航空网 www.aero.cn
航空翻译 www.aviation.cn
本文链接地址:A320飞机维护手册 AMM 指示/记录系统 4(126)